Quantitative and simultaneous detection of two inflammation biomarkers via a fluorescent lateral flow immunoassay using dual-color SiO2@QD nanotags

被引:51
作者
Yang, Xingsheng [1 ,2 ]
Liu, Xiaoxian [1 ,2 ]
Gu, Bing [3 ]
Liu, Haifeng [1 ,2 ]
Xiao, Rui [2 ]
Wang, Chongwen [1 ,2 ,3 ,4 ]
Wang, Shengqi [2 ]
机构
[1] Anhui Agr Univ, Coll Life Sci, Hefei 230036, Peoples R China
[2] Beijing Inst Radiat Med, Beijing 100850, Peoples R China
[3] Xuzhou Med Univ, Med Technol Inst, Xuzhou 221004, Jiangsu, Peoples R China
[4] Xuzhou Med Univ, Affiliated Hosp, Dept Lab Med, Xuzhou 221004, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Dual-color SiO2@QDs; Fluorescent lateral flow immunoassay; C-reactive protein; Procalcitonin; GOLD NANOPARTICLES; SEPSIS; PROCALCITONIN; NANOSPHERES; NANOBEADS; ASSAY;
D O I
10.1007/s00604-020-04555-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-site detection strategy is reported based on dual-color SiO2@quantum dot (QD)-integrated lateral flow immunoassay (LFA) strip to realize the quantitative and simultaneous detection of C-reactive protein (CRP) and procalcitonin (PCT) in serum. The dual-color SiO2@QD nanotags with monodispersity and excellent luminescence were synthesized using polyethyleneimine-mediated electrostatic adsorption of dense red CdSe/ZnS-COOH (excitation/emission 365/625 nm) or green CdSe/ZnS-COOH (excitation/emission 365/525 nm) QDs on the surface of 180 nm SiO(2)spheres and were conjugated with anti-PCT and anti-CRP monoclonal antibodies, as stable and fluorescent-enhanced QD nanotags in the LFA system. The use of SiO2@QDs with two different fluorescent signals caused the sensitivity and specificity of the multiplex LFA system. As a result, the proposed assay provided a wide logarithmic determination range with a CRP quantitative range of 0.5-10(3) ng/mL and PCT quantitative range of 0.05-10(3) ng/mL. The limits of detection (LODs) of CRP and PCT reached 0.5 and 0.05 ng/mL, respectively. The SiO2@QD-based LFA showed great potential as rapid detection tool for the simultaneous monitoring of CRP and PCT in serum sample.
引用
收藏
页数:11
相关论文
共 46 条
[11]   Sepsis-induced immunosuppression: from cellular dysfunctions to immunotherapy [J].
Hotchkiss, Richard S. ;
Monneret, Guillaume ;
Payen, Didier .
NATURE REVIEWS IMMUNOLOGY, 2013, 13 (12) :862-874
[12]   Colorimetric-Fluorescent-Magnetic Nanosphere-Based Multimodal Assay Platform for Salmonella Detection [J].
Hu, Jiao ;
Jiang, Yong-Zhong ;
Tang, Man ;
Wu, Ling-Ling ;
Xie, Hai-yan ;
Zhang, Zhi-Ling ;
Pang, Dai-Wen .
ANALYTICAL CHEMISTRY, 2019, 91 (01) :1178-1184
[13]   Dual-Signal Readout Nanospheres for Rapid Point-of-Care Detection of Ebola Virus Glycoprotein [J].
Hu, Jiao ;
Jiang, Yong-Zhong ;
Wu, Ling-Ling ;
Wu, Zhen ;
Bi, Yuhai ;
Wong, Gary ;
Qiu, Xiangguo ;
Chen, Jianjun ;
Pang, Dai-Wen ;
Zhang, Zhi-Ling .
ANALYTICAL CHEMISTRY, 2017, 89 (24) :13105-13111
[14]   Sensitive and Quantitative Detection of C-Reaction Protein Based on Immunofluorescent Nanospheres Coupled with Lateral Flow Test Strip [J].
Hu, Jiao ;
Zhang, Zhi-Ling ;
Wen, Cong-Ying ;
Tang, Man ;
Wu, Ling-Ling ;
Liu, Cui ;
Zhu, Lian ;
Pang, Dai-Wen .
ANALYTICAL CHEMISTRY, 2016, 88 (12) :6577-6584
[15]   A novel method based on fluorescent magnetic nanobeads for rapid detection of Escherichia coli O157:H7 [J].
Huang, Zhen ;
Peng, Juan ;
Han, Jiaojiao ;
Zhang, Ganggang ;
Huang, Youju ;
Duan, Miaolin ;
Liu, Daofeng ;
Xiong, Yonghua ;
Xia, Shiqi ;
Lai, Weihua .
FOOD CHEMISTRY, 2019, 276 :333-341
[16]   Biochemical-immunological hybrid biosensor based on two-dimensional chromatography for on-site sepsis diagnosis [J].
Kim, Seung-Wan ;
Cho, Il-Hoon ;
Lim, Guei-Sam ;
Park, Gi-Na ;
Paek, Se-Hwan .
BIOSENSORS & BIOELECTRONICS, 2017, 98 :7-14
[17]   Recent advances in biosensors for diagnosis and detection of sepsis: A comprehensive review [J].
Kumar, Sanni ;
Tripathy, Suryasnata ;
Jyoti, Anupam ;
Singh, Shiv Govind .
BIOSENSORS & BIOELECTRONICS, 2019, 124 :205-215
[18]   Two-Color Lateral Flow Assay for Multiplex Detection of Causative Agents Behind Acute Febrile Illnesses [J].
Lee, Seoho ;
Mehta, Saurabh ;
Erickson, David .
ANALYTICAL CHEMISTRY, 2016, 88 (17) :8359-8363
[19]   Simultaneous fluoroimmunoassay of two tumor markers based on CdTe quantum dots and gold nanocluster coated-silica nanospheres as labels [J].
Li, Lihua ;
Feng, Dexiang ;
Zhao, Junqing ;
Guo, Zilin ;
Zhang, Yuzhong .
RSC ADVANCES, 2015, 5 (128) :105992-105998
[20]   An ultrasensitive electrochemical immunosensor for procalcitonin detection based on the gold nanoparticles-enhanced tyramide signal amplification strategy [J].
Liu, Pei ;
Li, Chao ;
Zhang, Ruixuan ;
Tang, Qing ;
Wei, Jia ;
Lu, Yan ;
Shen, Pingping .
BIOSENSORS & BIOELECTRONICS, 2019, 126 :543-550