Quantification of left ventricular indices from SSFP cine imaging: Impact of real-world variability in analysis methodology and utility of geometric modeling

被引:43
作者
Miller, Christopher A. [1 ,2 ,3 ]
Jordan, Peter [1 ]
Borg, Alex [1 ]
Argyle, Rachel [1 ]
Clark, David [4 ]
Pearce, Keith [1 ]
Schmitt, Matthias [1 ,3 ]
机构
[1] Univ S Manchester Hosp, Div Cardiol & Cardiothorac Surg, Manchester M23 9LT, Lancs, England
[2] Univ Manchester, Cardiovasc Res Grp, Manchester M13 9PL, Lancs, England
[3] Univ Manchester, Biomed Imaging Inst, Manchester M13 9PL, Lancs, England
[4] Wythenshawe CMR Unit, Alliance Med, Manchester, Lancs, England
关键词
cardiovascular magnetic resonance imaging; left ventricle; analysis methodology; geometric modeling; CARDIOVASCULAR MAGNETIC-RESONANCE; STATE FREE PRECESSION; CROSS-SECTIONAL ECHOCARDIOGRAPHY; MYOCARDIAL-INFARCTION; MATHEMATIC MODELS; EJECTION FRACTION; HEART-FAILURE; VOLUME; REPRODUCIBILITY; DYSFUNCTION;
D O I
10.1002/jmri.23892
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the impact of real-world practice variation in the process of quantifying left ventricular (LV) mass, volume indices, and ejection fraction (EF) from steady-state free precession cardiovascular magnetic resonance (CMR) images. The utility of LV geometric modeling techniques was also assessed. Materials and Methods: The effect of short-axis- versus long-axis-derived LV base identification, simplified versus detailed endocardial contouring, and visual versus automated identification of end-systole were evaluated using CMR images from 50 consecutive, prospectively recruited patients. Additionally, the performance of six geometric models was assessed. Repeated measurements were performed on 25 scans (50%) in order to assess observer variability. Results: Simplified endocardial contouring significantly overestimated volumes and underestimated EF (6 +/- 4%, P < 0.0005) compared to detailed contouring. A mean difference of 34g (P < 0.0005) was observed between mass measurements made using short-axis- versus long-axis-derived LV base positioning. A technique involving long-axis LV base identification, signal threshold-based detailed endocardial contouring, and automated identification of end-systole had significantly higher observer agreement. Geometric models showed poor agreement with conventional analysis and high variability. Conclusion: Real-world variability in CMR image analysis leads to significant differences in LV mass, volume and EF measurements, and observer variability. Appropriate reference ranges should be applied. Use of geometric models should be discouraged. J. Magn. Reson. Imaging 2013;37:12131222. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:1213 / 1222
页数:10
相关论文
共 29 条
[1]   Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences [J].
Alfakih, K ;
Plein, S ;
Thiele, H ;
Jones, T ;
Ridgway, JP ;
Sivananthan, MU .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (03) :323-329
[2]   VENTRICULAR A WAVE - NEW ECHOCARDIOGRAPHIC INDEX OF LATE DIASTOLIC FILLING OF LEFT-VENTRICLE [J].
AMBROSE, JA ;
MELLER, J ;
HERMAN, MV ;
TEICHHOLZ, LE .
AMERICAN HEART JOURNAL, 1978, 96 (05) :615-623
[3]   Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Cine MRI using steady state free precession in the radial long axis orientation is a fast accurate method for obtaining volumetric data of the left ventricle [J].
Bloomer, TN ;
Plein, S ;
Radjenovic, A ;
Higgins, DM ;
Jones, TR ;
Ridgway, JP ;
Sivananthan, MU .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (06) :685-692
[6]  
Bogaert J, 2012, CLIN CARDIAC MRI, P109
[7]   QUANTIFICATION OF THE LEFT-VENTRICULAR VOLUMES AND FUNCTION WITH CINE MR-IMAGING - COMPARISON OF GEOMETRIC-MODELS WITH 3-DIMENSIONAL DATA [J].
DULCE, MC ;
MOSTBECK, GH ;
FRIESE, KK ;
CAPUTO, GR ;
HIGGINS, CB .
RADIOLOGY, 1993, 188 (02) :371-376
[8]   TrueFISP: Assessment of accuracy for measurement of left ventricular mass in an animal model [J].
Fieno, DS ;
Jaffe, WC ;
Simonetti, OP ;
Judd, RM ;
Finn, JP .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (05) :526-531
[9]   Left ventricular mass:: Manual and automatic segmentation of true FISP and FLASH cine MR images in dogs and pigs [J].
François, CJ ;
Fieno, DS ;
Shors, SM ;
Finn, JP .
RADIOLOGY, 2004, 230 (02) :389-395
[10]   THE PROGNOSTIC ROLE OF LEFT-VENTRICULAR HYPERTROPHY IN PATIENTS WITH OR WITHOUT CORONARY-ARTERY DISEASE [J].
GHALI, JK ;
LIAO, YL ;
SIMMONS, B ;
CASTANER, A ;
CAO, GC ;
COOPER, RS .
ANNALS OF INTERNAL MEDICINE, 1992, 117 (10) :831-836