Automated on-line comprehensive two-dimensional LC x GC and LC x GC-ToF MS: Instrument design and application to edible oil and fat analysis

被引:58
作者
de Koning, S
Janssen, HG
van Deursen, M
Brinkman, UAT
机构
[1] Unilever Res Labs, Cent Analyt Sci, NL-3130 AC Vlaardingen, Netherlands
[2] LECO Instrumente, Separat Sci Grp, D-41199 Monchengladbach, Germany
[3] Netherlands Forens Inst, NL-2280 GC Rijswijk, Netherlands
[4] Free Univ Amsterdam, Dept Analyt Chem & Appl Spect, NL-1081 HV Amsterdam, Netherlands
关键词
comprehensive two-dimensional chromatography; comprehensive LC x GC; LC x GC-ToF MS; edible fats and oils; triacylglycerides; triglycerides; TAG; fatty acid methyl esters; FAME;
D O I
10.1002/jssc.200301676
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
After a successful off-line feasibility study, the automation of comprehensively coupled liquid chromatography and gas chromatography (LC x GC) has been studied. Important aspects to consider when developing automated LG x GC include the relative speeds of the two dimensions, the compatibility of the LC eluent (type and flow rate) with the GC dimension, and the column loadabilities. Because the GC separation is relatively slow, the LC instrument has to be operated in the stop-flow mode. Two interfaces for transferring large numbers of subsequent LC fractions to the GC were constructed: one based on a six-port switching valve, and one which uses a dual side-port syringe. Both interfaces were found to perform fully acceptably. The actual transfer of the LC fraction to the GC was realised using a standard split injector to vaporise the compounds and LC eluent. Gas phase splitting was applied to match LC mass load and GC column loadability. The standard deviations of the peak areas obtained in this way were better than 7% (n = 6). The reliability of the system was demonstrated by the problem-free analysis of large series of oil and fat samples, with the focus on both intact triglycericles and their fatty acid methyl esters (FAMEs). Finally, the hyphenation of the automated LC x GC system to a sensitive and rapid-scanning time-of-flight mass spectrometer was realised. By using LC x GC-ToF MS, the information density of the chromatograms could be improved even further, which allowed easy identification of individual compounds as well as compound groups.
引用
收藏
页码:397 / 409
页数:13
相关论文
共 36 条
  • [11] REVERSED-PHASE LIQUID-CHROMATOGRAPHY COUPLED ONLINE WITH CAPILLARY GAS-CHROMATOGRAPHY .1. INTRODUCTION OF LARGE VOLUMES OF AQUEOUS MIXTURES THROUGH AN ON-COLUMN INTERFACE
    GOOSENS, EC
    DEJONG, D
    VANDENBERG, JHM
    DEJONG, GJ
    BRINKMAN, UAT
    [J]. JOURNAL OF CHROMATOGRAPHY, 1991, 552 (1-2): : 489 - 500
  • [12] ON-COLUMN INJECTION OF LARGE SAMPLE VOLUMES USING THE RETENTION GAP TECHNIQUE IN CAPILLARY GAS-CHROMATOGRAPHY
    GROB, K
    KARRER, G
    RIEKKOLA, ML
    [J]. JOURNAL OF CHROMATOGRAPHY, 1985, 334 (02): : 129 - 155
  • [13] Efficiency through combining high-performance liquid chromatography and high resolution gas chromatography: progress 1995-1999
    Grob, K
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 892 (1-2) : 407 - 420
  • [14] Holland LA, 2000, J MICROCOLUMN SEP, V12, P371, DOI 10.1002/1520-667X(2000)12:6<371::AID-MCS6>3.0.CO
  • [15] 2-N
  • [16] Direct coupling of reversed-phase liquid chromatography to gas chromatography
    Hyötyläinen, T
    Riekkola, ML
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 819 (1-2) : 13 - 24
  • [17] Comprehensive two-dimensional liquid chromatographyXgas chromatography:: evaluation of the applicability for the analysis of edible oils and fats
    Janssen, HG
    Boers, W
    Steenbergen, H
    Horsten, R
    Flöter, E
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) : 385 - 400
  • [18] Janssen HG, 2000, J MICROCOLUMN SEP, V12, P523, DOI 10.1002/1520-667X(2000)12:10<523::AID-MCS1>3.0.CO
  • [19] 2-S
  • [20] SILVER-COMPLEXATION LIQUID-CHROMATOGRAPHY FOR FAST, HIGH-RESOLUTION SEPARATIONS OF TRIACYLGLYCEROLS
    JEFFREY, BSJ
    [J]. JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1991, 68 (05) : 289 - 293