Electrochemical Performance of Micropillar Array Electrodes in Microflows

被引:16
|
作者
Liu, Bo [1 ]
Lv, Chuanwen [1 ]
Chen, Chaozhan [1 ]
Ran, Bin [1 ]
Lan, Minbo [2 ]
Chen, Huaying [1 ]
Zhu, Yonggang [1 ]
机构
[1] Harbin Inst Technol Shenzhen, Ctr Microflows & Nanoflows, Shenzhen 518000, Peoples R China
[2] East China Univ Sci & Technol, Shanghai Key Lab Funct Mat Chem, Sch Chem & Mol Engn, Shanghai 200237, Peoples R China
基金
中国国家自然科学基金;
关键词
microchip-based electrochemical detection system; micropillars array electrode; numerical simulation; tail effect; CHANNEL MICROBAND ELECTRODES; DISK MICROELECTRODE; IN-SITU; SIMULATION; VOLTAMMETRY; TRANSPORT; FABRICATION; ASSEMBLIES; MICROCHIP; REGIMES;
D O I
10.3390/mi11090858
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The microchip-based electrochemical detection system (mu EDS) has attracted plenty of research attention due to its merits including the capability in high-density integration, high sensitivity, fast analysis time, and reduced reagent consumption. The miniaturized working electrode is usually regarded as the core component of the mu EDS, since its characteristic directly determines the performance of the whole system. Compared with the microelectrodes with conventional shapes such as the band, ring and disk, the three-dimensional (3D) micropillar array electrode (mu AE) has demonstrated significant potential in improving the current response and decreasing the limits of detection due to its much larger reaction area. In this study, the numerical simulation method was used to investigate the performance of the mu EDS, and both the geometrical and hydrodynamic parameters, including the micropillars shape, height, arrangement form and the flow rate of the reactant solution, were taken into consideration. The tail effect in mu AEs was also quantitatively analyzed based on a pre-defined parameter of the current density ratio. In addition, a PDMS-based 3D mu AE was fabricated and integrated into the microchannel for the electrochemical detection. The experiments of cyclic voltammetry (CV) and chronoamperometry (CA) were conducted, and a good agreement was found between the experimental and simulation results. This study would be instructive for the configuration and parameters design of the mu EDS, and the presented method can be adopted to analyze and optimize the performance of nanochip-based electrochemical detection system (nEDS).
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Micromachining of predesigned perpendicular copper micropillar array by scanning electrochemical microscopy
    Han, Lianhuan
    Ma, Zhen
    Wang, Chao
    Ye, Zuoyan
    Su, Jian-Jia
    Luo, ShiYi
    Wu, Yuan-Fei
    Zhan, Dongping
    ELECTROCHIMICA ACTA, 2023, 442
  • [2] Simulation of dewetting process on micropillar array
    Chau, S. W.
    Lin, C. H.
    Guan, J.
    Lee, L. J.
    PROCEEDINGS OF THE SEVENTH INTERNATIONAL CONFERENCE ON FLUID POWER TRANSMISSION AND CONTROL, 2009, : 936 - 939
  • [3] Electrochemical Redox Cycling Behavior of Gold Nanoring Electrodes Microfabricated on a Silicon Micropillar
    Yin, Haocheng
    Tan, Chao
    Siddiqui, Shabnam
    Arumugam, Prabhu U.
    MICROMACHINES, 2023, 14 (04)
  • [4] Electrochemical Signature of Escherichia coli on Nickel Micropillar Array Electrode for Early Biofilm Characterization
    Astorga, Solange E.
    Hu, Liang Xing
    Marsili, Enrico
    Huang, Yizhong
    CHEMELECTROCHEM, 2019, 6 (17): : 4674 - 4680
  • [5] Development of inlaid electrodes for whole column electrochemical detection in HPLC
    Seo, Jung-Ho
    Leow, Pei Ling
    Cho, Si-Hyeong
    Lim, Hyun-Woo
    Kim, Jin-Young
    Patel, Bhavik Anil
    Park, Jin-Goo
    O'Hare, Danny
    LAB ON A CHIP, 2009, 9 (15) : 2238 - 2244
  • [6] Development of Electrohydrodynamic Micropumps with Micropillar Electrodes
    Kazemi, P. Zangeneh
    Selvaganapathy, P. Ravi
    Ching, Chan Y.
    MNHMT2009, VOL 1, 2010, : 65 - 72
  • [7] Multiplexed detection of biomarkers using a microfluidic chip integrated with mass-producible micropillar array electrodes
    Chen, Chaozhan
    Ran, Bin
    Liu, Bo
    Liu, Xiaoxuan
    Zhang, Ziteng
    Li, Yan
    Li, Hongchun
    Lan, Minbo
    Zhu, Yonggang
    ANALYTICA CHIMICA ACTA, 2023, 1272
  • [8] Performance Analysis of Optimized Screen-Printed Electrodes for Electrochemical Sensing
    Roslan, Nurul Amira Farhana
    Ab Rahim, Rosminazuin
    Ralib, Aliza Aini Md
    Za'bah, Nor Farahidah
    Nordin, Anis Nurashikin
    Bashri, Mohd Saiful Riza
    Suhaimi, Muhammad Irsyad
    Samsudin, Zambri
    Ming, Lim Lai
    Sugandi, Gandi
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2022, 14 (03): : 250 - 261
  • [9] Micropillar array columns for advancing nanoflow HPLC
    Rozing, Gerard
    MICROCHEMICAL JOURNAL, 2021, 170
  • [10] Assessment of pillar-array electrodes for electrochemical flow reactors using a novel hydrodynamic electrode performance factor
    De Rop, Michiel
    Arenas, Luis F.
    De Wolf, Renee
    Hereijgers, Jonas
    CHEMICAL ENGINEERING JOURNAL, 2024, 500