Local Versus General Anesthesia in Transcatheter Aortic Valve Replacement

被引:30
作者
Jabbar, Avais [1 ]
Khurana, Ayush [1 ]
Mohammed, Ashfaq [1 ]
Das, Rajiv [1 ]
Zaman, Azfar [1 ]
Edwards, Richard [1 ]
机构
[1] Freeman Rd Hosp, Ctr Cardiothorac, Cardiothorac Serv, Newcastle Upon Tyne, Tyne & Wear, England
关键词
EDWARDS SAPIEN-XT; COREVALVE PROSTHESIS; IMPLANTATION; STENOSIS; FEASIBILITY; OUTCOMES; SAFETY;
D O I
10.1016/j.amjcard.2016.08.051
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transcatheter aortic valve replacement (TAVR) is conventionally performed under general anesthesia (GA) allowing intraoperative transoesophageal echocardiogram imaging. We present our experience in patients having the procedure under local anesthesia (LA), who were subsequently transferred to a low dependency unit postprocedure, to assess safety and length of hospital stay. We retrospectively assessed all the transfemoral TAVR procedures conducted at our center from January 03, 2011. Of 216 patients, 145 had the procedure under GA and 71 under LA. Both groups were similar with respect to age, co-morbidities, Euro Score, and the severity of the aortic stenosis. The procedure time was. significantly shorter in the LA group measured from time in room to skin closure (108 vs 143 minutes, p <0.001). Skin open to skin closure time were the same in both groups (78 vs 79.4 minutes, p = 0.57). There was no difference in 30 days: aortic regurgitation > mild (2.1% in GA and 2.8% in LA, p = 0.67), need for permanent pacing (3.4% in GA and 1.4% in LA, p = 0.32), and disabling cerebrovascular accidents (1.4% and 1.4%, p = 1.0). The 30-day survival was not significantly different (95.9% in GA and 100% in LA, p = 0.17), whereas the median number of days in hospital was shorter in the LA group (4 in GA and 2 in LA, p <0.001). No emergency conversions to GA were performed in the LA group and only 1 patient needed admission to a high dependency (HD) unit. In conclusion, performing a TAVR under LA is at least as safe as GA. In addition, there is a reduced procedural time and length of hospital stay. LA is a safe and cost-effective alternative to GA and patients can be safely transferred to a low dependency unit. Crown Copyright (C) 2016 Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1712 / 1716
页数:5
相关论文
共 10 条
[1]   Comparison of Transfemoral Transcatheter Aortic Valve Replacement Performed in the Catheterization Laboratory (Minimalist Approach) Versus Hybrid Operating Room (Standard Approach) Outcomes and Cost Analysis [J].
Babaliaros, Vasilis ;
Devireddy, Chandan ;
Lerakis, Stamatios ;
Leonardi, Robert ;
Iturra, Sebastian A. ;
Mavromatis, Kreton ;
Leshnower, Bradley G. ;
Guyton, Robert A. ;
Kanitkar, Mihir ;
Keegan, Patricia ;
Simone, Amy ;
Stewart, James P. ;
Ghasemzadeh, Nima ;
Block, Peter ;
Thourani, Vinod H. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (08) :898-904
[2]   Treatment of calcific aortic stenosis with the percutaneous heart valve - Mid-term follow-up from the initial feasibility studies: The French experience [J].
Cribier, A ;
Eltchaninoff, H ;
Tron, C ;
Bauer, F ;
Agatiello, C ;
Nercolini, D ;
Tapiero, S ;
Litzler, PY ;
Bessou, JP ;
Babaliaros, V .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (06) :1214-1223
[3]   Feasibility and Safety of Early Discharge After Transfemoral Transcatheter Aortic Valve Implantation With the Edwards SAPIEN-XT Prosthesis [J].
Durand, Eric ;
Eltchaninoff, Helene ;
Canville, Alexandre ;
Bouhzam, Najime ;
Godin, Matthieu ;
Tron, Christophe ;
Rodriguez, Carlos ;
Litzler, Pierre-Yves ;
Bauer, Fabrice ;
Cribier, Alain .
AMERICAN JOURNAL OF CARDIOLOGY, 2015, 115 (08) :1116-1122
[4]   Transcutaneous aortic valve replacement with the Edwards SAPIEN XT and Medtronic CoreValve prosthesis under fluoroscopic guidance and local anaesthesia only [J].
