High-precision isotopic analysis of Mg and Ca in biological samples using multi-collector ICP-mass spectrometry after their sequential chromatographic isolation - Application to the characterization of the body distribution of Mg and Ca isotopes in mice

被引:22
作者
Grigoryan, Rosa [1 ]
Costas-Rodriguez, Marta [1 ]
Vandenbroucke, Roosmarijn E. [2 ]
Vanhaecke, Frank [1 ]
机构
[1] Univ Ghent, Dept Chem, Atom & Mass Spectrometry A&MS Res Unit, Campus Sterre,Krijgslaan 281-S12, B-9000 Ghent, Belgium
[2] VIB UGent Ctr Inflammat Res, Technol Pk 71, B-9052 Ghent, Belgium
关键词
Ca isotopes; Mg isotopes; Multi-collector ICP-Mass spectrometry; Chromatographic isolation; Biofluids and tissues; Biomedical applications; PARATHYROID-HORMONE; CALCIUM; MAGNESIUM; PLASMA; SERUM; HYPOMAGNESEMIA; ELEMENTS; BLOOD; HYPOCALCEMIA; METABOLISM;
D O I
10.1016/j.aca.2020.07.045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sequential chromatographic separation procedure for subsequent high-precision isotopic analysis of Mg and Ca via multi-collector ICP-mass spectrometry (MC-ICP-MS) from a single aliquot of sample was developed and used for a variety of animal/human biofluids and tissues. The procedure consists of a one-stage Mg isolation protocol (for most of the sample types) and a three-stage isolation protocol for Ca. AG50W-X8 strong cation exchange resin was used for the isolation of Mg and Ca, while Sr-resin was used to additionally purify the Ca fraction from Sr. Potential effects on the Mg isotope ratio measurement results caused by the possible presence of concomitant matrix elements (Cu, Fe, Zn, Ca) were systematically evaluated. delta Mg-26 values were biased for a Fe/Mg ratio > 0.13 and a Ca/Mg ratio > 1.5, resulting in a shift towards a lighter Mg isotopic composition. It was shown that the Mg isotope ratio data for Mg standards, the isotopic reference materials ERM-AE143 and IRMM 009 and the biological samples investigated are located on a mass-dependent fractionation line. Biological reference materials and commercially available serum samples were analyzed for both their Mg and Ca isotope ratios. For some of the biomaterials analyzed, the Ca isotope ratio data as obtained using MC-ICP-MS were further validated via their determination using double-spike thermal ionization mass spectrometry (DS-TIMS). The expanded uncertainty for delta Mg-26 was <= 0.12 parts per thousand and for delta Ca-44/42 <= 0.29 parts per thousand. Biological fluids and tissues of mice were analyzed to characterize the body distribution of the stable isotopes of Mg and Ca. The isotopic variability among the body compartments was about 1.5 parts per thousand for Mg and 1.0 parts per thousand for Ca. Among the tissues explored, muscle tissue shows the lightest Mg and Ca isotopic compositions and liver the heaviest Mg and Ca isotopic compositions, respectively. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页码:137 / 145
页数:9
相关论文
共 49 条
  • [1] IMPAIRED RELEASE OF PARATHYROID-HORMONE IN MAGNESIUM-DEFICIENCY
    ANAST, CS
    WINNACKER, JL
    FORTE, LR
    BURNS, TW
    [J]. JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1976, 42 (04) : 707 - 717
  • [2] Anbar A., 2016, US Patent, Patent No. [PCT/US/2011/039780 US 9,261,519 B2, 9261519]
  • [3] [Anonymous], 2003, THESIS
  • [4] MG28 KINETICS IN MAN
    AVIOLI, LV
    BERMAN, M
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1966, 21 (06) : 1688 - &
  • [5] Contrasting Cu, Fe, and Zn isotopic patterns in organs and body fluids of mice and sheep, with emphasis on cellular fractionation
    Balter, Vincent
    Lamboux, Aline
    Zazzo, Antoine
    Telouk, Philippe
    Leverrier, Yann
    Marvel, Jacqueline
    Moloney, Aidan P.
    Monahan, Frank J.
    Schmidt, Olaf
    Albarede, Francis
    [J]. METALLOMICS, 2013, 5 (11) : 1470 - 1482
  • [6] Chromatographic purification of Ca and Mg from biological and geological samples for isotope analysis by MC-ICP-MS
    Bao, Zhian
    Zong, Chunlei
    Chen, Kaiyun
    Lv, Nan
    Yuan, Honglin
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2020, 448
  • [7] Protective effect of calcium deficiency on the inflammatory response in magnesium-deficient rats
    Bussière, FI
    Gueux, E
    Rock, E
    Mazur, A
    Rayssiguier, Y
    [J]. EUROPEAN JOURNAL OF NUTRITION, 2002, 41 (05) : 197 - 202
  • [8] A revisited method for Mg purification and isotope analysis using cool-plasma MC-ICP-MS
    Choi, Min Seok
    Ryu, Jong-Sik
    Lee, Sin-Woo
    Shin, Hyung Seon
    Lee, Kwang-Sik
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (11) : 1955 - 1959
  • [9] Establishing the potential of Ca isotopes as proxy for consumption of dairy products
    Chu, Nan-Chin
    Henderson, Gideon M.
    Belshaw, Nick S.
    Hedges, Robert E. M.
    [J]. APPLIED GEOCHEMISTRY, 2006, 21 (10) : 1656 - 1667
  • [10] Body distribution of stable copper isotopes during the progression of cholestatic liver disease induced by common bile duct ligation in mice
    Costas-Rodriguez, Marta
    Van Campenhout, Sanne
    Hastuti, Agustina A. M. B.
    Devisscher, Lindsey
    Van Vlierberghe, Hans
    Vanhaecke, Frank
    [J]. METALLOMICS, 2019, 11 (06) : 1093 - 1103