Characterization of prompt gamma ray emission for in vivo range verification in particle therapy: A simulation study

被引:9
作者
Zarifi, Melek [1 ]
Guatelli, Susanna [1 ]
Qi, Yujin [1 ]
Bolst, David [1 ]
Prokopovich, Dale [2 ]
Rosenfeld, Anatoly [1 ]
机构
[1] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[2] Australian Nucl Sci & Technol Org, Lucas Heights, NSW, Australia
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2019年 / 62卷
关键词
Prompt gamma; Range verification; Bragg peak tracking; Hadron therapy; Time-of-flight; ION-BEAM THERAPY; PROTON THERAPY; COMPTON CAMERA; SLIT CAMERA; BRAGG PEAK; UNCERTAINTIES; PATIENT; C-12; HE-4;
D O I
10.1016/j.ejmp.2019.04.023
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this paper we investigate the emission and detection characteristics of prompt gamma (PG) rays for in vivo range verification during hadron therapy, using Geant4 simulations. Proton, He-4 and C-12 beams of varying energy are incident on water phantoms. The PG production yield, energy spectral characteristics and spatial correlation with the Bragg Peak (BP) have been quantified. Further, the angular distributions for PG detection with respect to a point-of-reference on the phantom surface have been explored. The temporal properties of PG emission and time-of-flight (TOF) of PG detection have also been investigated in correlation with the changing particle beam range. Our results show that the primary PG rays from nuclear interactions of the primary beam exhibit the closest correlation to the beam range but its signal is significantly masked by the concurrent secondary PG rays, particularly for heavier ions such as carbon ion beams. The PG TOF spectroscopy encodes the essential information of the beam range but requires high time resolution measurements to retrieve it. A hybrid PG detection system to utilize the energy, timing and spatial characteristics of PG rays is desirable for BP tracking in real-time.
引用
收藏
页码:20 / 32
页数:13
相关论文
共 50 条
[31]   Development of integrated prompt gamma imaging and positron emission tomography system for in vivo 3-D dose verification: a Monte Carlo study [J].
Choi, Hyun Joon ;
Jang, Ji Won ;
Shin, Wook-Geun ;
Park, Hyojun ;
Incerti, Sebastien ;
Min, Chul Hee .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (10)
[32]   Assessment of Geant4 Prompt-Gamma Emission Yields in the Context of Proton Therapy Monitoring [J].
Pinto, Marco ;
Dauvergne, Denis ;
Freud, Nicolas ;
Krimmer, Jochen ;
Letang, Jean M. ;
Testa, Etienne .
FRONTIERS IN ONCOLOGY, 2016, 6
[33]   Imaging of prompt gamma rays emitted during delivery of clinical proton beams with a Compton camera: feasibility studies for range verification [J].
Polf, Jerimy C. ;
Avery, Stephen ;
Mackin, Dennis S. ;
Beddar, Sam .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (18) :7085-7099
[34]   Use of a LYSO-based Compton camera for prompt gamma range verification in proton therapy [J].
Jan, Meei-Ling ;
Hsiao, Ing-Tsung ;
Huang, Hsuan-Ming .
MEDICAL PHYSICS, 2017, 44 (12) :6261-6269
[35]   Sensitivity of a prompt-gamma slit-camera to detect range shifts for proton treatment verification [J].
Nenoff, Lena ;
Priegnitz, Marlen ;
Janssens, Guillaume ;
Petzoldt, Johannes ;
Wohlfahrt, Patrick ;
Trezza, Anna ;
Smeets, Julien ;
Pausch, Guntram ;
Richter, Christian .
RADIOTHERAPY AND ONCOLOGY, 2017, 125 (03) :534-540
[36]   Prompt-gamma imaging in particle therapy [J].
Pinto, Marco .
EUROPEAN PHYSICAL JOURNAL PLUS, 2024, 139 (10)
[37]   Prompt gamma energy integration: a new method for online-range verification in proton therapy with pulsed-beams [J].
Everaere, Pierre ;
Dauvergne, Denis ;
Gallin-Martel, Marie-Laure ;
Herault, Joel ;
Koudia, Ayoub ;
Koumeir, Charbel ;
Letang, Jean Michel ;
Testa, Etienne .
FRONTIERS IN PHYSICS, 2024, 12
[38]   Automation and uncertainty analysis of a method for in-vivo range verification in particle therapy [J].
Frey, K. ;
Unholtz, D. ;
Bauer, J. ;
Debus, J. ;
Min, C. H. ;
Bortfeld, T. ;
Paganetti, H. ;
Parodi, K. .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (19) :5903-5919
[39]   Experiment of proof-of-principle on prompt gamma-positron emission tomography (PG-PET) system for in-vivo dose distribution verification in proton therapy [J].
Cheon, Bo-Wi ;
Lee, Hyun Cheol ;
You, Sei Hwan ;
Seo, Hee ;
Min, Chul Hee ;
Choi, Hyun Joon .
NUCLEAR ENGINEERING AND TECHNOLOGY, 2023, 55 (06) :2018-2025
[40]   Prompt gamma spectroscopy for absolute range verification of 12C ions at synchrotron-based facilities [J].
Dal Bello, Riccardo ;
Martins, Paulo Magalhaes ;
Brons, Stephan ;
Hermann, German ;
Kihm, Thomas ;
Seimetz, Michael ;
Seco, Joao .
PHYSICS IN MEDICINE AND BIOLOGY, 1600, 30 (00) :2157-6564-2157-6580