Results of 200 Consecutive Ceramic-on-Ceramic Cementless Hip Arthroplasties in Patients Up To 50 Years of Age: A 5-24 Years of Follow-Up Study

被引:22
作者
Solarino, Giuseppe [1 ]
Zagra, Luigi [2 ]
Piazzolla, Andrea [1 ]
Morizio, Arcangelo [1 ]
Vicenti, Giovanni [1 ]
Moretti, Biagio [1 ]
机构
[1] Univ Bari Aldo Moro, AOU Policlin Consorziale, Sch Med, Dept Basic Med Sci Neurosci & Organs Sense, Bari, Italy
[2] IRCCS Ist Ortoped Galeazzi, Hip Dept, Milan, Italy
关键词
total hip arthroplasty; total hip replacement; ceramic-on-ceramic; wear; tribology; BEARING; FRACTURES; ALUMINA; REVISION; SURFACES; RISK;
D O I
10.1016/j.arth.2019.01.057
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Ceramic-on-ceramic (CoC) bearings due to their mechanical properties can be used in primary total hip arthroplasty (THA) especially in young patients requiring a long-lasting implant. The goal of this study is to analyze the results of a series of 200 consecutive CoC THAs in patients aged 50 years or less at the time of surgery. Methods: A retrospective study was conducted on the first 200 consecutive CoC arthroplasties performed using the direct lateral approach on 105 females and 81 males (14 bilateral cases) with an average age of 44.2 (16-50) years. The diagnosis was primary or post-traumatic osteoarthritis in 94 cases, avascular necrosis of the femoral head in 47, displaced intracapsular femoral neck fracture in 29, osteoarthritis secondary to developmental dysplasia of the hip/Legg-Calve-Perthes disease/slipped capital femoral epiphysis in 20, and rheumatic diseases in 10 cases. The preoperative Harris Hip Score was 32.5 on average (range 15-55). All the implants were cementless. In 177 THAs the coupling was alumina-on-alumina, and in 23 cases the coupling was AMC-on-AMC (alumina matrix composite). Results: Twenty-five patients with 28 THAs were lost at the final follow-up, 2 stems were revised due to subsidence, 1 cup was revised due to malposition, 1 femoral head was changed because of impingement, and 1 THA was revised for periprosthetic infection. Three patients sustained a Vancouver B1 periprosthetic femoral fracture. At the final follow-up (mean 14.9 years; minimum 5 years to maximum 24 years), 172 THAs were eligible for clinical and radiographic evaluation: none was revised for wear and/or breakage of the ceramic components. Harris Hip Score rose up to a mean value of 90.1 (52-100). Conclusion: The present report demonstrates that CoC coupling offers excellent long-term results in THA performed in young patients with very low wear and no adverse effects caused by the material. (c) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:S232 / S237
页数:6
相关论文
共 50 条
[21]   A 10- to 12-year follow-up study of delta ceramic-on-ceramic total hip arthroplasty [J].
Jung-Wee Park ;
Hong-Seok Kim ;
Ki-Choul Kim ;
Young-Kyun Lee ;
Yong-Chan Ha ;
Kyung-Hoi Koo .
Archives of Orthopaedic and Trauma Surgery, 2023, 143 :5385-5394
[22]   A Comparison Study of the Outcomes of Ceramic-on-Ceramic Total Hip Arthroplasty in Young vs Older Patients: A Minimum 10-Year Follow-Up Prospective Matched Study [J].
Mahiques-Segura, Gerard ;
Lizaur-Utrilla, Alejandro ;
Vizcaya-Moreno, Maria F. ;
Miralles-Munoz, Fancisco A. ;
Lopez-Prats, Fernando A. .
JOURNAL OF ARTHROPLASTY, 2019, 34 (08) :1731-1735
[23]   Outcomes of Ceramic- On-Ceramic Bearing Total Hip Arthroplasty: A Minimum 10-Year Follow-Up Study [J].
Alshammari, Malek O. ;
de Petrillo, Gianni ;
Epure, Laura M. ;
Huk, Olga L. ;
Zukor, David J. ;
Antoniou, John .
JOURNAL OF ARTHROPLASTY, 2023, 38 (07) :S146-S151
[24]   Survivorship of the cementless Spotorno femoral component in patients under 50 years of age at a mean follow-up of 18.4 years [J].
Biemond, J. E. ;
Venkatesan, S. ;
van Hellemondt, G. G. .
BONE & JOINT JOURNAL, 2015, 97B (02) :160-163
[25]   Isolated revision of an acetabular component to a ceramic-on-ceramic bearing in patients under 50 years of age [J].
Kim, Y-H. ;
Park, J-W. ;
Kim, J-S. .
BONE & JOINT JOURNAL, 2015, 97B (09) :1197-1203
[26]   32-mm ceramic-on-ceramic total hip arthroplasty versus 28-mm ceramic bearings: 5-to 15-year follow-up study [J].
Higuchi, Yoshitoshi ;
Seki, Taisuke ;
Hasegawa, Yukiharu ;
Takegami, Yasuhiko ;
Morita, Daigo ;
Ishiguro, Naoki .
HIP INTERNATIONAL, 2019, 29 (01) :65-71
[27]   Wear rates of ceramic-on-ceramic bearing surfaces in total hip implants - A 12-year follow-up study [J].
Jazrawi, LM ;
Bogner, E ;
Della Valle, CJ ;
Chen, FS ;
Pak, KI ;
Stuchin, SA ;
Frankel, VH ;
Di Cesare, PE .
JOURNAL OF ARTHROPLASTY, 1999, 14 (07) :781-787
[28]   Ceramic-on-Ceramic Total Hip Arthroplasty Using a Double Tapered, Proximally Coated Stem: 15 to 24-year Clinical and Radiologic Follow-Up [J].
Darwish, Mohammad M. ;
Bergman, Neil R. ;
Hiscock, Richard J. .
JOURNAL OF ARTHROPLASTY, 2024, 39 (09) :2323-2328
[29]   Conical Primary Cementless Stem in Revision Hip Arthroplasty: 94 Consecutive Implantations at a Mean Follow-Up of 12.7 years [J].
Romagnoli, Sergio ;
Marullo, Matteo ;
Corbella, Michele ;
Zero, Enrico ;
Parente, Andrea ;
Bargagliotti, Marco .
JOURNAL OF ARTHROPLASTY, 2021, 36 (03) :1080-1086
[30]   Ceramic-on-ceramic total hip arthroplasty is superior to metal-on-conventional polyethylene at 20-year follow-up: A randomised clinical trial [J].
Vendittoli, Pascal-Andre ;
Shahin, Maged ;
Riviere, Charles ;
Barry, Janie ;
Lavoie, Pauline ;
Duval, Nicolas .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2021, 107 (01)