共 50 条
Echocardiographic assessment of β-adrenoceptor stimulation-induced heart failure with reduced heart rate in mice
被引:12
作者:
Li, Hao
[1
,2
,3
]
Lu, Zhi-Zhen
[1
,2
,3
]
Chen, Chao
[1
,2
,3
]
Song, Yao
[1
,2
,3
]
Xiao, Han
[1
,2
,3
]
Zhang, You-Yi
[1
,2
,3
]
机构:
[1] Peking Univ Third Hosp, Inst Vasc Med, Beijing 100191, Peoples R China
[2] Minist Hlth, Key Lab Cardiovasc Mol Biologyand Regulatory Pept, Beijing, Peoples R China
[3] Minist Educ, Key Lab Mol Cardiovasc Sci, Beijing, Peoples R China
来源:
CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY
|
2014年
/
41卷
/
01期
关键词:
adrenoceptor;
echocardiography;
heart failure;
heart rate;
isoflurane;
CARDIAC-HYPERTROPHY;
MYOCARDIAL-INFARCTION;
SIGNALING PATHWAY;
NERVOUS-SYSTEM;
ISOPROTERENOL;
ACTIVATION;
DISRUPTION;
ANESTHESIA;
FIBROSIS;
DISEASE;
D O I:
10.1111/1440-1681.12176
中图分类号:
R9 [药学];
学科分类号:
1007 ;
摘要:
Chronic injection with the -adrenoceptor (-AR) agonist isoproterenol (ISO) has been commonly used as an animal model of -AR-induced cardiac remodelling and heart failure. This ISO-treated model usually exhibits significantly decreased conscious heart rate (HR). However, the HR in treatment groups is usually adjusted to the same levels by anaesthesia to assess cardiac geometry and function. In the present study, we report a method of echocardiographic assessment that represents the true cardiac geometry and function under conditions of ISO withdrawal. Briefly, C57BL/6 mice were treated with 5mg/kg per day ISO for 12weeks. Cardiac geometry and function were assessed by high-resolution echocardiography in vehicle (saline) - and ISO-treated mice that were either conscious or anaesthetized using different concentrations of isoflurane. The cardiac -AR response was decreased in ISO-treated mice, as evidenced by markedly decreased conscious HR. Vehicle- and ISO-treated mice did not differ in terms of cardiac geometry or function when HR was adjusted to the same level (400b.p.m.) in both treatment groups, but cardiac geometry and function did differ when a low (1%) rather than high (1.5% or 2%) isoflurane concentration was used to adjust HR. Furthermore, 3day ISO withdrawal eliminated the difference in conscious HR between the two groups. In addition, the groups differed in cardiac geometry and function regardless of the isoflurane concentration used. In conclusion, using isoflurane to decrease the HR of treated groups to the same level may mask left ventricular dysfunction in ISO-treated mice. Withdrawal of ISO eliminated the difference in basal HR between the ISO-treated and control groups on echocardiography, allowing a more accurate assessment of cardiac pathological and functional changes.
引用
收藏
页码:58 / 66
页数:9
相关论文
共 50 条