A label-free immunosensor for sensitive detection of RACK 1 cancer biomarker based on conjugated polymer modified ITO electrode

被引:5
|
作者
Aydin, Elif Burcu [1 ]
Aydin, Muhammet [1 ]
Sezginturk, Mustafa Kemal [2 ]
机构
[1] Tekirdag Namik Kemal Univ, Sci & Technol Res Ctr, Tekirdag, Turkey
[2] Canakkale Onsekiz Mart Univ, Fac Engn, Bioengn Dept, Canakkale, Turkey
关键词
Receptor for activated C kinase 1; Electrochemical biosensor; Electrochemical impedance spectroscopy; Cancer biomarker; Conjugated polymer; ELECTROCHEMICAL IMMUNOSENSOR; APTASENSOR; BIOSENSOR; SALIVA; ALPHA; SERUM;
D O I
10.1016/j.jpba.2020.113517
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new flexible biosensor based on conjugated polymer functionalized indium tin oxide (ITO) sheet was fabricated for Receptor for Activated C Kinase 1 (RACK 1) determination. Poly(3-thiophene acetic acid) (P(Thi-Ac)) was used as an immobilization matrix for construction of RACK 1 immunosensor. This polymer had a great number of carboxyl groups on its end site and these carboxyl ends provided anchoring points to the anti-RACK 1 antibodies. Anti-RACK 1 antibodies were covalently attached on the ITO electrode and recognized the RACK 1 antigens. Electrochemical characterizations were made by employing electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) techniques. Additionally, single frequency impedance method (SFI) was applied to follow the specific biointeraction between antibody and antigen. As a result of specific biointeraction, the designed immunosensor exhibited a wide linear detection range between 0.01 pg/mL and 2 pg/mL RACK 1 with a detection limit of 3.1 fg/mL. Scanning electron microscopy and atomic force microscopy analyses were employed for electrode surface morphology investigation. The designed RACK 1 biosensor had good repeatability (5.73 %, RSD), excellent reproducibility (2.5 %, RSD), long storage-stability and reusable property. In addition, the fabricated RACK 1 biosensor was applied to determine RACK 1 concentration in human serums and the recovery was ranging from 98.79%-100.22%. This work illustrated a new tool to construct a sensitive and low-cost disposable biosensor for applications in clinical monitoring. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Label-free ITO-based immunosensor for the detection of very low concentrations of pathogenic bacteria
    Barreiros dos Santos, M.
    Azevedo, S.
    Agusil, J. P.
    Prieto-Simon, B.
    Sporer, C.
    Torrents, E.
    Juarez, A.
    Teixeira, V.
    Samitier, J.
    BIOELECTROCHEMISTRY, 2015, 101 : 146 - 152
  • [22] Sensitive immunosensor for the label-free determination of tumor marker based on carbon nanotubes/mesoporous silica and graphene modified electrode
    Lin, Jiehua
    Wei, Zhijing
    Zhang, Huihui
    Shao, Meijia
    BIOSENSORS & BIOELECTRONICS, 2013, 41 : 342 - 347
  • [23] Development of a Label-Free Immunosensor for Clusterin Detection as an Alzheimer's Biomarker
    Islam, Kamrul
    Damiati, Samar
    Sethi, Jagriti
    Suhail, Ahmed
    Pan, Genhua
    SENSORS, 2018, 18 (01)
  • [24] A Label-Free Immunosensor Based on Gold Nanoparticles/Thionine for Sensitive Detection of PAT Protein in Genetically Modified Crops
    Yang, Qianwen
    Wang, Yu
    Liu, Xiaofeng
    Liu, Hua
    Bao, Huifang
    Wang, Jinbin
    Zeng, Haijuan
    FRONTIERS IN CHEMISTRY, 2021, 9
  • [25] Electrochemical immunosensor with N-doped graphene-modified electrode for label-free detection of the breast cancer biomarker CA 15-3
    Li, He
    He, Jing
    Li, Songjun
    Turner, Anthony P. F.
    BIOSENSORS & BIOELECTRONICS, 2013, 43 : 25 - 29
  • [26] Sensitive and selective label-free DNA detection by conjugated polymer-based microarrays and intercalating dye
    Lee, Kangwon
    Maisel, Katharina
    Rouillard, Jean-Marie
    Gulari, Erdogan
    Kim, Jinsang
    CHEMISTRY OF MATERIALS, 2008, 20 (09) : 2848 - 2850
  • [27] Label-free Electrochemical Immunosensor for Sensitive Detection of Rheumatoid Arthritis Biomarker Anti-CCP-ab
    Ma, Jing
    Li, Dai
    Sun, Bolu
    Hou, Xiaohui
    Zhang-Peng, Xinru
    Li, Wen
    Zhang, Yan
    Hu, Fangdi
    Shi, Xiaofeng
    ELECTROANALYSIS, 2022, 34 (04) : 761 - 771
  • [28] A label-free electrochemical immunosensor for the detection of cancer biomarker α-fetoprotein (AFP) based on hydroxyapatite induced redox current
    Sun, Jisan
    Tian, Dazhi
    Guo, Qingjun
    Zhang, Li
    Jiang, Wentao
    Yang, Minghui
    ANALYTICAL METHODS, 2016, 8 (40) : 7319 - 7323
  • [29] Label-free electrochemical immunosensor for picomolar detection of the cervical cancer biomarker MCM5
    Barhoum, Ahmed
    Forster, Robert J.
    ANALYTICA CHIMICA ACTA, 2022, 1225
  • [30] A label-free electrochemical impedance immunosensor for the sensitive detection of aflatoxin B1
    Chen, Liguo
    Jiang, Jianhui
    Shen, Guoli
    Yu, Ruqin
    ANALYTICAL METHODS, 2015, 7 (06) : 2354 - 2359