Magnetic Particle Imaging: A Resovist Based Marking Technology for Guide Wires and Catheters for Vascular Interventions

被引:38
作者
Haegele, Julian [1 ]
Panagiotopoulos, Nikolaos [1 ]
Cremers, Sjef [2 ]
Rahmer, Juergen [3 ]
Franke, Jochen [4 ]
Duschka, Robert L. [1 ,5 ]
Vaalma, Sarah [1 ]
Heidenreich, Michael [4 ]
Borgert, Joern [3 ]
Borm, Paul [2 ]
Barkhausen, Joerg [1 ]
Vogt, Florian M. [1 ]
机构
[1] Univ Hosp Schleswig Holstein, Dept Radiol & Nucl Med, D-23538 Lubeck, Germany
[2] Nano4Imaging GmbH, D-52074 Aachen, Germany
[3] Philips Technol GmbH Innovat Technol, Res Labs, D-22315 Hamburg, Germany
[4] Bruker Biospin MRI GmbH, D-76275 Ettlingen, Germany
[5] Radiol Allianz GbR, D-20095 Hamburg, Germany
关键词
Magnetic particle imaging; SPIO-coating; superparamagnetic iron oxide nanoparticles; vascular intervention; CARDIOVASCULAR INTERVENTIONS; RECONSTRUCTION; VISUALIZATION; INSTRUMENTS; MPI;
D O I
10.1109/TMI.2016.2559538
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Magnetic particle imaging (MPI) is able to provide high temporal and good spatial resolution, high signal to noise ratio and sensitivity. Furthermore, it is a truly quantitative method as its signal strength is proportional to the concentration of its tracer, superparamagnetic iron oxide nanoparticles (SPIOs), over a wide range practically relevant concentrations. Thus, MPI is proposed as a promising future method for guidance of vascular interventions. To implement this, devices such as guide wires and catheters have to be discernible in MPI, which can be achieved by coating already commercially available devices with SPIOs. In this proof of principle study the feasibility of that approach is demonstrated. First, a Ferucarbotran-based SPIO-varnish was developed by embedding Ferucarbotran into an organic based solvent. Subsequently, the biocompatible varnish was applied to a commercially available guidewire and diagnostic catheter for vascular interventional purposes. In an interventional setting using a vessel phantom, the coating proved to be mechanically and chemically stable and thin enough to ensure normal handling as with uncoated devices. The devices were visualized in 3D on a preclinical MPI demonstrator using a system function based image reconstruction process. The system function was acquired with a probe of the dried varnish prior to the measurements. The devices were visualized with a very high temporal resolution and a simple catheter/guide wire maneuver was demonstrated.
引用
收藏
页码:2312 / 2318
页数:7
相关论文
共 34 条
[1]   Perspectives on clinical magnetic particle imaging [J].
Borgert, Joern ;
Schmidt, Joachim D. ;
Schmale, Ingo ;
Bontus, Claas ;
Gleich, Bernhard ;
David, Bernd ;
Weizenecker, Juergen ;
Jockram, Jonas ;
Lauruschkat, Christian ;
Mende, Oliver ;
Heinrich, Mathias ;
Halkola, Aleksi ;
Bergmann, Joern ;
Woywode, Oliver ;
Rahmer, Juergen .
BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58 (06) :551-556
[2]   Fundamentals and applications of magnetic particle imaging [J].
Borgert, Joern ;
Schmidt, Joachim D. ;
Schmale, Ingo ;
Rahmer, Juergen ;
Bontus, Claas ;
Gleich, Bernhard ;
David, Bernd ;
Eckart, Rainer ;
Woywode, Oliver ;
Weizenecker, Juergen ;
Schnorr, Joerg ;
Taupitz, Matthias ;
Haegele, Julian ;
Vogt, Florian M. ;
Barkhausen, Joerg .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (03) :149-153
[3]  
Bringout G., 2013, INT WORKSH MAGN PART
[4]   Magnetic particle imaging: Introduction to imaging and hardware realization [J].
Buzug, Thorsten M. ;
Bringout, Gael ;
Erbe, Marlitt ;
Graefe, Ksenija ;
Graeser, Matthias ;
Gruettner, Mandy ;
Halkola, Aleksi ;
Sattel, Timo F. ;
Tenner, Wiebke ;
Wojtczyk, Hanne ;
Haegele, Julian ;
Vogt, Florian M. ;
Barkhausen, Joerg ;
Luedtke-Buzug, Kerstin .
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2012, 22 (04) :323-334
[6]   Safety considerations for magnetic fields of 10 mT to 100 mT amplitude in the frequency range of 10 kHz to 100 kHz for magnetic particle imaging [J].
Doessel, Olaf ;
Bohnert, Julia .
BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58 (06) :611-621
[7]   Safety Measurements for Heating of Instruments for Cardiovascular Interventions in Magnetic Particle Imaging (MPI) - First Experiences [J].
Duschka, Robert L. ;
Wojtczyk, Hanne ;
Panagiotopoulos, Nikolaos ;
Haegele, Julian ;
Bringout, Gael ;
Buzug, Thorsten M. ;
Barkhausen, Joerg ;
Vogt, Florian M. .
JOURNAL OF HEALTHCARE ENGINEERING, 2014, 5 (01) :79-93
[8]   How the size distribution of magnetic nanoparticles determines their magnetic particle imaging performance [J].
Eberbeck, D. ;
Wiekhorst, F. ;
Wagner, S. ;
Trahms, L. .
APPLIED PHYSICS LETTERS, 2011, 98 (18)
[9]   Magnetic Particle Imaging With Tailored Iron Oxide Nanoparticle Tracers [J].
Ferguson, R. Matthew ;
Khandhar, Amit P. ;
Kemp, Scott J. ;
Arami, Hamed ;
Saritas, Emine U. ;
Croft, Laura R. ;
Konkle, Justin ;
Goodwill, Patrick W. ;
Halkola, Aleksi ;
Rahmer, Juergen ;
Borgert, Joern ;
Conolly, Steven M. ;
Krishnan, Kannan M. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (05) :1077-1084
[10]  
Gehrcke JP, 2010, MAGNETIC NANOPARTICLES: PARTICLE SCIENCE, IMAGING TECHNOLOGY, AND CLINICAL APPLICATIONS, P73, DOI 10.1142/9789814324687_0010