Preliminary results of a computerized Placido disc surgical corneal topographer

被引:2
|
作者
Carvalho, LA [1 ]
Tonissi, SA [1 ]
Castro, JC [1 ]
机构
[1] Univ Calif Berkeley, Berkeley, CA 94720 USA
来源
OPHTHALMIC TECHNOLOGIES IX, PROCEEDINGS OF | 1999年 / 3591卷
关键词
corneal topography; corneal surgery; cataract; Keratoplasty;
D O I
10.1117/12.350608
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We have developed a novel instrument for computerized corneal topography during surgery. The instrument measures a region of approximately 7 mm in diameter, providing the surgeon with precise values of power and astigmatism. The system is based on a Placido Disc projecting system, which is attached to the objective lens of the surgical microscope. The Placido Disc pattern is reflected by a 50% beam splitter attached to the body of the microscope. At the beam splitter we installed our home-made adaptor and a CCD monochromatic high resolution camera. A high quality frame grabber is installed on a PC and images are digitized at a 480x640 resolution. Algorithms based on image processing techniques were implemented for edge detection of pattern. Calibrating curves based on 4 spherical surfaces were generated and approximately 3600 points were calculated for each exam. Preliminary measurements on 10 healthy corneas were compared with the measurements made on an EyeSys Corneal Topographer. Mean deviation was 0.05 for radius of curvature, 0.24 D for power and 5 degrees for cylinder. This system, with some improvements, may be successfully used to diminish high post surgical astigmatisms in surgeries such as cataract and corneal transplant. This system could also be used to gather preoperative data in corneal topography assisted LASIK.
引用
收藏
页码:53 / 62
页数:10
相关论文
共 50 条
  • [1] Repeatability and Reliability of a Combined Dual-Scheimpflug Placido Disc Corneal Topographer in Eyes with Keratoconus
    Poulsen, Anne
    Jang, Diane
    Khan, Mahmood
    Al-Mohtaseb, Zaina Nabil
    Chen, Michael
    O'Rourke, Tara
    Williams, Donald
    Banerjee, Kalins
    Zhan, Xiang
    Scott, Ingrid U.
    Pantanelli, Seth
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [2] Precision of Corneal Aberrations Measured by a New SD-OCT/Placido Topographer and Its Agreement With a Scheimpflug/Placido Topographer
    Ning, Rui
    Niu, Lingling
    Xing, Wenqian
    Wan, Ting
    Huang, Xiaomin
    Xiahou, Jinxuan
    Wang, Yiran
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Zhou, Xingtao
    Wang, Xiaoying
    Huang, Jinhai
    JOURNAL OF REFRACTIVE SURGERY, 2023, 39 (06) : 405 - +
  • [3] Comparison of Accuracy of Intraocular Lens Calculations Using Automated Keratometry, a Placido-Based Corneal Topographer, and a Combined Placido-Based and Dual Scheimpflug Corneal Topographer
    Shirayama, Mariko
    Wang, Li
    Koch, Douglas D.
    Weikert, Mitchell P.
    CORNEA, 2010, 29 (10) : 1136 - 1138
  • [4] Comparison of Color Light-Emitting Diode Corneal Topographer and Dual Rotating Scheimpflug-Placido Topographer
    Lee, Jae Hyuck
    Lee, Yong Woo
    Lee, Jong Soo
    Knorz, Michael C.
    Auffarth, Gerd U.
    Choi, Chul Young
    JOURNAL OF OPHTHALMOLOGY, 2018, 2018
  • [5] Repeatability of corneal power and wavefront aberration measurements with a dual-Scheimpflug Placido corneal topographer
    Wang, Li
    Shirayama, Mariko
    Koch, Douglas D.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (03): : 425 - 430
  • [6] Comparison of anterior segment measurements by 3 Scheimpflug tomographers and 1 Placido corneal topographer
    Savini, Giacomo
    Carbonelli, Michele
    Sbreglia, Alessandra
    Barboni, Piero
    Deluigi, Giulia
    Hoffer, Kenneth J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (09): : 1679 - 1685
  • [7] Comparison between corneal elevation maps using different reference surfaces with Scheimpflug–Placido topographer
    Engy Mohamed Mostafa
    International Ophthalmology, 2017, 37 : 553 - 558
  • [8] Dual-Scheimpflug-Placido-disc corneal analysis in cats
    de Andrade Ramos, Leticia
    Seullner Brandao, Claudia Valeria
    Guillermo Arce, Carlos
    Haddad Pinho, Renata
    Garbelotti Goncalves, Lenise
    Padovani, Carlos Roberto
    VETERINARY OPHTHALMOLOGY, 2022, 25 (05) : 360 - 366
  • [9] Corneal Power Measurement With the Dual Scheimpflug-Placido Topographer After Myopic Excimer Laser Surgery
    Pan, Chao
    Hua, Yanjun
    Huang, Jinhai
    Tan, Weina
    Lu, Weicong
    Wang, Qinmei
    JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (03) : 182 - +
  • [10] Repeatability and comparability of corneal power and corneal astigmatism obtained from a point-source color light-emitting diode topographer, a Placido-based corneal topographer, and a low-coherence reflectometer
    Ventura, Bruna V.
    Al-Mohtaseb, Zaina
    Wang, Li
    Koch, Douglas D.
    Weikert, Mitchell P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (10): : 2242 - 2250