Is 24-hour Intraocular Pressure Monitoring Necessary in Glaucoma?

被引:39
作者
Mansouri, Kaweh [1 ]
Weinreb, Robert N. [1 ]
Medeiros, Felipe A. [1 ,2 ]
机构
[1] Univ Calif San Diego, Hamilton Glaucoma Ctr, Dept Ophthalmol, La Jolla, CA 92093 USA
[2] Univ Hosp Geneva, Dept Ophthalmol, Glaucoma Sect, Geneva, Switzerland
关键词
24-h monitoring; fluctuations; glaucoma; intraocular pressure; SELF-TONOMETRY; OCULAR HYPERTENSION; GOLDMANN TONOMETRY; RISK-FACTOR; PROGRESSION; FLUCTUATION; TELEMETRY; OFFICE; TERM; LATANOPROST;
D O I
10.3109/08820538.2013.771201
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Although intraocular pressure (IOP) is the only treatable risk factor for glaucoma, its 24-hour behavior is poorly understood. Conflicting information is available in the literature with regard to the importance and predictive value of IOP peaks and fluctuations on the risk of glaucoma development and progression. This may be secondary to lack of prospective studies designed to address this issue. This article critically reviews the current evidence for the importance of 24-h IOP measurements in glaucoma and discusses shortcomings of current methods to assess 24-h IOP data, drawing attention to new developments in this field.
引用
收藏
页码:157 / 164
页数:8
相关论文
共 66 条
  • [1] Continuous monitoring of circadian variations in intraocular pressure by telemetry system throughout a 12-week treatment with timolol maleate in rabbits
    Akaishi, T
    Ishida, N
    Shimazaki, A
    Hara, H
    Kuwayama, Y
    [J]. JOURNAL OF OCULAR PHARMACOLOGY AND THERAPEUTICS, 2005, 21 (06) : 436 - 444
  • [2] Alward WL, 1998, AM J OPHTHALMOL, V126, P498
  • [3] Asrani S, 2000, J GLAUCOMA, V9, P134
  • [4] Clinical utility of Intraocular pressure monitoring outside of normal office hours in patients with glaucoma
    Barkana, Yaniv
    Anis, Sarah
    Liebmann, Jeffrey
    Tello, Celso
    Ritch, Robert
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2006, 124 (06) : 793 - 797
  • [5] Fluctuation of intraocular pressure and glaucoma progression in the early manifest glaucoma trial
    Bengtsson, Boel
    Leske, M. Cristina
    Hyman, Leslie
    Heijl, Anders
    [J]. OPHTHALMOLOGY, 2007, 114 (02) : 205 - 209
  • [6] Impact of intraocular pressure regulation on visual fields in open-angle glaucoma
    Bergeå, B
    Bodin, L
    Svedbergh, B
    [J]. OPHTHALMOLOGY, 1999, 106 (05) : 997 - 1004
  • [7] Circadian fluctuation of mean ocular perfusion pressure is a consistent risk factor for normal-tension glaucoma
    Choi, Jaewan
    Kim, Kyung Hoon
    Jeong, Jinho
    Cho, Hyun-soo
    Lee, Chang Hwan
    Kook, Michael S.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (01) : 104 - 111
  • [8] Sequential office pressure measurements in the management of glaucoma
    Collaer, N
    Zeyen, TY
    Caprioli, J
    [J]. JOURNAL OF GLAUCOMA, 2005, 14 (03) : 196 - 200
  • [10] 24-Hour IOP Telemetry in the Nonhuman Primate: Implant System Performance and Initial Characterization of IOP at Multiple Timescales
    Downs, J. Crawford
    Burgoyne, Claude F.
    Seigfreid, William P.
    Reynaud, Juan F.
    Strouthidis, Nicholas G.
    Sallee, Verney
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (10) : 7365 - 7375