Comparison of Methods for Cleaning Enteral Feeding Tube Junctions of the New International Standard (ISO 80369-3)

被引:2
作者
Koya, Hiroaki [1 ]
Ishino, Keiko [2 ]
Kishimoto, Makoto [3 ]
Kurata, Naomi [1 ,4 ]
机构
[1] SHOWA Univ, Sch Pharm, Dept Healthcare & Regulatory Sci, Div Social Pharm, Tokyo, Japan
[2] SHOWA Univ, Sch Pharm, Dept Clin Pharm, Div Infect Control Sci, Tokyo, Japan
[3] Kirishima Med Ctr, Dept Pharm, Kagoshima, Japan
[4] SHOWA Univ, Sch Pharm, Dept Clin Pharm, Div Clin Nutr & Metab, Tokyo, Japan
关键词
ISO; 80369-3; Enteral feeding; Cleaning; Bacteria; EnClean (R); BACTERIAL-CONTAMINATION; TEMPERATURE; FORMULATION; TIME;
D O I
10.1159/000525367
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: International standards for enteral feeding involving the use of feeding tubes with junctions have been introduced. If these junctions are not properly cleaned, they can become contaminated, leading to microbial infections. We aimed to compare the ease and effectiveness of cleaning of four methods using the number of bacteria. Methods: We compared enteral nutrition tube junctions cleaned using four methods such as water, toothbrush, cotton swab, and EnClean (R) brush with an uncleaned control. Once daily for 7 days, the tubes were injected with nutrients, cleaned, and incubated at 37?. Samples for bacterial culture were collected before injections on days 7, 14, 21, and 28. The culture samples were incubated at 37? for 48 h, and the number of colonies was counted. Results: The number of residual bacteria on day 28 did not differ between the four cleaning methods and the control group. Moreover, no significant difference was observed in bacterial counts among the four wash methods. The number of washes did not differ among cleaning methods. Conclusion: The bacterial count in the ISO-standardized tube junction increased, and none of the cleaning methods decreased the counts.
引用
收藏
页码:207 / 212
页数:6
相关论文
共 17 条
  • [1] ANDERSON KR, 1984, JPEN-PARENTER ENTER, V8, P673, DOI 10.1177/0148607184008006673
  • [2] BANVILLE RR, 1966, APPL MICROBIOL, V14, P1
  • [3] BACTERIOLOGICAL QUALITY OF FABRICS WASHED AT LOWER-THAN-STANDARD TEMPERATURES IN A HOSPITAL LAUNDRY FACILITY
    CHRISTIAN, RR
    MANCHESTER, JT
    MELLOR, MT
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1983, 45 (02) : 591 - 597
  • [4] Ultrasonic system for continuous washing of textiles in liquid layers
    Gallego-Juarez, Juan A.
    Riera, Enrique
    Acosta, Victor
    Rodriguez, German
    Blanco, Alfonso
    [J]. ULTRASONICS SONOCHEMISTRY, 2010, 17 (01) : 234 - 238
  • [5] Efficacy of Electrolyzed Water and an Acidic Formulation Compared with Regularly Used Chemical Sanitizers for Tableware Sanitization during Mechanical and Manual Ware-Washing Protocols
    Handojo, Aldo
    Lee, Jaesung
    Hipp, Joel
    Pascall, Melvin A.
    [J]. JOURNAL OF FOOD PROTECTION, 2009, 72 (06) : 1315 - 1320
  • [6] Impact of wash cycle time, temperature and detergent formulation on the hygiene effectiveness of domestic laundering
    Honisch, M.
    Stamminger, R.
    Bockmuehl, D. P.
    [J]. JOURNAL OF APPLIED MICROBIOLOGY, 2014, 117 (06) : 1787 - 1797
  • [7] Jalali M, 2009, J RES MED SCI, V14, P149
  • [8] In vitro and in vivo removal of oral Candida from the denture base
    Kawasaki, Kiyotsugu
    Kamikawa, Yoshiaki
    Sugihara, Kazumasa
    [J]. GERODONTOLOGY, 2016, 33 (02) : 247 - 252
  • [9] Optimal hang time of enteral formula at standard room temperature and high temperature
    Lakananurak, Narisorn
    Nalinthassanai, Nutbordee
    Suansawang, Wanlapa
    Panarat, Palakorn
    [J]. WORLD JOURNAL OF CLINICAL CASES, 2020, 8 (19) : 4410 - 4415
  • [10] Detection and Analysis of Microbial Contamination in Museum's Con-stant Temperature and Humidity Air Conditioning System
    Li, Huixing
    Zhu, Chenyu
    Sun, Hao
    Feng, Guohui
    [J]. 10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 1179 - 1185