Identification and characterisation of Staphylococcus aureus on low cost screen printed carbon electrodes using impedance spectroscopy

被引:48
|
作者
Ward, A. C. [1 ]
Hannah, A. J. [1 ]
Kendrick, S. L. [1 ]
Tucker, N. P. [2 ]
MacGregor, G. [3 ]
Connolly, P. [1 ]
机构
[1] Univ Strathclyde, Dept Biomed Engn, Glasgow G1 1RD, Lanark, Scotland
[2] Univ Strathclyde, Strathclyde Inst Pharm & Biomed Sci, Glasgow G4 0RE, Lanark, Scotland
[3] Queen Elizabeth Univ Hosp, Dept Resp Med, 1345 Govan Rd, Glasgow G51 4TF, Lanark, Scotland
基金
英国工程与自然科学研究理事会; “创新英国”项目;
关键词
Screen printing; Impedance spectroscopy; Low cost diagnostics; Staphylococcus aureus; Rapid testing; Bacteria; BIOFILM GROWTH; EPIDEMIOLOGY;
D O I
10.1016/j.bios.2018.03.048
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Staphylococcus aureus infections are a cause of significant morbidity and mortality, in addition to representing a considerable economic burden. The aim of this study was to explore a low cost screen printed electrode as a sensor for the detection of S. aureus using impedance spectroscopy. S. aureus was incubated in chambers containing the electrodes and the results analysed using a novel normalisation approach. These results show that it is possible to detect the presence of S. aureus in LB media after 30 min incubation of a 1% growth culture, in addition to being able to see immediate cell concentration dependant changes in 0.9% NaCl. These observations imply that a number of electrochemical mechanisms cause a change in the impedance as a result of the presence of S. aureus, including adsorption to the electrode surface and the metabolism of the bacteria during growth. The study suggests that this detection approach would be useful in a number of clinical scenarios where S. aureus leads to difficult to treat infections.
引用
收藏
页码:65 / 70
页数:6
相关论文
共 24 条
  • [1] Cost Effective Soil pH Sensor Using Carbon-Based Screen-Printed Electrodes
    Singh, Mukul
    Patkar, Rajul S.
    Vinchurkar, Madhuri
    Baghini, Maryam Shojaei
    IEEE SENSORS JOURNAL, 2020, 20 (01) : 47 - 54
  • [2] Simultaneous monitoring of Staphylococcus aureus growth in a multi-parametric microfluidic platform using microscopy and impedance spectroscopy
    Estrada-Leypon, O.
    Moya, A.
    Guimera, A.
    Gabriel, G.
    Agut, M.
    Sanchez, B.
    Borros, S.
    BIOELECTROCHEMISTRY, 2015, 105 : 56 - 64
  • [3] Rapid antibiotic susceptibility testing using low-cost, commercially available screen-printed electrodes
    Hannah, Stuart
    Addington, Emily
    Alcorn, David
    Shu, Wenmiao
    Hoskisson, Paul A.
    Corrigan, Damion K.
    BIOSENSORS & BIOELECTRONICS, 2019, 145
  • [4] Redoxless Electrochemical Capacitance Spectroscopy for Investigating Surfactant Adsorption on Screen-Printed Carbon Electrodes
    Cheng, Tzong-Jih
    Hsiao, Hsien-Yi
    Tsai, Pei-Chia
    Chen, Richie L. C.
    CHEMOSENSORS, 2023, 11 (06)
  • [5] Rapid antimicrobial susceptibility testing using carbon screen printed electrodes in a microfluidic device
    Gopalakrishnan, Saranya
    Mall, Diksha
    Pushpavanam, Subramaniam
    Karmakar, Richa
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [6] Toward the development of smart and low cost point-of-care biosensors based on screen printed electrodes
    Ahmed, Minhaz Uddin
    Hossain, Mohammad Mosharraf
    Safavieh, Mohammadali
    Wong, Yen Lu
    Abd Rahman, Ibrahim
    Zourob, Mohammed
    Tamiya, Eiichi
    CRITICAL REVIEWS IN BIOTECHNOLOGY, 2016, 36 (03) : 495 - 505
  • [7] Screen printed textile electrodes using graphene and carbon nanotubes with silver for flexible supercapacitor applications
    Keawploy, Norawich
    Venkatkarthick, Radhakrishnan
    Wangyao, Panyawat
    Qin, Jiaqian
    JOURNAL OF METALS MATERIALS AND MINERALS, 2020, 30 (04): : 39 - 44
  • [8] Detection and identification of Staphylococcus aureus using magnetic particle enhanced surface plasmon spectroscopy
    Rueppel, Nadine
    Troeger, Vicky
    Sandetskaya, Natalia
    Kuhlmeier, Dirk
    Schmieder, Stefan
    Sonntag, Frank
    ENGINEERING IN LIFE SCIENCES, 2018, 18 (04): : 263 - 268
  • [9] Architecting of an aptasensor for the staphylococcus aureus analysis by modification of the screen-printed carbon electrode with aptamer/Ag-Cs-Gr QDs/NTiO2
    Ghalkhani, Masoumeh
    Sohouli, Esmail
    Khaloo, Shokooh Sadat
    Vaziri, Mohammad Hossein
    CHEMOSPHERE, 2022, 293
  • [10] Reduction of electrode polarization capacitance in low-frequency impedance spectroscopy by using mesh electrodes
    Padmaraj, Divya
    Miller, John H., Jr.
    Wosik, Jarek
    Zagozdzon-Wosik, Wanda
    BIOSENSORS & BIOELECTRONICS, 2011, 29 (01) : 13 - 17