Developing an electrochemical sensor for the detection of tert-butylhydroquinone

被引:65
作者
Cao, Wei [1 ]
Wang, Yong [1 ]
Zhuang, Qianfen [1 ]
Wang, Luyao [1 ]
Ni, Yongnian [1 ]
机构
[1] Nanchang Univ, Coll Chem, Nanchang 330031, Jiangxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Tert-butylhydroquinone; Electrochemistry; Manganese dioxide nanoparticles; Graphene; Ratiometric sensor; Electrodeposition; SYNTHETIC PHENOLIC ANTIOXIDANTS; EDIBLE OILS; ASCORBIC-ACID; TBHQ; NANOCOMPOSITE; REDUCTION; SUPERCAPACITOR; CHROMATOGRAPHY; EXTRACTION; ELECTRODES;
D O I
10.1016/j.snb.2019.05.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the work, a ratiometric electrochemical sensor for tert-butylhydroquinone (TBHQ) detection is constructed based on the modified electrode consisting of manganese dioxide (MnO2) and electrochemically reduced graphene oxide (ERGO) nanocomposite film. MnO2 was electrodeposited onto the electrochemically reduced graphene oxide (ERGO) placed on a glassy carbon electrode (GCE) to form the MnO2/ERGO/GCE. The construction process of the MnO2/ERGO/GCE electrode was characterized by scanning electron microscopy, energy dispersive X-ray spectroscopy, X-ray photoelectron spectroscopy, and Raman spectroscopy. The electrochemical signal responses of the TBHQ sensor were recorded by differential pulse voltammetric measurements. The experimental results demonstrate that MnO2 can be used as the inner reference electrochemical probe, and ERGO can improve the sensitivity for TBHQ detection. It can be found that as the TBHQ concentration increases, the anodic peak current of TBHQ at the MnO2 /ERGO/GCE increases, but the anodic peak current of MnO2 at such the modified electrode almost remains unchangeable. The net peak current ratio between TBHQ and MnO2 is chosen for quantitative detection of TBHQ. The developed ratiometric sensor exhibits two linear ranges of 1.0-50.0 mu M and 100.0-300.0 mu M for detecting TBHQ. The detection limit for TBHQ detection is estimated to be 0.8 mu M on the basis of signal-to-noise (S/N) of 3. Moreover, the ratiometric electrochemical sensor is successfully applied for TBHQ detection in real edible oil samples.
引用
收藏
页码:321 / 328
页数:8
相关论文
共 45 条
[21]   A novel nonenzymatic hydrogen peroxide sensor based on MnO2/graphene oxide nanocomposite [J].
Li, Limiao ;
Du, Zhifeng ;
Liu, Shuang ;
Hao, Quanyi ;
Wang, Yanguo ;
Li, Qiuhong ;
Wang, Taihong .
TALANTA, 2010, 82 (05) :1637-1641
[22]   A 3D sandwich structured hybrid of gold nanoparticles decorated MnO2/graphene-carbon nanotubes as high performance H2O2 sensors [J].
Li, Su-Juan ;
Zhang, Jing-Chao ;
Li, Juan ;
Yang, Hong-Yuan ;
Meng, Jing-Jing ;
Zhang, Bing .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 260 :1-11
[23]   Glassy carbon electrodes modified with gold nanoparticles for the simultaneous determination of three food antioxidants [J].
Lin, Xiaoyun ;
Ni, Yongnian ;
Kokot, Serge .
ANALYTICA CHIMICA ACTA, 2013, 765 :54-62
[24]   Improved Synthesis of Graphene Oxide [J].
Marcano, Daniela C. ;
Kosynkin, Dmitry V. ;
Berlin, Jacob M. ;
Sinitskii, Alexander ;
Sun, Zhengzong ;
Slesarev, Alexander ;
Alemany, Lawrence B. ;
Lu, Wei ;
Tour, James M. .
ACS NANO, 2010, 4 (08) :4806-4814
[25]   Simultaneous voltammetric determination of phenolic antioxidants in food using a boron-doped diamond electrode [J].
Medeiros, Roberta Antigo ;
Rocha-Filho, Romeu C. ;
Fatibello-Filho, Orlando .
FOOD CHEMISTRY, 2010, 123 (03) :886-891
[26]  
Michalkiewicz S., 2010, ELECTROANAL, V16, P588
[27]   Highly efficient synthesis of graphene/MnO2 hybrids and their application for ultrafast oxidative decomposition of methylene blue [J].
Qu, Jiangying ;
Shi, Lin ;
He, Chunxiang ;
Gao, Feng ;
Li, Beibei ;
Zhou, Quan ;
Hu, Han ;
Shao, Guanghua ;
Wang, Xuzhen ;
Qiu, Jieshan .
CARBON, 2014, 66 :485-492
[28]   Robust Nanocomposite of Nitrogen-Doped Reduced Graphene Oxide and MnO2 Nanorods for High-Performance Supercapacitors and Nonenzymatic Peroxide Sensors [J].
Saraf, Mohit ;
Natarajan, Kaushik ;
Mobin, Shaikh M. .
ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2018, 6 (08) :10489-10504
[29]   Voltammetric Sensor for the Determination of TBHQ in Coconut Oil [J].
Thomas, Ambily ;
Vikraman, Anuja Elevathoor ;
Thomas, Divya ;
Kumar, Krishnapillai Girish .
FOOD ANALYTICAL METHODS, 2015, 8 (08) :2028-2034
[30]   Fast simultaneous determination of BHA and TBHQ antioxidants in biodiesel by batch injection analysis using pulsed-amperometric detection [J].
Tormin, Thiago F. ;
Cunha, Rafael R. ;
Richter, Eduardo M. ;
Munoz, Rodrigo A. A. .
TALANTA, 2012, 99 :527-531