A label-free immunosensor for sensitive detection of RACK 1 cancer biomarker based on conjugated polymer modified ITO electrode

被引:5
|
作者
Aydin, Elif Burcu [1 ]
Aydin, Muhammet [1 ]
Sezginturk, Mustafa Kemal [2 ]
机构
[1] Tekirdag Namik Kemal Univ, Sci & Technol Res Ctr, Tekirdag, Turkey
[2] Canakkale Onsekiz Mart Univ, Fac Engn, Bioengn Dept, Canakkale, Turkey
关键词
Receptor for activated C kinase 1; Electrochemical biosensor; Electrochemical impedance spectroscopy; Cancer biomarker; Conjugated polymer; ELECTROCHEMICAL IMMUNOSENSOR; APTASENSOR; BIOSENSOR; SALIVA; ALPHA; SERUM;
D O I
10.1016/j.jpba.2020.113517
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new flexible biosensor based on conjugated polymer functionalized indium tin oxide (ITO) sheet was fabricated for Receptor for Activated C Kinase 1 (RACK 1) determination. Poly(3-thiophene acetic acid) (P(Thi-Ac)) was used as an immobilization matrix for construction of RACK 1 immunosensor. This polymer had a great number of carboxyl groups on its end site and these carboxyl ends provided anchoring points to the anti-RACK 1 antibodies. Anti-RACK 1 antibodies were covalently attached on the ITO electrode and recognized the RACK 1 antigens. Electrochemical characterizations were made by employing electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) techniques. Additionally, single frequency impedance method (SFI) was applied to follow the specific biointeraction between antibody and antigen. As a result of specific biointeraction, the designed immunosensor exhibited a wide linear detection range between 0.01 pg/mL and 2 pg/mL RACK 1 with a detection limit of 3.1 fg/mL. Scanning electron microscopy and atomic force microscopy analyses were employed for electrode surface morphology investigation. The designed RACK 1 biosensor had good repeatability (5.73 %, RSD), excellent reproducibility (2.5 %, RSD), long storage-stability and reusable property. In addition, the fabricated RACK 1 biosensor was applied to determine RACK 1 concentration in human serums and the recovery was ranging from 98.79%-100.22%. This work illustrated a new tool to construct a sensitive and low-cost disposable biosensor for applications in clinical monitoring. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] A sensitive label-free electrochemical immunosensor for detection of cytokeratin 19 fragment antigen 21-1 based on 3D graphene with gold nanopaticle modified electrode
    Zeng, Yan
    Bao, Jing
    Zhao, Yanan
    Huo, Danqun
    Chen, Mei
    Yang, Mei
    Fa, Huanbao
    Hou, Changjun
    TALANTA, 2018, 178 : 122 - 128
  • [42] A graphene-based label-free voltammetric immunosensor for sensitive detection of the egg allergen ovalbumin
    Eissa, Shimaa
    L'Hocine, Lamia
    Siaj, Mohamed
    Zourob, Mohammed
    ANALYST, 2013, 138 (15) : 4378 - 4384
  • [43] A sensitive label-free immunosensor for detection α-Fetoprotein in whole blood based on anticoagulating magnetic nanoparticles
    Xu, Tingting
    Chi, Bo
    Wu, Fan
    Ma, Shangshang
    Zhan, Shuyue
    Yi, Meihui
    Xu, Hong
    Mao, Chun
    BIOSENSORS & BIOELECTRONICS, 2017, 95 : 87 - 93
  • [44] Label-free MIP-SERS biosensor for sensitive detection of colorectal cancer biomarker
    Lu, Yulin
    Liu, Qunshan
    Fu, Bangguo
    Li, Pan
    Xu, Weiping
    TALANTA, 2023, 258
  • [45] A sensitive and selective approach for detection of IL 1α cancer biomarker using disposable ITO electrode modified with epoxy-substituted polythiophene polymer
    Aydin, Muhammet
    BIOSENSORS & BIOELECTRONICS, 2019, 144
  • [46] A sensitive electrochemical immunosensor for label-free detection of Zika-virus protein
    Ajeet Kaushik
    Adriana Yndart
    Sanjeev Kumar
    Rahul Dev Jayant
    Arti Vashist
    Ashley N. Brown
    Chen-Zhong Li
    Madhavan Nair
    Scientific Reports, 8
  • [47] A sensitive electrochemical immunosensor for label-free detection of Zika-virus protein
    Kaushik, Ajeet
    Yndart, Adriana
    Kumar, Sanjeev
    Jayant, Rahul Dev
    Vashist, Arti
    Brown, Ashley N.
    Li, Chen-Zhong
    Nair, Madhavan
    SCIENTIFIC REPORTS, 2018, 8
  • [48] A label-free electrochemical immunosensor for direct, signal-on and sensitive pesticide detection
    Tran, H. V.
    Yougnia, R.
    Reisberg, S.
    Piro, B.
    Serradji, N.
    Nguyen, T. D.
    Tran, L. D.
    Dong, C. Z.
    Pham, M. C.
    BIOSENSORS & BIOELECTRONICS, 2012, 31 (01): : 62 - 68
  • [49] Microconductometric immunosensor for label-free and sensitive detection of Gram-negative bacteria
    El Ichi, Sarra
    Leon, Fanny
    Vossier, Ludivine
    Marchandin, Helene
    Errachid, Abdelhamid
    Coste, Joliette
    Jaffrezic-Renault, Nicole
    Fournier-Wirth, Chantal
    BIOSENSORS & BIOELECTRONICS, 2014, 54 : 378 - 384
  • [50] Label-Free, Highly Sensitive Electrochemical Aptasensors Using Polymer-Modified Reduced Graphene Oxide for Cardiac Biomarker Detection
    Sharma, Abhinav
    Bhardwa, Jyoti
    Jang, Jaesung
    ACS OMEGA, 2020, 5 (08): : 3924 - 3931