Novel MRI and CT compatible stereotactic brain biopsy system in dogs using patient-specific facemasks

被引:12
作者
James, M. D. [1 ]
Bova, F. J. [2 ]
Rajon, D. A. [2 ]
Carrera-Justiz, S. [1 ]
Clemmons, R. M. [1 ]
机构
[1] Univ Florida, Small Anim Clin Sci, Gainesville, FL 32610 USA
[2] Univ Florida, Neurosurg Dept, Gainesville, FL 32610 USA
关键词
DEVICE; ACCURACY; LESIONS;
D O I
10.1111/jsap.12705
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
OBJECTIVE : The objective of this pilot study was to describe the application and first preliminary data of a novel MRI and CT compatible patient-specific facemask for stereotactic brain biopsy of intracranial lesions in dogs. METHODS : Five client-owned dogs presenting for neurological deficits consistent with forebrain disease were included in the study. All dogs had MRI findings consistent with an intracranial lesion. Using images obtained from either MRI or CT, a virtual three-dimensional model of each dog's face was generated. The contact surface of each dog's face was selected for facemask design and a target point for biopsy was chosen using specialised software and toolkits. A patient-specific facemask with an attached biopsy port with premeasured and preselected trajectory was then fabricated by a 3D printer. The facemasks were sterilised and used intraoperatively to obtain biopsy samples. Biopsy samples were submitted for both cytological and histopathological evaluation. RESULTS : The diagnostic yield based on specific histological diagnosis was 80%. The one case in which a histological diagnosis could not be confirmed had a cytological interpretation consistent with meningioma. No major complications were observed during or immediately after brain biopsy and all dogs were discharged from the hospital within 72 hours postprocedure. CLINICAL SIGNIFICANCE : In conclusion, patient-specific facemasks appear to be a safe and effective method of brain biopsy in dogs, with minimal complications observed.
引用
收藏
页码:615 / 621
页数:7
相关论文
共 16 条
[1]   COMPLICATIONS OF CT-GUIDED STEREOTAXIC BIOPSY OF INTRAAXIAL BRAIN-LESIONS [J].
BERNSTEIN, M ;
PARRENT, AG .
JOURNAL OF NEUROSURGERY, 1994, 81 (02) :165-168
[2]   COMPARATIVE MAGNETIC RESONANCE IMAGING FINDINGS BETWEEN GLIOMAS AND PRESUMED CEREBROVASCULAR ACCIDENTS IN DOGS [J].
Cervera, Vicente ;
Mai, Wilfried ;
Vite, Charles H. ;
Johnson, Victoria ;
Dayrell-Hart, Betsy ;
Seiler, Gabriela S. .
VETERINARY RADIOLOGY & ULTRASOUND, 2011, 52 (01) :33-40
[3]   DESCRIPTION AND VALIDATION OF A MAGNETIC RESONANCE IMAGING-GUIDED STEREOTACTIC BRAIN BIOPSY DEVICE IN THE DOG [J].
Chen, Annie V. ;
Wininger, Fred A. ;
Frey, Stephen ;
Comeau, Roch M. ;
Bagley, Rodney S. ;
Tucker, Russell L. ;
Schneider, Adam R. ;
Gay, John M. .
VETERINARY RADIOLOGY & ULTRASOUND, 2012, 53 (02) :150-156
[4]   Utility of magnetic resonance imaging for distinguishing neoplastic from non-neoplastic brain lesions in dogs and cats [J].
Cherubini, GB ;
Mantis, P ;
Martinez, TA ;
Lamb, CR ;
Cappello, R .
VETERINARY RADIOLOGY & ULTRASOUND, 2005, 46 (05) :384-387
[5]  
Flegel T, 2002, AM J NEURORADIOL, V23, P1160
[6]   CT-guided brain biopsy using a modified Pelorus Mark III Stereotactic System: Experience with 50 dogs [J].
Koblik, PD ;
LeCouteur, RA ;
Higgins, RJ ;
Bollen, AW ;
Vernau, KM ;
Kortz, GD ;
Ilkiw, JE .
VETERINARY RADIOLOGY & ULTRASOUND, 1999, 40 (05) :434-440
[7]   CT and MRI in veterinary patients: an update on recent advances [J].
Labruyere, Julien ;
Schwarz, Tobias .
IN PRACTICE, 2013, 35 (10) :546-563
[8]   Accuracy testing of a new stereotactic CT-guided brain biopsy device in the dog [J].
Moissonnier, P ;
Bordeau, W ;
Delisle, F ;
Devauchelle, P .
RESEARCH IN VETERINARY SCIENCE, 2000, 68 (03) :243-247
[9]   Frame-based stereotaxy in a frameless era: current capabilities, relative role, and the positive- and negative predictive values of blood through the needle [J].
Owen, Christopher M. ;
Linskey, Mark E. .
JOURNAL OF NEURO-ONCOLOGY, 2009, 93 (01) :139-149
[10]   An investigation of the potential of rapid prototyping technology for image-guided surgery [J].
Rajon, Didier A. ;
Bova, Frank J. ;
Bhasin, R. Rick ;
Friedman, William A. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2006, 7 (04) :81-98