Seismic design and performance of dry-assembled precast structures with adaptable joints

被引:49
作者
Dal Lago, Bruno [1 ]
Negro, Paolo [2 ]
Dal Lago, Alberto [3 ]
机构
[1] Politecn Milan, Dept Civil & Environm Engn, Milan, Italy
[2] European Commiss, Joint Res Ctr, Via Enrico Fermi 2749, I-21027 Ispra, VA, Italy
[3] DLC Consulting, Milan, Italy
关键词
Precast structures; Joint adaptation; mechanical connections; Dry joints; Seismic performance; Non-linear analysis; Full-scale testing; INDUSTRIAL BUILDINGS; DISSIPATIVE DEVICES; CONCRETE BUILDINGS; CYCLIC RESPONSE; CLADDING PANELS; CONNECTIONS; BEHAVIOR; EARTHQUAKE; RETROFIT; WALL;
D O I
10.1016/j.soildyn.2017.12.016
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Previous research projects and post-earthquake field observation showed that dry-assembled precast frame structures with hinged beams and cantilever columns restrained at their base, if correctly designed and detailed, can attain good seismic performance, mainly due to their flexibility and robustness. Their seismic design is often conditioned by the need of reducing their flexibility by increasing the cross-section of the columns, which, due to minimum reinforcement requirements, results in their over-strengthening. High flexibility may also induce displacement compatibility issues with non-structural elements. The paper concerns the proposal of an innovative enhanced structural frame system, based on the adaptation of hinged beam-column joints into rigid through the activation of special mechanical connection devices performed after the installation of the slab. While keeping all the benefits of the dry prefabrication, the resulting moment-resisting frame is provided with enhanced redundancy and stiffness. A design comparison among three precast frames with similar geometries and different static schemes shows how the joint adaptation can be exploited to optimise the structure by modifying the distribution of bending moment. The results of dynamic non-linear analyses on a three-storey precast structure with adaptable joints tested as a part of the SAFECAST research programme show the seismic performance of this system through different static schemes, and the comparison with the experimental results provides information about the validity of the models and the effectiveness of the technological solutions employed.
引用
收藏
页码:182 / 195
页数:14
相关论文
共 62 条
[1]  
[Anonymous], 2010, Model Code for Concrete Structures 2010 (MC2010)
[2]  
[Anonymous], 2004, EUROCODE 8 DESIGN ST
[3]  
[Anonymous], 1970, J STRUCT DIV ASCE
[4]  
[Anonymous], 2008, NTC2008 IT MIN INFR
[5]  
[Anonymous], 2004, 19911 EN
[6]   Seismic fragility functions of industrial precast building classes [J].
Babic, Anze ;
Dolsek, Matjaz .
ENGINEERING STRUCTURES, 2016, 118 :357-370
[7]   Seismic Performance of Precast Industrial Facilities Following Major Earthquakes in the Italian Territory [J].
Belleri, A. ;
Brunesi, E. ;
Nascimbene, R. ;
Pagani, M. ;
Riva, P. .
JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2015, 29 (05)
[8]   Dissipating and re-centring devices for portal-frame precast structures [J].
Belleri, Andrea ;
Marini, Alessandra ;
Riva, Paolo ;
Nascimbene, Roberto .
ENGINEERING STRUCTURES, 2017, 150 :736-745
[9]   Horizontal cladding panels: in-plane seismic performance in precast concrete buildings [J].
Belleri, Andrea ;
Torquati, Mauro ;
Marini, Alessandra ;
Riva, Paolo .
BULLETIN OF EARTHQUAKE ENGINEERING, 2016, 14 (04) :1103-1129
[10]   Vulnerability assessment and retrofit solutions of precast industrial structures [J].
Belleri, Andrea ;
Torquati, Mauro ;
Riva, Paolo ;
Nascimbene, Roberto .
EARTHQUAKES AND STRUCTURES, 2015, 8 (03) :801-820