Characterization of prompt gamma ray emission for in vivo range verification in particle therapy: A simulation study

被引:9
作者
Zarifi, Melek [1 ]
Guatelli, Susanna [1 ]
Qi, Yujin [1 ]
Bolst, David [1 ]
Prokopovich, Dale [2 ]
Rosenfeld, Anatoly [1 ]
机构
[1] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[2] Australian Nucl Sci & Technol Org, Lucas Heights, NSW, Australia
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2019年 / 62卷
关键词
Prompt gamma; Range verification; Bragg peak tracking; Hadron therapy; Time-of-flight; ION-BEAM THERAPY; PROTON THERAPY; COMPTON CAMERA; SLIT CAMERA; BRAGG PEAK; UNCERTAINTIES; PATIENT; C-12; HE-4;
D O I
10.1016/j.ejmp.2019.04.023
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this paper we investigate the emission and detection characteristics of prompt gamma (PG) rays for in vivo range verification during hadron therapy, using Geant4 simulations. Proton, He-4 and C-12 beams of varying energy are incident on water phantoms. The PG production yield, energy spectral characteristics and spatial correlation with the Bragg Peak (BP) have been quantified. Further, the angular distributions for PG detection with respect to a point-of-reference on the phantom surface have been explored. The temporal properties of PG emission and time-of-flight (TOF) of PG detection have also been investigated in correlation with the changing particle beam range. Our results show that the primary PG rays from nuclear interactions of the primary beam exhibit the closest correlation to the beam range but its signal is significantly masked by the concurrent secondary PG rays, particularly for heavier ions such as carbon ion beams. The PG TOF spectroscopy encodes the essential information of the beam range but requires high time resolution measurements to retrieve it. A hybrid PG detection system to utilize the energy, timing and spatial characteristics of PG rays is desirable for BP tracking in real-time.
引用
收藏
页码:20 / 32
页数:13
相关论文
共 50 条
[21]   Factors influencing the accuracy of beam range estimation in proton therapy using prompt gamma emission [J].
Janssen, F. M. F. C. ;
Landry, G. ;
Lopes, P. Cambraia ;
Dedes, G. ;
Smeets, J. ;
Schaart, D. R. ;
Parodi, K. ;
Verhaegen, F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (15) :4427-4441
[22]   Development of array-type prompt gamma measurement system for in vivo range verification in proton therapy [J].
Min, Chul Hee ;
Lee, Han Rim ;
Kim, Chan Hyeong ;
Lee, Se Byeong .
MEDICAL PHYSICS, 2012, 39 (04) :2100-2107
[23]   Prompt-gamma tomographic imaging for range verification in pencil beam-scanning proton therapy [J].
Son, J. M. ;
Oh, G. ;
Lee, J. S. ;
Kim, H. J. ;
Shin, D. S. ;
Jeong, S. H. ;
Cha, H. M. ;
Lee, H. J. ;
Lee, K. S. ;
Shin, D. H. ;
Lee, B. R. .
JOURNAL OF INSTRUMENTATION, 2025, 20 (06)
[24]   A full-scale clinical prototype for proton range verification using prompt gamma-ray spectroscopy [J].
Hueso-Gonzalez, Fernando ;
Rabe, Moritz ;
Ruggieri, Thomas A. ;
Bortfeld, Thomas ;
Verburg, Joost M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (18)
[25]   Range verification of proton radiotherapy with prompt gamma rays [J].
Lau, Andy ;
Chen, Yong ;
Ahmad, Salahuddin .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2013, 21 (04) :507-514
[26]   Validation of prompt gamma-ray spectroscopy for proton range verification in tissue-mimicking and porcine samples [J].
Tattenberg, Sebastian ;
Marants, Raanan ;
Niepel, Katharina ;
Bortfeld, Thomas ;
Sudhyadhom, Atchar ;
Landry, Guillaume ;
Parodi, Katia ;
Verburg, Joost .
PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (20)
[27]   Range verification methods in particle therapy: underlying physics and Monte Carlo modeling [J].
Kraan, Aafke Christine .
FRONTIERS IN ONCOLOGY, 2015, 5
[28]   Simulation and experimental verification of prompt gamma-ray emissions during proton irradiation [J].
Schumann, A. ;
Petzoldt, J. ;
Dendooven, P. ;
Enghardt, W. ;
Golnik, C. ;
Hueso-Gonzalez, F. ;
Kormoll, T. ;
Pausch, G. ;
Roemer, K. ;
Fiedler, F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (10) :4197-4207
[29]   A comparison of two prompt gamma imaging techniques with collimator-based cameras for range verification in proton therapy [J].
Lin, Hsin-Hon ;
Chang, Hao-Ting ;
Chao, Tsi-Chian ;
Chuang, Keh-Shih .
RADIATION PHYSICS AND CHEMISTRY, 2017, 137 :144-150
[30]   Noise evaluation of prompt-gamma technique for proton-therapy range verification using a Compton Camera [J].
Ortega, P. G. ;
Torres-Espallardo, I. ;
Boehlen, T. T. ;
Cerutti, F. ;
Chin, M. P. W. ;
Ferrari, A. ;
Gillam, J. E. ;
Lacasta, C. ;
Llosa, G. ;
Oliver, J. ;
Rafecas, M. ;
Sala, P. R. ;
Solevi, P. .
2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,