A mathematical method for precisely calculating the radiographic angles of the cup after total hip arthroplasty

被引:6
作者
Zhao, Jing-Xin [1 ]
Su, Xiu-Yun [1 ,2 ]
Xiao, Ruo-Xiu [3 ]
Zhao, Zhe [1 ,4 ]
Zhang, Li-Hai [1 ]
Zhang, Li-Cheng [1 ]
Tang, Pei-Fu [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Orthopaed, Beijing 100853, Peoples R China
[2] Acad Mil Med Sci, Affiliated Hosp, Dept Orthopaed, 8 Dongdajie Rd, Beijing 100071, Peoples R China
[3] Tsinghua Univ, Sch Med, Dept Biomed Engn, Beijing 100084, Peoples R China
[4] Beijing Tsinghua Chang Gung Hosp, Dept Orthopaed, 1 Block Tiantongyuan North, Beijing 102218, Peoples R China
基金
中国博士后科学基金;
关键词
Mathematics; Radiographic anteversion angle; Radiographic inclination angle; Cup; THA; PLAIN ANTEROPOSTERIOR RADIOGRAPHS; ACETABULAR CUP; SIMULATED RADIOGRAPHS; ANTEVERSION; ORIENTATION; COMPONENT; RELIABILITY; REPLACEMENT; VALIDITY; VERSION;
D O I
10.1016/j.medengphy.2016.09.007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We established a mathematical method to precisely calculate the radiographic anteversion (RA) and radiographic inclination (RI) angles of the acetabular cup based on anterior-posterior (AP) pelvic radiographs after total hip arthroplasty. Using Mathematica software, a mathematical model for an oblique cone was established to simulate how AP pelvic radiographs are obtained and to address the relationship between the two-dimensional and three-dimensional geometry of the opening circle of the cup. In this model, the vertex was the X-ray beam source, and the generatrix was the ellipse in radiographs projected from the opening circle of the acetabular cup. Using this model, we established a series of mathematical formulas to reveal the differences between the true RA and RI cup angles and the measurements results achieved using traditional methods and AP pelvic radiographs and to precisely calculate the RA and RI cup angles based on post-operative AP pelvic radiographs. Statistical analysis indicated that traditional methods should be used with caution if traditional measurements methods are used to calculate the RA and RI cup angles with AP pelvic radiograph. The entire calculation process could be performed by an orthopedic surgeon with mathematical knowledge of basic matrix and vector equations. (C) 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1376 / 1381
页数:6
相关论文
共 29 条
[1]   ANTEVERSION OF THE ACETABULAR CUP - MEASUREMENT OF ANGLE AFTER TOTAL HIP-REPLACEMENT [J].
ACKLAND, MK ;
BOURNE, WB ;
UHTHOFF, HK .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (03) :409-413
[2]   A Multiplanar Radiography Method for Assessing Cup Orientation in Total Hip Arthroplasty [J].
Amiri, Shahram ;
Masri, Bassam A. ;
Garbuz, Donald ;
Anglin, Carolyn ;
Wilson, David R. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2012, 134 (10)
[3]   A new method of measuring acetabular cup anteversion on simulated radiographs [J].
Bachhal, Vikas ;
Jindal, Nipun ;
Saini, Gaurav ;
Sament, Radheshyam ;
Kumar, Vishal ;
Chouhan, Devendra ;
Dhillon, Mandeep .
INTERNATIONAL ORTHOPAEDICS, 2012, 36 (09) :1813-1818
[4]   A New Technique for Radiographic Measurement of Acetabular Cup Orientation [J].
Derbyshire, Brian ;
Diggle, Peter J. ;
Ingham, Christopher J. ;
Macnair, Rory ;
Wimhurst, James ;
Jones, Henry Wynn .
JOURNAL OF ARTHROPLASTY, 2014, 29 (02) :369-372
[5]   Correction of acetabular cup orientation measurements for X-ray beam offset [J].
Derbyshire, Brian .
MEDICAL ENGINEERING & PHYSICS, 2008, 30 (09) :1119-1126
[6]  
Fabeck L, 1999, Acta Orthop Belg, V65, P485
[7]   EVALUATION OF ACETABULAR ANTEVERSION FOLLOWING TOTAL HIP ARTHROPLASTY - NECESSITY OF PROPER CENTERING [J].
GOERGEN, TG ;
RESNICK, D .
BRITISH JOURNAL OF RADIOLOGY, 1975, 48 (568) :259-260
[8]   Accuracy and reliability of different methods to evaluate the acetabular cup version from plain radiographs [J].
Haenle, Maximilian ;
Mittelmeier, Wolfram ;
Barbano, Rodrigo ;
Woertler, Klaus ;
Scholz, Roger ;
Bader, Rainer .
SURGICAL AND RADIOLOGIC ANATOMY, 2010, 32 (08) :725-730
[9]   RADIOGRAPHIC CALCULATION OF ANTEVERSION IN ACETABULAR PROSTHESES [J].
HASSAN, DM ;
JOHNSTON, GHF ;
DUST, WNC ;
WATSON, LG ;
CASSIDY, D .
JOURNAL OF ARTHROPLASTY, 1995, 10 (03) :369-372
[10]  
Kosiyatrakul Arkaphat, 2009, J Med Assoc Thai, V92 Suppl 6, pS128