e-calibrations:: using the Internet to deliver calibration services in real time at lower cost

被引:6
作者
Desrosiers, M
Nagy, V
Puhl, J
Glenn, R
Densock, R
Stieren, D
Lang, B
Kamlowski, A
Maier, D
Heiss, A
机构
[1] NIST, Ionizing Radiat Div, Phys Lab, Gaithersburg, MD 20899 USA
[2] NIST, Informat Technol Lab, Gaithersburg, MD 20899 USA
[3] NIST, Mfg Engn Lab, Gaithersburg, MD 20899 USA
[4] Miami Univ, Dept Phys, Oxford, OH 45056 USA
[5] Bruker Analyt GMBH, EPR Div, D-76827 Rheinstetten Karlsruhe, Germany
[6] Bruker Instruments Inc, EPR Div, Billerica, MA 01821 USA
基金
美国国家科学基金会;
关键词
alanine; calibrations; dosimetry; electron paramagnetic resonance; Internet; remote control;
D O I
10.1016/S0969-806X(01)00609-0
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The National Institute of Standards and Technology (NIST) is expanding into a new frontier in the delivery of measurement services. The Internet will be employed to provide industry with electronic traceability to national standards. This is a radical departure from the traditional modes of traceability and presents many new challenges. The traditional mail-based calibration service relies on sending artifacts to the user, who then mails them back to NIST for evaluation. The new service will deliver calibration results to the industry customer on-demand, in real-time, at a lower cost. The calibration results can be incorporated rapidly into the production process to ensure the highest quality manufacturing. The service would provide the US radiation processing industry with a direct link to the NIST calibration facilities and its expertise, and provide an interactive feedback process between industrial processing and the national measurement standard. Moreover, an Internet calibration system should contribute to the removal of measurement-related trade barriers. Published by Elsevier Science Ltd.
引用
收藏
页码:759 / 763
页数:5
相关论文
共 4 条
  • [1] *ASTM, 1999, ANN BOOKS ASTM STAND, P803
  • [2] Advancements in accuracy of the alanine EPR dosimetry system Part III: Usefulness of an adjacent reference sample
    Nagy, V
    Sleptchonok, OF
    Desrosiers, MF
    Weber, RT
    Heiss, AH
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2000, 59 (04) : 429 - 441
  • [3] Advancements in accuracy of the alanine dosimetry system. Part 2. The influence of the irradiation temperature
    Nagy, V
    Puhl, JM
    Desrosiers, MF
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2000, 57 (01) : 1 - 9
  • [4] Advancements in accuracy of the alanine dosimetry system. Part 1. The effects of environmental humidity
    Sleptchonok, OF
    Nagy, V
    Desrosiers, MF
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2000, 57 (02) : 115 - 133