Evaluation of a Novel Wafer-Scale CMOS APS X-Ray Detector for Use in Mammography

被引:0
作者
Konstantinidis, Anastasios C. [1 ]
Zheng, Yi [1 ]
Olivo, Alessandro [1 ]
Bliznakova, Kristina [2 ]
Yip, Mary [3 ]
Anaxagoras, Thalis [4 ,5 ]
Wells, Kevin
Allinson, Nigel [5 ]
Speller, Robert D. [1 ]
机构
[1] UCL, Dept Med Phys & Bioengn, Mortimer St, London WC1E 6BT, England
[2] Tech Univ Varna, Dept Elect Engn &Microelect, Varna, Bulgaria
[3] Univ Surrey, Fac Engn Sci Phys, Surrey GU2 7XH, England
[4] ISDI Ltd, Oxford OX4 1YZ, England
[5] Lincoln Univ, Image Engn Lab, Lincoln, England
来源
2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC) | 2012年
基金
英国工程与自然科学研究理事会;
关键词
SIMULATION; SOFTWARE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The most important factors that affect the image quality are contrast, spatial resolution and noise. These factors and their relationship are quantitatively described by the Contrast-to-Noise Ratio (CNR), Signal-to-Noise Ratio (SNR), Modulation Transfer Function (MTF), Noise Power Spectrum (NPS) and Detective Quantum Efficiency (DQE) parameters. The combination of SNR, MTF and NPS determines the DQE, which represents the ability to visualize object details of a certain size and contrast at a given dose. In this study the performance of a novel large area Complementary Metal-Oxide-Semiconductor (CMOS) Active Pixel Sensor (APS) X-ray detector, called DynAMITe (Dynamic range Adjustable for Medical Imaging Technology), was investigated and compared to other three digital mammography systems (namely a) Large Area Sensor (LAS), b) Hamamatsu C9732DK, and c) Anrad SMAM), in terms of physical characteristics and evaluation of the image quality. DynAMITe detector consists of two geometrically superimposed grids: a) 2560 x 2624 pixels at 50 mu m pitch, named Sub-Pixels (SP camera) and b) 1280 x 1312 pixels at 100 mu m pitch, named Pixels (P camera). The X-ray performance evaluation of DynAMITe SP detector demonstrated high DQE results (0.58 to 0.64 at 0.5 lp/mm). Image simulation based on the X-ray performance of the detectors was used to predict and compare the mammographic image quality using ideal software phantoms: a) one representing two three dimensional (3-D) breasts of various thickness and glandularity to estimate the CNR between simulated microcalcifications and the background, and b) the CDMAM 3.4 test tool for a contrast-detail analysis of small thickness and low contrast objects. The results show that DynAMITe SP detector results in high CNR and contrast-detail performance.
引用
收藏
页码:3254 / 3260
页数:7
相关论文
共 20 条
[1]   The Multidimensional Integrated Intelligent Imaging project (MI-3) [J].
Allinson, N. ;
Anaxagoras, T. ;
Aveyard, J. ;
Arvanitis, C. ;
Bates, R. ;
Blue, A. ;
Bohndiek, S. ;
Cabello, J. ;
Chen, L. ;
Chen, S. ;
Clark, A. ;
Clayton, C. ;
Cook, E. ;
Cossins, A. ;
Crooks, J. ;
El-Gomati, M. ;
Evans, P. M. ;
Faruqi, W. ;
French, M. ;
Gow, J. ;
Greenshaw, T. ;
Greig, T. ;
Guerrini, N. ;
Harris, E. J. ;
Henderson, R. ;
Holland, A. ;
Jeyasundra, G. ;
Karadaglic, D. ;
Konstantinidis, A. ;
Liang, H. X. ;
Maini, K. M. S. ;
McMullen, G. ;
Olivo, A. ;
O'Shea, V. ;
Osmond, J. ;
Ott, R. J. ;
Prydderch, M. ;
Qiang, L. ;
Riley, G. ;
Royle, G. ;
Segneri, G. ;
Speller, R. ;
Symonds-Tayler, J. R. N. ;
Triger, S. ;
Turchetta, R. ;
Venanzi, C. ;
Wells, K. ;
Zha, X. ;
Zin, H. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (1-2) :196-198
[2]  
[Anonymous], [No title captured]
[3]  
[Anonymous], 2008, FLAT PAN SENS C9732D
[4]  
Anrad, 2004, SMAM DIG DET DIG MAM
[5]   Evaluation of an improved algorithm for producing realistic 3D breast software phantoms: Application for mammography [J].
Bliznakova, K. ;
Suryanarayanan, S. ;
Karellas, A. ;
Pallikarakis, N. .
MEDICAL PHYSICS, 2010, 37 (11) :5604-5617
[6]  
Bliznakova K, 2012, J BIOMED GRAPH COMPU, V2, P1, DOI [DOI 10.5430/JBGC.V2N1P1, 10.5430/jbgc.v2n1p1]
[7]   Characterization and Testing of LAS: A Prototype 'Large Area Sensor' With Performance Characteristics Suitable for Medical Imaging Applications [J].
Bohndiek, S. E. ;
Blue, A. ;
Cabello, J. ;
Clark, A. T. ;
Guerrini, N. ;
Evans, P. M. ;
Harris, E. J. ;
Konstantinidis, A. ;
Maneuski, D. ;
Osmond, J. ;
O'Shea, V. ;
Speller, R. D. ;
Turchetta, R. ;
Wells, K. ;
Zin, H. ;
Allinson, N. M. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (05) :2938-2946
[8]   DynAMITe: a wafer scale sensor for biomedical applications [J].
Esposito, M. ;
Anaxagoras, T. ;
Fant, A. ;
Wells, K. ;
Konstantinidis, A. ;
Osmond, J. P. F. ;
Evans, P. M. ;
Speller, R. D. ;
Allinson, N. M. .
JOURNAL OF INSTRUMENTATION, 2011, 6
[9]  
International Electrotechnical Commission, 2007, IEC- 62220-1-2
[10]  
Karssemeijer N, 1996, INT CONGR SER, V1119, P155