Electrochemical sensor based on dual-template molecularly imprinted polymer and nanoporous gold leaf modified electrode for simultaneous determination of dopamine and uric acid

被引:59
|
作者
Li, Nan [1 ,2 ]
Nan, Chuanchuan [2 ,3 ]
Mei, Xuecui [4 ]
Sun, Yudong [4 ]
Feng, Huanhuan [5 ,6 ]
Li, Yingchun [4 ,7 ]
机构
[1] Jinan Univ, Stomatol Ctr, Shenzhen Peoples Hosp, Clin Med Sch 2, Shenzhen 518020, Guangdong, Peoples R China
[2] Southern Univ Sci & Technol, Affiliated Hosp 1, Shenzhen 518020, Guangdong, Peoples R China
[3] Jinan Univ, Dept ICU, Shenzhen Peoples Hosp, Clin Med Sch 2, Shenzhen 518020, Guangdong, Peoples R China
[4] Harbin Inst Technol Shenzhen, Coll Sci, Shenzhen 518055, Guangdong, Peoples R China
[5] Harbin Inst Technol Shenzhen, Sch Mat Sci & Engn, Res Ctr Printed Flexible Elect, Shenzhen 518055, Peoples R China
[6] Harbin Inst Technol Shenzhen, State Key Lab Adv Welding & Joining, Shenzhen 518055, Peoples R China
[7] Shenzhen Univ, Coll Optoelect Engn, Shenzhen 518060, Peoples R China
基金
中国国家自然科学基金;
关键词
Molecular imprinting technique; Nanomaterial; Biomarker; Electro-polymerization; Multiple targets; ASCORBIC-ACID; FABRICATION;
D O I
10.1007/s00604-020-04413-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel electrochemical sensor based on dual-template molecularly imprinted polymer (MIP) with nanoporous gold leaf (NPGL) was established for the simultaneous determination of dopamine (DA) and uric acid (UA). NPGL acts as an enlarged loading platform to enhance sensing capacity, and the MIP layer was synthesized in situ in the presence of monomer and dual templates (DA and UA) to provide specific recognition. Under the optimal conditions, the sensor shows a good linear range of 2.0 similar to 180 mu M for DA at a working potential of 0.15 V (vs. Ag/AgCl) and 5.0 similar to 160 mu M for UA at 0.35 V (vs. Ag/AgCl), with the respective detection limit of 0.3 mu M and 0.4 mu M (S/N=3). Good selectivity of the sensor to its dual templates was confirmed as the sensing signals are significantly different between templates and interfering species. The responses maintained higher than 96% of the initial values after 30-day storage, and the day-to-day relative standard deviation is less than 3.0%. Real sample simultaneous determination of DA and UA was conducted with bovine serum, and the results were in good agreement with those from high-performance liquid chromatography. It can be concluded that this work offers a reliable, facile, fast, and cost-effective method of simultaneous quantification of two or more chem-/bio-molecules.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Electrochemical sensor based on magnetic molecularly imprinted nanoparticles modified magnetic electrode for determination of Hb
    Sun, Binghua
    Ni, Xinjiong
    Cao, Yuhua
    Cao, Guangqun
    BIOSENSORS & BIOELECTRONICS, 2017, 91 : 354 - 358
  • [42] A dual-template imprinted polymer electrochemical sensor based on AuNPs and nitrogen-doped graphene oxide quantum dots coated on NiS2/biomass carbon for simultaneous determination of dopamine and chlorpromazine
    Lu, Zhiwei
    Li, Yifan
    Liu, Tao
    Wang, Guangtu
    Sun, Mengmeng
    Jiang, Yuanyuan
    He, Hua
    Wang, Yanying
    Zou, Ping
    Wang, Xianxiang
    Zhao, Qingbiao
    Rao, Hanbing
    CHEMICAL ENGINEERING JOURNAL, 2020, 389
  • [43] Dual-Template Magnetic Molecularly Imprinted Polymer for Simultaneous Determination of Spot Urine Metanephrines and 3-Methoxytyramine for the Diagnosis of Pheochromocytomas and Paragangliomas
    Zeng, Hongyu
    Zhang, Xiaoqing
    Zhen, Qianna
    He, Yifan
    Wang, Haoran
    Zhu, Yang
    Sun, Qi
    Ding, Min
    MOLECULES, 2022, 27 (11):
  • [44] An electrochemical biosensor based on nanoporous stainless steel modified by gold and palladium nanoparticles for simultaneous determination of levodopa and uric acid
    Rezaei, Behzad
    Shams-Ghahfarokhi, Leila
    Havakeshian, Elaheh
    Ensafi, Ali A.
    TALANTA, 2016, 158 : 42 - 50
  • [45] On/off-switchable electrochemical folic acid sensor based on molecularly imprinted polymer electrode
    Karimian, Najmeh
    Zavar, Mohammad Hossein Arbab
    Chamsaz, Mahmoud
    Turner, Anthony P. F.
    Tiwari, Ashutosh
    ELECTROCHEMISTRY COMMUNICATIONS, 2013, 36 : 92 - 95
  • [46] Electrochemical sensor for levofloxacin based on molecularly imprinted polypyrrole-graphene-gold nanoparticles modified electrode
    Wang, Fei
    Zhu, Lihua
    Zhang, Jingdong
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 192 : 642 - 647
  • [47] Electrochemical Determination of Tetracycline Using Molecularly Imprinted Polymer Modified Carbon Nanotube-Gold Nanoparticles Electrode
    Wang, Hongtao
    Zhao, Huimin
    Quan, Xie
    Chen, Shuo
    ELECTROANALYSIS, 2011, 23 (08) : 1863 - 1869
  • [48] Nicotinic acid voltammetric sensor based on molecularly imprinted polymer membrane-modified electrode
    Yao, Liuduan
    Tang, Youwen
    Huang, Zhaofa
    ANALYTICAL LETTERS, 2007, 40 (04) : 677 - 688
  • [49] Simultaneous Determination of Dopamine and Uric Acid using Glassy Carbon Electrode Modified with Almond-Shell-Based Nanoporous Carbon
    Baikeli, Yiliyasi
    Mamat, Xamxikamar
    Yalikun, Nuerbiya
    Wang, Ying
    Qiao, Mengfei
    Hu, Guangzhi
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (13) : B1171 - B1178
  • [50] Application of dual-template molecularly imprinted polymer-based solid phase extraction for determination of phenothiazines and benzodiazepines in swine feed
    Xia, Wan Qiu
    Cui, Peng Lei
    Wang, Geng Nan
    Liu, Jing
    Wang, Jian Ping
    ANALYTICAL METHODS, 2018, 10 (25) : 3001 - 3010