Greif, Martin ;
Lange, Philipp ;
Naebauer, Michael ;
Schwarz, Florian ;
Becker, Christoph ;
Schmitz, Christoph ;
Pohl, Tilmann ;
D'Anastasi, Melvin ;
Boekstegers, Peter ;
Massberg, Steffen ;
Kupatt, Christian .
HEART, 2014, 100 (09) :691-695
[5]   Percutaneous aortic valve replacement for severe aortic stenosis in high-rick patients using the second- and current third-generation self-expanding CoreValve prosthesis - Device success and 30-day clinical outcome [J].
Grube, Eberhard ;
Schuler, Gerhard ;
Buellesfeld, Lutz ;
Gerckens, Ulrich ;
Linke, Axel ;
Wenaweser, Peter ;
Sauren, Barthel ;
Mohr, Friedrich-Wilhelm ;
Walther, Thomas ;
Zickmann, Bernfried ;
Iversen, Stein ;
Felderhoff, Thomas ;
Cartier, Raymond ;
Bonan, Raoul .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (01) :69-76
[6]   Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortium [J].
Leon, Martin B. ;
Piazza, Nicolo ;
Nikolsky, Eugenia ;
Blackstone, Eugene H. ;
Cutlip, Donald E. ;
Kappetein, Arie Pieter ;
Krucoff, Mitchell W. ;
Mack, Michael ;
Mehran, Roxana ;
Miller, Craig ;
Morel, Marie-Angele ;
Petersen, John ;
Popma, Jeffrey J. ;
Takkenberg, Johanna J. M. ;
Vahanian, Alec ;
van Es, Gerrit-Anne ;
Vranckx, Pascal ;
Webb, John G. ;
Windecker, Stephan ;
Serruys, Patrick W. .
EUROPEAN HEART JOURNAL, 2011, 32 (02) :205-U144
[7]   Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery. [J].
Leon, Martin B. ;
Smith, Craig R. ;
Mack, Michael ;
Miller, D. Craig ;
Moses, Jeffrey W. ;
Svensson, Lars G. ;
Tuzcu, E. Murat ;
Webb, John G. ;
Fontana, Gregory P. ;
Makkar, Raj R. ;
Brown, David L. ;
Block, Peter C. ;
Guyton, Robert A. ;
Pichard, Augusto D. ;
Bavaria, Joseph E. ;
Herrmann, Howard C. ;
Douglas, Pamela S. ;
Petersen, John L. ;
Akin, Jodi J. ;
Anderson, William N. ;
Wang, Duolao ;
Pocock, Stuart .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (17) :1597-1607
[8]   Clinical Outcomes and Safety of Transfemoral Aortic Valve Implantation Under General Versus Local Anesthesia Subanalysis of the French Aortic National CoreValve and Edwards 2 Registry [J].
Oguri, Atsushi ;
Yamamoto, Masanori ;
Mouillet, Gauthier ;
Gilard, Martine ;
Laskar, Marc ;
Eltchaninoff, Helene ;
Fajadet, Jean ;
Iung, Bernard ;
Donzeau-Gouge, Patrick ;
Leprince, Pascal ;
Leguerrier, Alain ;
Prat, Alain ;
Lievre, Michel ;
Chevreul, Karine ;
Dubois-Rande, Jean-Luc ;
Chopard, Romain ;
Van Belle, Eric ;
Otsuka, Toshiaki ;
Teiger, Emmanuel .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (04) :602-610
[9]   Multicenter Evaluation of a Next-Generation Balloon-Expandable Transcatheter Aortic Valve [J].
Webb, John ;
Gerosa, Gino ;
Lefevre, Thierry ;
Leipsic, Jonathon ;
Spence, Mark ;
Thomas, Martyn ;
Thielmann, Matthias ;
Treede, Hendrik ;
Wendler, Olaf ;
Walther, Thomas .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (21) :2235-2243
[10]   Percutaneous transarterial aortic valve replacement in selected high-risk patients with aortic stenosis [J].
Webb, John G. ;
Pasupati, Sanjeevan ;
Humphries, Karin ;
Thompson, Christopher ;
Altwegg, Lukas ;
Moss, Robert ;
Sinhal, Ajay ;
Carere, Ronald G. ;
Munt, Brad ;
Ricci, Donald ;
Ye, Jian ;
Cheung, Anson ;
Lichtenstein, Sam V. .
CIRCULATION, 2007, 116 (07) :755-763