Automated on-line comprehensive two-dimensional LC x GC and LC x GC-ToF MS: Instrument design and application to edible oil and fat analysis

被引:58
|
作者
de Koning, S
Janssen, HG
van Deursen, M
Brinkman, UAT
机构
[1] Unilever Res Labs, Cent Analyt Sci, NL-3130 AC Vlaardingen, Netherlands
[2] LECO Instrumente, Separat Sci Grp, D-41199 Monchengladbach, Germany
[3] Netherlands Forens Inst, NL-2280 GC Rijswijk, Netherlands
[4] Free Univ Amsterdam, Dept Analyt Chem & Appl Spect, NL-1081 HV Amsterdam, Netherlands
关键词
comprehensive two-dimensional chromatography; comprehensive LC x GC; LC x GC-ToF MS; edible fats and oils; triacylglycerides; triglycerides; TAG; fatty acid methyl esters; FAME;
D O I
10.1002/jssc.200301676
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
After a successful off-line feasibility study, the automation of comprehensively coupled liquid chromatography and gas chromatography (LC x GC) has been studied. Important aspects to consider when developing automated LG x GC include the relative speeds of the two dimensions, the compatibility of the LC eluent (type and flow rate) with the GC dimension, and the column loadabilities. Because the GC separation is relatively slow, the LC instrument has to be operated in the stop-flow mode. Two interfaces for transferring large numbers of subsequent LC fractions to the GC were constructed: one based on a six-port switching valve, and one which uses a dual side-port syringe. Both interfaces were found to perform fully acceptably. The actual transfer of the LC fraction to the GC was realised using a standard split injector to vaporise the compounds and LC eluent. Gas phase splitting was applied to match LC mass load and GC column loadability. The standard deviations of the peak areas obtained in this way were better than 7% (n = 6). The reliability of the system was demonstrated by the problem-free analysis of large series of oil and fat samples, with the focus on both intact triglycericles and their fatty acid methyl esters (FAMEs). Finally, the hyphenation of the automated LC x GC system to a sensitive and rapid-scanning time-of-flight mass spectrometer was realised. By using LC x GC-ToF MS, the information density of the chromatograms could be improved even further, which allowed easy identification of individual compounds as well as compound groups.
引用
收藏
页码:397 / 409
页数:13
相关论文
共 50 条
  • [1] On-line LC-GC and comprehensive two-dimensional LCxGC-ToF MS for the analysis of complex samples
    Hans-Gerd Janssen
    Sjaak de Koning
    Udo A. Th. Brinkman
    Analytical and Bioanalytical Chemistry, 2004, 378 : 1944 - 1947
  • [2] On-line LC-GC and comprehensive two-dimensional LCxGC-ToF MS for the analysis of complex samples
    Janssen, HG
    de Koning, S
    Brinkman, UAT
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (08) : 1944 - 1947
  • [3] Wax ester fraction of edible oils: Analysis by on-line LC-GC-MS and GC x GC-FID
    Biedermann, Maurus
    Haase-Aschoff, Paul
    Grob, Konrad
    EUROPEAN JOURNAL OF LIPID SCIENCE AND TECHNOLOGY, 2008, 110 (12) : 1084 - 1094
  • [4] Optimization and characterization of comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometric detection (GC x GC-TOF MS)
    Dallüge, J
    Vreuls, RJJ
    Beens, J
    Brinkman, UAT
    JOURNAL OF SEPARATION SCIENCE, 2002, 25 (04) : 201 - 214
  • [5] Optimization of Headspace SPME GC x GC-TOF/MS Analysis of Volatile Organic Compounds in Edible Oils by Central Composite Design for Adulteration Detection of Edible Oil
    Sun, Yu
    Dou, Xinjing
    Yue, Xiaofeng
    Yu, Li
    Zhan, Liangxiao
    Li, Ji
    Li, Peiwu
    FOOD ANALYTICAL METHODS, 2020, 13 (06) : 1328 - 1336
  • [6] Comprehensive two-dimensional gas chromatography (GC x GC) and GC x GC-quadrupole MS analysis of Asian and American ginseng
    Shellie, RA
    Marriott, PJ
    Huie, CW
    JOURNAL OF SEPARATION SCIENCE, 2003, 26 (12-13) : 1185 - 1192
  • [7] Automated characterization of a diesel sample using comprehensive two-dimensional GC (GC X GC) and time-of-flight mass spectrometry (TOF-MS) detection
    Veriotti, T
    LC GC NORTH AMERICA, 2004, : 64 - 64
  • [8] Comprehensive two-dimensional GC (GC x GC) qMS analysis of tetrachloronaphthalenes in Halowax formulations
    Lukaszewicz, E.
    Ieda, T.
    Horii, Y.
    Yamashita, N.
    Falandysz, J.
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2007, 42 (11): : 1607 - 1614
  • [9] Detection of virgin coconut oil adulteration with animal fats using quantitative cholesterol by GC x GC-TOF/MS analysis
    Xu, Baocheng
    Li, Peiwu
    Ma, Fei
    Wang, Xiuping
    Matthaeus, Bertrand
    Chen, Ran
    Yang, Qingqing
    Zhang, Wen
    Zhang, Qi
    FOOD CHEMISTRY, 2015, 178 : 128 - 135
  • [10] Application of comprehensive two-dimensional gas chromatography (GC x GC) to the enantioselective analysis of essential oils
    Shellie, R
    Marriott, P
    Cornwell, C
    JOURNAL OF SEPARATION SCIENCE, 2001, 24 (10-11) : 823 - 830