Within-day and between-day variability of transthoracic anatomic M-mode echocardiography in the awake bottlenose dolphin (Tursiops truncatus)

被引:11
作者
Chetboul, Valerie [1 ,2 ]
Lichtenberger, Jonathan [1 ]
Mellin, Mathieu [3 ]
Mercera, Birgitta [3 ]
Hoffmann, Anne-Cecile [1 ]
Chaix, Gwendoline [1 ]
Trehiou-Sechi, Emilie [1 ]
Misbach, Charlotte [1 ]
Petit, Amandine [1 ]
Lefebvre, Herve P. [4 ]
Gaide, Nicolas [1 ]
Tissier, Renaud [2 ,5 ]
Delfour, Fabienne [3 ]
机构
[1] Univ Paris Est, Ecole Natl Vet Alfort, CHUVA, UCA, F-94704 Maisons Alfort, France
[2] Hop Henri Mondor, INSERM, U955, Equipe 03, F-94010 Creteil, France
[3] Delphinarium Parc Asterix, Plailly, France
[4] Ecole Natl Vet Toulouse, Unite Rech Clin Sante Populat, F-31076 Toulouse 03, France
[5] Univ Paris Est, Ecole Natl Vet Alfort, Unite Pharm Toxicol, F-94704 Maisons Alfort, France
关键词
Aquatic mammal; Heart; Repeatability; Reproducibility; DIVING BRADYCARDIA; SYSTOLIC FUNCTION; DISEASE; REPRODUCIBILITY; REPEATABILITY; OBSERVER; SIZE; DOGS;
D O I
10.1016/j.jvc.2012.07.002
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The use of transthoracic echocardiography in dolphins has been limited so far owing to technical and anatomical specificities. Anatomic M-mode (AMM) is a postprocessing echocardiographie technique generating M-mode studies from two-dimensional (2D) cineloops independently of the ultrasound beam orientation. The aim of the present study was to determine the within-day (repeatability) and between-day (reproducibility) variability of AMM echocardiography in awake healthy bottlenose dolphins (BN, Tursiops truncatus). Four adult BN trained to lie in left recumbency at the water surface were involved in the protocol. A total of 96 echocardiographic examinations were performed on 4 different days by a trained observer examining each BN 6 times per day. Video clips of 2D left parasternal long-axis views showing the left ventricle (LV) ventrally and the aortic root dorsally were recorded at each examination and analyzed for AMM measurements in a random order. A general linear model was used to determine the within-day and between-day coefficients of variation (CV). All examinations were interpretable allowing calculation of 10 AMM variables (i.e., end-diastolic and end-systolic ventral and dorsal LV myocardial wall thicknesses as well as LV and aortic diameters, mean aortic diameter, and LV shortening fraction). Most within- and between-day CV values (18/20) were <15%, the lowest being observed for the end-diastolic LV diameter (1.6%). In conclusion, AMM provides a simple noninvasive evaluation of heart morphology and function in the awake BN with good repeatability and reproducibility of the measurements. Further studies are required to determine the corresponding reference intervals. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:511 / 518
页数:8
相关论文
共 25 条
  • [11] 2
  • [12] Anatomic M-mode, a pertinent tool for the daily practice of transthoracic echocardiography
    Donal, E
    Coisne, D
    Pham, B
    Ragot, S
    Herpin, D
    Thomas, JD
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2004, 17 (09) : 962 - 967
  • [13] DIVING BRADYCARDIA IN TRAINED DOLPHIN
    ELSNER, R
    KENNEY, DW
    BURGESS, K
    [J]. NATURE, 1966, 212 (5060) : 407 - &
  • [14] Pathology of Striped Dolphins (Stenella coeruleoalba) Infected with Brucella ceti
    Gonzalez-Barrientos, R.
    Morales, J-A.
    Hernandez-Mora, G.
    Barquero-Calvo, E.
    Guzman-Verri, C.
    Chaves-Olarte, E.
    Moreno, E.
    [J]. JOURNAL OF COMPARATIVE PATHOLOGY, 2010, 142 (04) : 347 - 352
  • [15] Quantification of mitral valve regurgitation in dogs with degenerative mitral valve disease by use of the proximal isovelocity surface area method
    Gouni, Vassiliki
    Serres, Francois J.
    Pouchelon, Jean-Louis
    Tissier, Renaud
    Lefebvre, Herve R.
    Nicolle, Audrey P.
    Sampedrano, Carolina Carlos
    Chetboul, Valerie
    [J]. JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2007, 231 (03): : 399 - 406
  • [16] Grenacher Patrizia A, 2010, J Vet Cardiol, V12, P111, DOI 10.1016/j.jvc.2010.01.002
  • [17] Gulland FMD, 2001, CRC HANDBOOK OF MARINE MAMMAL MEDICINE, SECOND EDITION, P521
  • [18] MORBILLIVIRAL DISEASE IN AN ATLANTIC BOTTLE-NOSED-DOLPHIN (TURSIOPS-TRUNCATUS) FROM THE GULF-OF-MEXICO
    LIPSCOMB, TP
    KENNEDY, S
    MOFFETT, D
    FORD, BK
    [J]. JOURNAL OF WILDLIFE DISEASES, 1994, 30 (04) : 572 - 576
  • [19] Anatomic M-mode: A new technique for quantitative assessment of left ventricular size and function
    Mele, D
    Pedini, I
    Alboni, P
    Levine, RA
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (12A) : 82G - 85G
  • [20] The development of diving bradycardia in bottlenose dolphins (Tursiops truncatus)
    Noren, SR
    Cuccurullo, V
    Williams, TM
    [J]. JOURNAL OF COMPARATIVE PHYSIOLOGY B-BIOCHEMICAL SYSTEMIC AND ENVIRONMENTAL PHYSIOLOGY, 2004, 174 (02) : 139 - 147