Small-volume and high-sensitivity NMR probes

被引:39
|
作者
Martin, Gary E. [1 ]
机构
[1] Pfizer Global Res & Dev, Michigan Struct Elucidat Grp, Kalamazoo, MI 49001 USA
关键词
D O I
10.1016/S0066-4103(05)56001-0
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Aside from efforts to develop capillary nuclear magnetic resonance (NMR) probes during the 1970s, most NMR samples were traditionally exanimed using 5 mm probes. Due to low gyromagnetic ratio and/or natural abundance, some larger format NMR probes were developed, these including 8 and 12 mm, and large volume probes of 18 and 22 mm. Large format probes addressed the difficulties of acquiring NMR data for insensitive nuclides when an investigator was not sample limited or dealing with highly insoluble materials. In contrast, for the characterization of scarce samples of natural products, impurities or degradants of pharmaceuticals, metabolites, forensic samples, and other severely sample-limited applications, even conventional 5 mm probes were not well suited to the task of acquiring data for such samples. These considerations led to the development of the first of the 3 nun NMR probes in the early 1990s followed by a succession of progressively smaller format NMR probes down to the I mm tube format probes currently available. In parallel, mu Coil probes were also developed allowing the use of still smaller sample volumes, albeit in a flow cell rather than a "tube" format, as were magic angle sideways spinning liquids probes such as the Varian Nano-probe(TM). In the late 1990s, the first examples of cryogenic NAIR probe technology became available, and these extremely high-sensitivity NAIR probes are now becoming more readily available to investigators faced with undertaking the structural characterization of scarce samples. The development of small-volume and high-sensitivity NAIR probes is described in this contribution and examples of the application of these probe technologies are reviewed.
引用
收藏
页码:1 / 96
页数:96
相关论文
共 50 条
  • [1] High-sensitivity microvolume UV absorption spectrometry for routine analysis of small-volume biological samples
    Yoo, Hee-Bong
    Yang, Inchul
    Kim, Ju Hwang
    Jung, In-Il
    Kang, Hoon
    Jung, Haewon
    Park, In-Yong
    Kim, Young Ho
    Park, Sang-Ryoul
    BIOTECHNIQUES, 2021, 70 (05)
  • [2] A SMALL-VOLUME HIGH-SPEED OSMOMETER
    BRUSS, DB
    STROSS, FH
    ANALYTICAL CHEMISTRY, 1960, 32 (11) : 1456 - 1458
  • [3] SMALL-VOLUME RESUSCITATION
    KREIMEIER, U
    MESSMER, K
    BAILLIERES CLINICAL ANAESTHESIOLOGY, 1988, 2 (03): : 545 - 577
  • [4] Small-volume cleaner
    不详
    MANUFACTURING ENGINEERING, 1999, 123 (02): : 46 - 46
  • [5] Small-volume nucleation
    Hammadi, Zoubida
    Candoni, Nadine
    Grossier, Romain
    Ildefonso, Manuel
    Morin, Roger
    Veesler, Stephane
    COMPTES RENDUS PHYSIQUE, 2013, 14 (2-3) : 192 - 198
  • [6] High-sensitivity force measurement using entangled probes
    Mancini, S
    Tombesi, P
    EUROPHYSICS LETTERS, 2003, 61 (01): : 8 - 14
  • [7] INEXPENSIVE SMALL-VOLUME PIPETING
    HENLEY, T
    MUNCHAUSEN, L
    JOURNAL OF CHEMICAL EDUCATION, 1993, 70 (12) : A311 - A311
  • [8] A small-volume microcapillary rheometer
    Salipante, Paul F.
    Kuei, Steve
    Hudson, Steven D.
    RHEOLOGICA ACTA, 2022, 61 (4-5) : 309 - 317
  • [9] ULTRASENSITIVE SMALL-VOLUME ANALYSIS
    RAMSEY, JM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 210 : 104 - ANYL
  • [10] PROBLEMS WITH SMALL-VOLUME COLUMNS
    DOLAN, JW
    LOMMEN, DC
    LC GC-MAGAZINE OF SEPARATION SCIENCE, 1990, 8 (02): : 98 - &