A computational framework for investigating the positional stability of aortic endografts

被引:49
作者
Prasad, Anamika [1 ]
Xiao, Nan [1 ,4 ]
Gong, Xiao-Yan [3 ]
Zarins, Christopher K. [2 ]
Figueroa, C. Alberto [4 ]
机构
[1] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Surg, Stanford, CA 94305 USA
[3] Med Implant Mech LLC, Alisoviejo, CA 92656 USA
[4] St Thomas Hosp, Dept Biomed Engn, Kings Coll London, London SE1 7EH, England
关键词
Stent-graft; Migration; Aneurysm; Friction; CSM; CFD; Fixation; STENT-GRAFT MIGRATION; ENDOVASCULAR TREATMENT; ANEURYSM REPAIR; ABDOMINAL-AORTA; NECK ANGULATION; ILIAC FIXATION; BLOOD-FLOW; BEHAVIOR; DISPLACEMENT; MODELS;
D O I
10.1007/s10237-012-0450-3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Endovascular aneurysm repair (Greenhalgh in N Engl J Med 362(20):1863-1871, 2010) techniques have revolutionized the treatment of thoracic and abdominal aortic aneurysm disease, greatly reducing the perioperative mortality and morbidity associated with open surgical repair techniques. However, EVAR is not free of important complications such as late device migration, endoleak formation and fracture of device components that may result in adverse events such as aneurysm enlargement, need for long-term imaging surveillance and secondary interventions or even death. These complications result from the device inability to withstand the hemodynamics of blood flow and to keep its originally intended post-operative position over time. Understanding the in vivo biomechanical working environment experienced by endografts is a critical factor in improving their long-term performance. To date, no study has investigated the mechanics of contact between device and aorta in a three-dimensional setting. In this work, we developed a comprehensive Computational Solid Mechanics and Computational Fluid Dynamics framework to investigate the mechanics of endograft positional stability. The main building blocks of this framework are: (1) Three-dimensional non-planar aortic and stent-graft geometrical models, (2) Realistic multi-material constitutive laws for aorta, stent, and graft, (3) Physiological values for blood flow and pressure, and (4) Frictional model to describe the contact between the endograft and the aorta. We introduce a new metric for numerical quantification of the positional stability of the endograft. Lastly, in the results section, we test the framework by investigating the impact of several factors that are clinically known to affect endograft stability.
引用
收藏
页码:869 / 887
页数:19
相关论文
共 69 条
[1]  
Ahrens J., 2005, PARAVIEW END USER TO
[2]   Anatomical risk factors for proximal perigraft endoleak and graft migration following endovascular repair of abdominal aortic aneurysms [J].
Albertini, JN ;
Kalliafas, S ;
Travis, S ;
Yusuf, SW ;
Macierewicz, JA ;
Whitaker, SC ;
Elmarasy, NM ;
Hopkinson, BR .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2000, 19 (03) :308-312
[3]   Analysis of type I endoleaks in a stented abdominal aortic aneurysm [J].
Amblard, Anne ;
Berre, Helene Walter-Le ;
Bou-Said, Benyebka ;
Brunet, Michel .
MEDICAL ENGINEERING & PHYSICS, 2009, 31 (01) :27-33
[4]  
[Anonymous], SIMULIA ABAQUS THEOR
[5]   Iliac fixation length and resistance to in-vivo stent-graft displacement [J].
Arko, FR ;
Heikkinen, M ;
Lee, ES ;
Bass, A ;
Alsac, JM ;
Zarins, CK .
JOURNAL OF VASCULAR SURGERY, 2005, 41 (04) :664-670
[6]   Guidelines for the treatment of abdominal aortic aneurysms - Report of a subcommittee of the Joint Council of the American Association for Vascular Surgery and Society for Vascular Surgery [J].
Brewster, DC ;
Cronenwett, JL ;
Hallett, JW ;
Johnston, KW ;
Krupski, WC ;
Matsumura, JS .
JOURNAL OF VASCULAR SURGERY, 2003, 37 (05) :1106-1117
[7]   An uncoupled directional damage model for fibred biological soft tissues.: Formulation and computational aspects [J].
Calvo, B. ;
Pena, E. ;
Martinez, M. A. ;
Doblare, M. .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2007, 69 (10) :2036-2057
[8]   CONTINUUM DAMAGE MECHANICS .1. GENERAL CONCEPTS [J].
CHABOCHE, JL .
JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 1988, 55 (01) :59-64
[9]   The effect of vessel material properties and pulsatile wall motion on the fixation of a proximal stent of an endovascular graft [J].
Corbett, T. J. ;
Molony, D. S. ;
Callanan, A. ;
McGloughlin, T. M. .
MEDICAL ENGINEERING & PHYSICS, 2011, 33 (01) :106-111
[10]   Long-Term Outcome of Open or Endovascular Repair of Abdominal Aortic Aneurysm [J].
De Bruin, Jorg L. ;
Baas, Annette F. ;
Buth, Jaap ;
Prinssen, Monique ;
Verhoeven, Eric L. G. ;
Cuypers, Philippe W. M. ;
van Sambeek, Marc R. H. M. ;
Balm, Ron ;
Grobbee, Diederick E. ;
Blankensteijn, Jan D. .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 362 (20) :1881-1889