摘要
In this paper we investigate the emission and detection characteristics of prompt gamma (PG) rays for in vivo range verification during hadron therapy, using Geant4 simulations. Proton, He-4 and C-12 beams of varying energy are incident on water phantoms. The PG production yield, energy spectral characteristics and spatial correlation with the Bragg Peak (BP) have been quantified. Further, the angular distributions for PG detection with respect to a point-of-reference on the phantom surface have been explored. The temporal properties of PG emission and time-of-flight (TOF) of PG detection have also been investigated in correlation with the changing particle beam range. Our results show that the primary PG rays from nuclear interactions of the primary beam exhibit the closest correlation to the beam range but its signal is significantly masked by the concurrent secondary PG rays, particularly for heavier ions such as carbon ion beams. The PG TOF spectroscopy encodes the essential information of the beam range but requires high time resolution measurements to retrieve it. A hybrid PG detection system to utilize the energy, timing and spatial characteristics of PG rays is desirable for BP tracking in real-time.
引用
收藏
页码:20 / 32
页数:13
相关论文
共 50 条
  • [1] Characterization of prompt gamma-ray emission with respect to the Bragg peak for proton beam range verification: A Monte Carlo study
    Zarifi, Melek
    Guatelli, Susanna
    Bolst, David
    Hutton, Brian
    Rosenfeld, Anatoly
    Qi, Yujin
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 33 : 197 - 206
  • [2] A simulation study investigating a Cherenkov material for use with the prompt gamma range verification in proton therapy
    Lau, Andy
    Ahmad, Salahuddin
    Chen, Yong
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2016, 24 (04) : 565 - 582
  • [3] Spectroscopic study of prompt-gamma emission for range verification in proton therapy
    Kelleter, Laurent
    Wronska, Aleksandra
    Besuglow, Judith
    Konefal, Adam
    Laihem, Karim
    Leidner, Johannes
    Magiera, Andrzej
    Parodi, Katia
    Rusiecka, Katarzyna
    Stahl, Achim
    Tessonnier, Thomas
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 34 : 7 - 17
  • [4] In vivo range verification in particle therapy
    Parodi, Katia
    Polf, Jerimy C.
    MEDICAL PHYSICS, 2018, 45 (11) : E1036 - E1050
  • [5] Prompt gamma detection for range verification in proton therapy
    Kurosawa, Shunsuke
    Kubo, Hidetoshi
    Ueno, Kazuki
    Kabuki, Shigeto
    Iwaki, Satoru
    Takahashi, Michiaki
    Taniue, Kojiro
    Higashi, Naoki
    Miuchi, Kentaro
    Tanimori, Toru
    Kim, Dogyun
    Kim, Jongwon
    CURRENT APPLIED PHYSICS, 2012, 12 (02) : 364 - 368
  • [6] First clinical application of a prompt gamma based in vivo proton range verification system
    Richter, Christian
    Pausch, Guntram
    Barczyk, Steffen
    Priegnitz, Marlen
    Keitz, Isabell
    Thiele, Julia
    Smeets, Julien
    Stappen, Francois Vander
    Bombelli, Luca
    Fiorini, Carlo
    Hotoiu, Lucian
    Perali, Irene
    Prieels, Damien
    Enghardt, Wolfgang
    Baumann, Michael
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 (02) : 232 - 237
  • [7] Range verification of passively scattered proton beams based on prompt gamma time patterns
    Testa, Mauro
    Min, Chul Hee
    Verburg, Joost M.
    Schuemann, Jan
    Lu, Hsiao-Ming
    Paganetti, Harald
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (15) : 4181 - 4195
  • [8] Accounting for prompt gamma emission and detection for range verification in proton therapy treatment planning
    Tian, Liheng
    Huang, Ze
    Janssens, Guillaume
    Landry, Guillaume
    Dedes, George
    Kamp, Florian
    Belka, Claus
    Pinto, Marco
    Parodi, Katia
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (05)
  • [9] Compact Method for Proton Range Verification Based on Coaxial Prompt Gamma-Ray Monitoring: A Theoretical Study
    Hueso-Gonzalez, Fernando
    Bortfeld, Thomas
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2020, 4 (02) : 170 - 183
  • [10] Analytical computation of prompt gamma ray emission and detection for proton range verification
    Sterpin, E.
    Janssens, G.
    Smeets, J.
    Stappen, Francois Vander
    Prieels, D.
    Priegnitz, Marlen
    Perali, Irene
    Vynckier, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (12) : 4915 - 4946