Indirect Square-Wave Voltammetric Determination of Cefepime in the Presence of Formaldehyde

被引:0
|
作者
Suslu, Incilay [1 ]
Celebier, Mustafa [1 ]
Kablan, Sevilay E. [1 ]
Altinoz, Sacide [1 ]
机构
[1] Hacettepe Univ, Dept Analyt Chem, Fac Pharm, TR-06100 Ankara, Turkey
来源
LATIN AMERICAN JOURNAL OF PHARMACY | 2016年 / 35卷 / 10期
关键词
cefepime; optimization; pharmaceutical formulations; Schiff base; square-wave voltammetry; validation; LIQUID-CHROMATOGRAPHIC DETERMINATION; HUMAN PLASMA; ELECTROCHEMICAL DETERMINATION; PHARMACEUTICAL ANALYSIS; MODIFIED ELECTRODES; MERCURY-ELECTRODE; METHOD VALIDATION; GENERATION; REDUCTION; EFFICACY;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
In this study, a new, easy, and sensitive voltammetric approach was proposed for indirect determination of cefepime by forming Schiff base in its pharmaceutical formulations. A square-wave voltammetric method on a hanging mercury drop electrode was developed for the indirect determination of cefepime. The effects of supporting electrolyte, pH, concentration of formaldehyde, and instrumental parameters on the voltammetric response of cefepime were studied to select the optimum experimental conditions. In the presence of 0.118 M formaldehyde, cefepime exhibited a sensitive, highly reproducible, and well-defined cathodic peak using Britton-Robinson buffer at pH 8.0. The optimum conditions were described as 70 Hz frequency, 6 mV scan increment and 30 mV pulse amplitude. The validation parameters such as linearity, sensitivity, repeatability, accuracy, precision, selectivity, recovery, robustness and ruggedness were tested according to the ICH guideline. The monitored peak current was directly proportional to the concentration of cefepime and it shows a linear response in the range from 0.70 to 5.26 mu g/mL (r = 0.9995). Limit of detection (LOD) and limit of quantification (LOQ) were found 0.19 and 0.70 mu g/mL, respectively. After validation of the developed method, it was applied on the analysis of pharmaceutical formulations. Mean recovery of 100.02 +/- 0.54 (n = 7) was achieved for assay of cefepime in Maxipime (R) injection.
引用
收藏
页码:2246 / 2253
页数:8
相关论文
共 50 条
  • [21] Simultaneous square-wave voltammetric determination of acetazolamide and theophylline in pharmaceutical formulations
    İclal Bulut
    Russian Journal of Electrochemistry, 2016, 52 : 427 - 434
  • [22] Voltammetric behavior of sulfadimetoxol using square-wave and adsorptive stripping square-wave techniques
    Berzas, JJ
    Rodriguez, J
    Lemus, JM
    Castaneda, G
    ELECTROANALYSIS, 1997, 9 (06) : 474 - 477
  • [23] Simultaneous square-wave voltammetric determination of acetazolamide and theophylline in pharmaceutical formulations
    Bulut, Iclal
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2016, 52 (05) : 427 - 434
  • [24] Electrochemical studies and square-wave voltammetric determination of fenofibrate in pharmaceutical formulations
    Yardimci, C
    Özaltin, N
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (02) : 495 - 498
  • [25] SQUARE-WAVE AND SQUARE-WAVE ADSORPTIVE STRIPPING VOLTAMMETRIC COMPARISON OF THE ANTIINFLAMMATORY DRUGS PIROXICAM AND TENOXICAM
    ELMAALI, NA
    VIRE, JC
    PATRIARCHE, GJ
    GHANDOUR, MA
    CHRISTIAN, GD
    ANALYTICAL SCIENCES, 1990, 6 (02) : 245 - 250
  • [26] Voltammetric behavior of pyrimethamine in veterinary formulations using square-wave and adsorptive square-wave techniques
    Berzas, JJ
    Rodriguez, J
    Lemus, JM
    Castaneda, G
    ELECTROANALYSIS, 1995, 7 (12) : 1156 - 1160
  • [27] Square-wave voltammetric examination of the Jordan River
    Thurman, Chris
    Iles, Peter
    Giddings, Lu
    Valcarce, Ron
    Bastian, Neil
    Alvarez, Mary
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 247
  • [28] Voltammetric determination of Imatinib (Gleevec) and its main metabolite using square-wave and adsorptive stripping square-wave techniques in urine samples
    Rodríguez, J
    Berzas, JJ
    Castañeda, G
    Rodríguez, N
    TALANTA, 2005, 66 (01) : 202 - 209
  • [29] Electrooxidation of Some Antifungal Agents and Their Square-Wave Voltammetric Determination in Cosmetics and Pharmaceutics
    Mielech-Lukasiewicz, Katarzyna
    Puzanowska-Tarasiewicz, Helena
    Niedzielko, Anna
    ANALYTICAL LETTERS, 2011, 44 (06) : 955 - 967
  • [30] A Square-Wave Adsorptive Stripping Voltammetric Method for Determination of Fast Green Dye
    Al-Ghamdi, Ali F.
    JOURNAL OF AOAC INTERNATIONAL, 2009, 92 (06) : 1714 - 1719