Evaluation of image quality using 1:1 pitch and 1.5:1 pitch helical CT in children: A comparative study

被引:41
作者
Vade, A [1 ]
Demos, TC [1 ]
Olson, MC [1 ]
Subbaiah, P [1 ]
Turbin, RC [1 ]
Vickery, K [1 ]
Corrigan, K [1 ]
机构
[1] OAKLAND UNIV,DEPT MATH SCI,ROCHESTER,MI 48309
关键词
D O I
10.1007/BF03178045
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objective. The objective of this study was to compare the quality of 1 : 1 and 1.5 : 1 pitch helical contrast-enhanced thoracic and abdominal CT images in children who cannot cooperate for breath holding. Materials and methods This is a retrospective study of 33 contrast-enhanced CT examinations in 11 children of 0-4 years of age. All children had an initial CT study using 1 : 1 pitch helical scanning followed over the next 6-36 months by one to four CT examinations with 1.5 : 1 pitch. Radiation dose with the two techniques was measured with a pencil ionization chamber. Results. The two techniques provided comparable overall image quality. There was 33 % less radiation dose with 1.5 : 1 pitch helical scanning. Conclusion. The 1.5 : 1 pitch helical CT provides comparable quality images and a smaller radiation dose than 1 : 1 pitch in examining children aged 0-4 years.
引用
收藏
页码:891 / 893
页数:3
相关论文
共 10 条
[1]  
BRINK JA, 1992, RADIOLOGY, V185, P126
[2]   SPIRAL CT - DECREASED SPATIAL-RESOLUTION INVIVO DUE TO BROADENING OF SECTION-SENSITIVITY PROFILE [J].
BRINK, JA ;
HEIKEN, JP ;
BALFE, DM ;
SAGEL, SS ;
DICROCE, J ;
VANNIER, MW .
RADIOLOGY, 1992, 185 (02) :469-474
[3]   PULMONARY NODULE - EVALUATION WITH SPIRAL VOLUMETRIC CT [J].
COSTELLO, P ;
ANDERSON, W ;
BLUME, D .
RADIOLOGY, 1991, 179 (03) :875-876
[4]   SPIRAL CT OF THE PANCREAS [J].
DUPUY, DE ;
COSTELLO, P ;
ECKER, CP .
RADIOLOGY, 1992, 183 (03) :815-818
[5]   SPIRAL(HELICAL) CT [J].
HEIKEN, JP ;
BRINK, JA ;
VANNIER, MW .
RADIOLOGY, 1993, 189 (03) :647-656
[6]   SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION [J].
KALENDER, WA ;
SEISSLER, W ;
KLOTZ, E ;
VOCK, P .
RADIOLOGY, 1990, 176 (01) :181-183
[7]   EVALUATION OF SECTION SENSITIVITY PROFILES AND IMAGE NOISE IN SPIRAL CT [J].
POLACIN, A ;
KALENDER, WA ;
MARCHAL, G .
RADIOLOGY, 1992, 185 (01) :29-35
[8]   CT OF THE CHEST AND ABDOMEN IN PATIENTS ON MECHANICAL PULMONARY VENTILATORS - QUALITY OF IMAGES MADE AT 0.6-SEC VS 1.0-SEC [J].
POSNIAK, HV ;
OLSON, MC ;
DEMOS, TC ;
PIERCE, KL ;
KALBHEN, CL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (05) :1073-1077
[9]   PULMONARY NODULES - DETECTION WITH THICK-SECTION SPIRAL CT VERSUS CONVENTIONAL CT [J].
REMYJARDIN, M ;
REMY, J ;
GIRAUD, F ;
MARQUETTE, CH .
RADIOLOGY, 1993, 187 (02) :513-520
[10]   DETECTION OF FOCAL HEPATIC-LESIONS WITH SPIRAL CT - COMPARISON OF 4-MM AND 8-MM INTERSCAN SPACING [J].
URBAN, BA ;
FISHMAN, EK ;
KUHLMAN, JE ;
KAWASHIMA, A ;
HENNESSEY, JG ;
SIEGELMAN, SS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (04) :783-785