Validation of the Beurer BM 44 upper arm blood pressure monitor for home measurement, according to the European Society of Hypertension International Protocol 2002

被引:2
|
作者
Lueders, Stephan [1 ,2 ]
Krueger, Ralf [2 ,3 ]
Zemmrich, Claudia [3 ]
Forstner, Klaus [4 ]
Sturm, Claus-Dieter [2 ]
Bramlage, Peter [2 ,3 ]
机构
[1] St Josefs Hosp, Med Clin, D-49661 Cloppenburg, Germany
[2] TEMPESTAS Inst Med Res, Cloppenburg, Germany
[3] Inst Pharmacol & Prevent Med GmbH, Potsdam, Germany
[4] Forschungsinst Klin Med Tech, Res Inst Clin Engn, Asperg, Germany
关键词
automated upper arm blood pressure; Beurer BM 44; European Society of Hypertension International Protocol 2002; validation; OFFICE;
D O I
10.1097/MBP.0b013e32835b9e8e
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective The present study aimed to validate the automated upper arm blood pressure (BP) measuring device BM 44 for home BP monitoring according to the 2002 Protocol of the European Society of Hypertension. The most important new feature of the new device was an integrated 'WHO indicator', which categorizes the patient's individual result within the WHO recommendations for target BP by a coloured scale. Methods Systolic and diastolic BPs were measured sequentially in 35 adult participants (16 men, 19 women) using a standard mercury y-tubed reference sphygmomanometer (two observers) and the BM 44 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 15 participants in phase 1 and a further 18 participants in phase 2 of the validation study. Results The BM 44 device passed phase 1 of the validation study successfully with a number of absolute differences between device and observers of 5, 10 and 15mmHg for at least 28 out of 25, 35 out of 35 and 40 out of 40 measurements, respectively. The device also achieved the targets for phases 2.1 and 2.2, with 23 and 26 participants having had at least two of three device-observers differences within 5mmHg for systolic and diastolic BP, respectively. Conclusion The Beurer BM 44 upper arm BP monitor has passed the International Protocol requirements, and hence can be recommended for home use in adults. Blood Press Monit 17:248-252 (C) 2012 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins. Blood Pressure Monitoring 2012, 17:248-252
引用
收藏
页码:248 / 252
页数:5
相关论文
共 50 条
  • [21] Validation of the Kingyield BP210 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension-International Protocol
    Zeng, Wei-Fang
    Huang, Qi-Fang
    Sheng, Chang-Sheng
    Li, Yan
    Wang, Ji-Guang
    BLOOD PRESSURE MONITORING, 2012, 17 (01) : 42 - 44
  • [22] Validation of the Health & Life HL868BA blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol
    Chen, Han-E
    Cui, Yan
    Sheng, Chang-Sheng
    Li, Li-Hua
    Li, Yan
    Wang, Ji-Guang
    BLOOD PRESSURE MONITORING, 2008, 13 (05) : 305 - 308
  • [23] Validation of the HL868ED upper-arm blood pressure monitor for clinical use and self-measurement according to the European Society of Hypertension International Protocol revision 2010
    Zhang Wei
    Lei Lei
    Li Yan
    Wang Ji-Guang
    BLOOD PRESSURE MONITORING, 2020, 25 (01) : 53 - 57
  • [24] Validation of the YuWell YE690A upper-arm blood pressure monitor, for clinic use and self-measurement, according to the European Society of Hypertension International Protocol revision 2010
    Chen, Qi
    Lei, Lei
    Li, Yan
    Wang, Ji-Guang
    BLOOD PRESSURE MONITORING, 2017, 22 (05) : 295 - 297
  • [25] Validation of the iHealth BP3 upper-arm blood pressure monitor, for clinic use and self-measurement, according to the European Society of Hypertension International Protocol revision 2010
    Chen, Can
    Shang, Fujun
    Wang, Jiepin
    Chen, Jianghong
    Ji, Na
    Wan, Yi
    BLOOD PRESSURE MONITORING, 2012, 17 (06) : 253 - 256
  • [26] Validation of the Andon KD-5917 automatic upper arm blood pressure monitor, for clinic use and self-measurement, according to the European Society of Hypertension International Protocol revision 2010
    Guo, Wan-Gang
    Li, Bing-Ling
    He, Yong
    Xue, Yu-Sheng
    Wang, Hai-Yan
    Zheng, Qiang-Sun
    Xiang, Ding-Cheng
    BLOOD PRESSURE MONITORING, 2014, 19 (04) : 242 - 245
  • [27] Validation of the custo screen pediatric blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010
    Beime, Beate
    Deutsch, Cornelia
    Krueger, Ralf
    Wolf, Andreas
    Mueller, Peter
    Hammel, Gertrud
    Bramlage, Peter
    EUROPEAN JOURNAL OF PEDIATRICS, 2017, 176 (05) : 573 - 580
  • [28] Validation of the Artsana CSI 610 automated blood pressure monitor in adults according to the international protocol of the european society of hypertension
    Pini, C.
    Pastori, M.
    Baccheschi, J.
    Gerosa, P.
    Omboni, S.
    Parati, G.
    JOURNAL OF HYPERTENSION, 2007, 25 : S39 - S39
  • [29] Validation of the Artsana CS 410 automated blood pressure monitor in adults according to the international protocol of the european society of hypertension
    Pini, C.
    Pastori, M.
    Natalizi, A.
    Gerosa, P.
    Omboni, S.
    Parati, G.
    JOURNAL OF HYPERTENSION, 2007, 25 : S39 - S39
  • [30] Validation of the custo screen pediatric blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010
    Beate Beime
    Cornelia Deutsch
    Ralf Krüger
    Andreas Wolf
    Peter Müller
    Gertrud Hammel
    Peter Bramlage
    European Journal of Pediatrics, 2017, 176 : 573 - 580