Small specimen volume and high sample throughput are key features needed for routine methods used for population biomonitoring. We modified our routine eight-probe solid phase extraction (SPE) LC-MS/MS method for the measurement of five folate vitamers [5-methyltetrahydrofolate (5-methylTHF), folic acid (FA), plus three minor forms: THF, 5-formylTHF, 5,10-methenylTHF] and one oxidation product of 5-methylTHF (MeFox) to require less serum volume (150 mu L instead of 275 mu L) by using 96-well SPE plates with 50 mg instead of 100 mg phenyl sorbent and to provide faster throughput by using a 96-probe SPE system. Total imprecision (10 days, two replicates/day) for three serum quality control pools was 2.8-3.6 % for 5-methylTHF (19.5-51.1 nmol/L), 6.6-8.7 % for FA (0.72-11.4 nmol/L), and a parts per thousand currency sign11.4 % for the minor folate forms (< 1-5 nmol/L). The mean (+/- SE) recoveries of folates spiked into serum (3 days, four levels, two replicates/level) were: 5-methylTHF, 99.4 +/- 3.6 %; FA, 100 +/- 1.8 %; minor folates, 91.7-108 %. SPE extraction efficiencies were a parts per thousand yen85 %, except for THF (78 %). Limits of detection were a parts per thousand currency sign0.3 nmol/L. The new method correlated well with our routine method [n = 150, r = 0.99 for 5-methylTHF, FA, and total folate (tFOL, sum of folate forms)] and produced slightly higher tFOL (5.6 %) and 5-methylTHF (7.3 %) concentrations, likely due to the faster 96-probe SPE process (1 vs. 5 h), resulting in improved SPE efficiency and recovery compared to the eight-probe SPE method. With this improved LC-MS/MS method, 96 samples can be processed in similar to 2 h, and all relevant folate forms can be accurately measured using a small serum volume.
引用
收藏
页码:4549 / 4560
页数:12
相关论文
共 23 条
[1]  
[Anonymous], 2001, Guidance for industry, bioanalytical method validation
[2]   Quantification of isotope-labelled and unlabelled folates in plasma, ileostomy and food samples [J].
Buettner, Barbara E. ;
Ohrvik, Veronica E. ;
Witthoft, Cornelia M. ;
Rychlik, Michael .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (01) :429-439
[3]   Multi-rule quality control for the age-related eye disease study [J].
Caudill, Salntlel P. ;
Schleicher, Rosemary L. ;
Pirkle, James L. .
STATISTICS IN MEDICINE, 2008, 27 (20) :4094-4106
[4]   Measurement of Folates in serum and conventionally prepared whole blood lysates: Application of an automated 96-well plate isotope-dilution tandem mass spectrometry method [J].
Fazili, Z ;
Pfeiffer, CM .
CLINICAL CHEMISTRY, 2004, 50 (12) :2378-2381
[5]   Comparison of serum folate species analyzed by LC-MS/MS with total folate measured by microbiologic assay and Bio-Rad radioassay [J].
Fazili, Zia ;
Pfeiffer, Christine M. ;
Zhang, Mindy .
CLINICAL CHEMISTRY, 2007, 53 (04) :781-784
[6]   Accounting for an Isobaric Interference Allows Correct Determination of Folate Vitamers in Serum by Isotope Dilution-Liquid Chromatography-Tandem MS [J].
Fazili, Zia ;
Pfeiffer, Christine M. .
JOURNAL OF NUTRITION, 2013, 143 (01) :108-113
[7]   Proposals for setting generally applicable quality goals solely based on biology [J].
Fraser, CG ;
Petersen, PH ;
Libeer, JC ;
Ricos, C .
ANNALS OF CLINICAL BIOCHEMISTRY, 1997, 34 :8-12
[8]   Analytical Recovery of Folate Degradation Products Formed in Human Serum and Plasma at Room Temperature [J].
Hannisdal, Rita ;
Ueland, Per Magne ;
Eussen, Simone J. P. M. ;
Svardal, Asbjorn ;
Hustad, Steinar .
JOURNAL OF NUTRITION, 2009, 139 (07) :1415-1418
[9]   Liquid Chromatography-Tandem Mass Spectrometry Analysis of Folate and Folate Catabolites in Human Serum [J].
Hannisdal, Rita ;
Ueland, Per Magne ;
Svardal, Asbjorn .
CLINICAL CHEMISTRY, 2009, 55 (06) :1147-1154
[10]   Assay of whole blood (6S)-5-CH3-H4folate using ultra performance liquid chromatography tandem mass spectrometry [J].
Kirsch, Susanne H. ;
Herrmann, Wolfgang ;
Geisel, Juergen ;
Obeid, Rima .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (03) :895-902