A label-free immunosensor for sensitive detection of RACK 1 cancer biomarker based on conjugated polymer modified ITO electrode

被引:5
|
作者
Aydin, Elif Burcu [1 ]
Aydin, Muhammet [1 ]
Sezginturk, Mustafa Kemal [2 ]
机构
[1] Tekirdag Namik Kemal Univ, Sci & Technol Res Ctr, Tekirdag, Turkey
[2] Canakkale Onsekiz Mart Univ, Fac Engn, Bioengn Dept, Canakkale, Turkey
关键词
Receptor for activated C kinase 1; Electrochemical biosensor; Electrochemical impedance spectroscopy; Cancer biomarker; Conjugated polymer; ELECTROCHEMICAL IMMUNOSENSOR; APTASENSOR; BIOSENSOR; SALIVA; ALPHA; SERUM;
D O I
10.1016/j.jpba.2020.113517
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new flexible biosensor based on conjugated polymer functionalized indium tin oxide (ITO) sheet was fabricated for Receptor for Activated C Kinase 1 (RACK 1) determination. Poly(3-thiophene acetic acid) (P(Thi-Ac)) was used as an immobilization matrix for construction of RACK 1 immunosensor. This polymer had a great number of carboxyl groups on its end site and these carboxyl ends provided anchoring points to the anti-RACK 1 antibodies. Anti-RACK 1 antibodies were covalently attached on the ITO electrode and recognized the RACK 1 antigens. Electrochemical characterizations were made by employing electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) techniques. Additionally, single frequency impedance method (SFI) was applied to follow the specific biointeraction between antibody and antigen. As a result of specific biointeraction, the designed immunosensor exhibited a wide linear detection range between 0.01 pg/mL and 2 pg/mL RACK 1 with a detection limit of 3.1 fg/mL. Scanning electron microscopy and atomic force microscopy analyses were employed for electrode surface morphology investigation. The designed RACK 1 biosensor had good repeatability (5.73 %, RSD), excellent reproducibility (2.5 %, RSD), long storage-stability and reusable property. In addition, the fabricated RACK 1 biosensor was applied to determine RACK 1 concentration in human serums and the recovery was ranging from 98.79%-100.22%. This work illustrated a new tool to construct a sensitive and low-cost disposable biosensor for applications in clinical monitoring. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Label-free electrochemical immunosensor for sensitive detection of pesticide residue in vegetables
    Han, En
    Zhou, Li-Na
    Yan, Jing-Kun
    Cai, Jian-Rong
    Tian, Qing-Rong
    Zeng, Ni
    Modern Food Science and Technology, 2014, 30 (10) : 268 - 273
  • [22] Ultrasensitive determination of cadherin-like protein 22 with a label-free electrochemical immunosensor using brush type poly(thiophene-g-glycidylmethacrylate) modified disposable ITO electrode
    Aydin, Elif Burcu
    Aydin, Muhammet
    Sezginturk, Mustafa Kemal
    TALANTA, 2019, 200 : 387 - 397
  • [23] Earlier Detection of Alzheimer's Disease Based on a Novel Biomarker cis P-tau by a Label-Free Electrochemical Immunosensor
    Shiravandi, Ayoub
    Yari, Farzaneh
    Tofigh, Nahid
    Ashtiani, Mohammad Kazemi
    Shahpasand, Koorosh
    Ghanian, Mohammad-Hossein
    Shekari, Faezeh
    Faridbod, Farnoush
    BIOSENSORS-BASEL, 2022, 12 (10):
  • [24] Boron nitride nanosheet modified label-free electrochemical immunosensor for cancer antigen 125 detection
    Ondes, Baha
    Evli, Sinem
    Uygun, Murat
    Uygun, Deniz Aktas
    BIOSENSORS & BIOELECTRONICS, 2021, 191
  • [25] Label-free and label-based electrochemical detection of disease biomarker proteins
    Lestari, Tias Febriana Hanifa
    Irkham, Irkham
    Pratomo, Uji
    Gaffar, Shabarni
    Zakiyyah, Salma Nur
    Rahmawati, Isnaini
    Topkaya, Seda Nur
    Hartati, Yeni Wahyuni
    ADMET AND DMPK, 2024, 12 (03): : 463 - 486
  • [26] A graphene-based label-free voltammetric immunosensor for sensitive detection of the egg allergen ovalbumin
    Eissa, Shimaa
    L'Hocine, Lamia
    Siaj, Mohamed
    Zourob, Mohammed
    ANALYST, 2013, 138 (15) : 4378 - 4384
  • [27] A sensitive label-free immunosensor for detection α-Fetoprotein in whole blood based on anticoagulating magnetic nanoparticles
    Xu, Tingting
    Chi, Bo
    Wu, Fan
    Ma, Shangshang
    Zhan, Shuyue
    Yi, Meihui
    Xu, Hong
    Mao, Chun
    BIOSENSORS & BIOELECTRONICS, 2017, 95 : 87 - 93
  • [28] Label-free paper-based electrochemical impedance immunosensor for human interferon gamma detection
    Ruecha, Nipapan
    Shin, Kwanwoo
    Chailapakul, Orawon
    Rodthongkum, Nadnudda
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 279 : 298 - 304
  • [29] A high sensitive label-free immunosensor for the determination of human serum IgG using overoxidized polypyrrole decorated with gold nanoparticle modified electrode
    Tabrizi, Mahmoud Amouzadeh
    Shamsipur, Mojtaba
    Mostafaie, Ali
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 59 : 965 - 969
  • [30] Impedimetric immunosensor based on SWCNT-COOH modified gold microelectrodes for label-free detection of deep venous thrombosis biomarker
    Bourigua, S.
    Hnaien, M.
    Bessueille, F.
    Lagarde, F.
    Dzyadevych, S.
    Maaref, A.
    Bausells, J.
    Errachid, A.
    Renault, N. Jaffrezic
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (04) : 1278 - 1282