Mechanical accuracy of navigated minimally invasive total knee arthroplasty (MIS TKA)

被引:22
|
作者
Biasca, Nicola [1 ,2 ,3 ]
Wirth, Stephan [4 ]
Bungartz, Matthias [1 ,2 ,3 ]
机构
[1] Spital Oberengadin, Clin Orthoped Surg, Dept Surg, CH-7503 Samedan, St Moritz, Switzerland
[2] Spital Oberengadin, Clin Sports Med, Dept Surg, CH-7503 Samedan, St Moritz, Switzerland
[3] Spital Oberengadin, Clin Trauma Surg, Dept Surg, CH-7503 Samedan, St Moritz, Switzerland
[4] Orthoped Univ Hosp Balgrist, CH-8008 Zurich, Switzerland
来源
KNEE | 2009年 / 16卷 / 01期
关键词
Computer-assisted navigated surgery; Total knee arthroplasty; Malalignment; Malrotation; Minimally invasive surgery; COMPUTER-ASSISTED SURGERY; TIBIAL COMPONENT; ALIGNMENT; REPLACEMENT; IMPLANTATION; EXPERIENCE; STABILITY; SYSTEM;
D O I
10.1016/j.knee.2008.09.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study was designed to provide evidence that computer-navigated minimally invasive total knee arthroplasty (MIS CN-TKA) enables identical mechanical accuracy as conventional computer navigated total knee arthroplasty (CN-TKA) while reducing rehabilitation time and hospital stay of the patients. Two groups of 20 patients requiring total knee arthroplasty due to degenerative or posttraumatic knee osteoarthritis were included. Twenty consecutive patients received conventional CN-TKA and 20 consecutive patients received minimally invasive CN-TKA. Mechanical and rotational alignments were measured preoperatively and 6 months postoperatively on long-standing radiographs, on conventional coronal and sagittal views and on CT-scans of the knee. Length of skin incision, operating time, blood loss, length of hospital stay, postoperative ROM and HSS as well as KSS scores were determined. Postoperative mechanical axis improved significantly in both groups. Coronal and sagittal component positioning were accurate in both groups without significant differences. Rotational alignment showed the desired reproducible values without significant differences between the two groups. The posterior slope of the tibial component was significantly reconstructed to match the preoperative condition in both groups. The coronal alignment of the femoral and tibial components showed accurate reproducible results for implantation of both components in both groups. Length of skin incision was significantly shorter in the MIS CN-TKA. Duration of hospital stay was significantly reduced in the MIS CN-TKA group. Operating time and blood loss were similar in both groups. Postoperative ROM after the first 3 months was significantly higher in MIS CN-TKA, but after 6 months differences were minimal. Clinical outcome scores were identical for both groups 6 months after surgery. The advantages of CN-TKA are well known. Performing computer navigated TKA in combination with a minimally invasive approach in this study lead to a reduction of hospital stay and an initially increased ROM without differences in operating time and blood loss. Computer navigation in TKA preserves accurate coronal, sagittal and rotational components alignment even with a minimally invasive approach. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:22 / 29
页数:8
相关论文
共 50 条
  • [1] Minimally Invasive Computer-Navigated Total Knee Arthroplasty
    Biasca, Nicola
    Schneider, Thomas-Oliver
    Bungartz, Matthias
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2009, 40 (04) : 537 - +
  • [2] New on minimally invasive computer-assisted navigated total knee arthroplasty (MIS CA-TKA)
    Biasca, N.
    Bungartz, M.
    MINERVA ORTOPEDICA E TRAUMATOLOGICA, 2010, 61 (03) : 203 - 219
  • [3] Computer-navigated minimally invasive total knee arthroplasty for patients with retained implants in the femur
    Lin, Sung-Yen
    Chen, Chung-Hwan
    Huang, Peng-Ju
    Fu, Yin-Chih
    Huang, Hsuan-Ti
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2014, 30 (08): : 415 - 421
  • [4] Navigated total knee arthroplasty: is it error-free?
    Chua, Kerk Hsiang Zackary
    Chen, Yongsheng
    Lingaraj, Krishna
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (03) : 643 - 649
  • [5] A New Navigation System for Minimally Invasive Total Knee Arthroplasty
    Yokoyama, Yusuke
    Abe, Nobuhiro
    Fujiwara, Kazuo
    Suzuki, Masahiko
    Nakajima, Yoshikazu
    Sugita, Naohiko
    Mitsuishi, Mamoru
    Nakashima, Yoshio
    Ozaki, Toshifumi
    ACTA MEDICA OKAYAMA, 2013, 67 (06) : 351 - 358
  • [6] Hand-held navigation may improve accuracy in minimally invasive total knee arthroplasty: a prospective randomized controlled trial
    Thiengwittayaporn, Satit
    Fusakul, Yupadee
    Kangkano, Nunnapat
    Jarupongprapa, Chanintorn
    Charoenphandhu, Narattaphol
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (01) : 51 - 57
  • [7] Minimally Invasive Surgical Technique in Total Knee Arthroplasty: A Learning Curve
    Kashyap, Shankar N.
    Van Ommeren, Jan Willem
    Shankar, Sushma
    SURGICAL INNOVATION, 2009, 16 (01) : 55 - 62
  • [8] Accuracy of Implant Positioning for Minimally Invasive Total Knee Arthroplasty in Patients With Severe Varus Deformity
    Niki, Yasuo
    Matsumoto, Hideo
    Otani, Toshiro
    Enomoto, Hiroyuki
    Toyama, Yoshiaki
    Suda, Yasunori
    JOURNAL OF ARTHROPLASTY, 2010, 25 (03): : 381 - 386
  • [9] Minimally Invasive Total Knee Arthroplasty for Osteoarthritis
    Leopold, Seth S.
    NEW ENGLAND JOURNAL OF MEDICINE, 2009, 360 (17): : 1749 - 1758
  • [10] Minimally-invasive total knee arthroplasty
    Parratte, S.
    Parra, C. Garcia
    Aubaniac, J-M
    Argenson, J-N
    MINERVA ORTOPEDICA E TRAUMATOLOGICA, 2009, 60 (03) : 241 - 247