Advances in myelin imaging with potential clinical application to pediatric imaging

被引:31
作者
Spader, Heather S. [1 ]
Ellermeier, Anna [2 ]
O'Muircheartaigh, Jonathan [3 ,4 ]
Dean, Douglas C., III [3 ]
Dirks, Holly [3 ]
Boxerman, Jerrold L. [2 ]
Cosgrove, G. Rees [1 ]
Deoni, Sean C. L. [3 ]
机构
[1] Brown Univ, Rhode Isl Hosp, Dept Neurosurg, Warren Alpert Med Sch, Providence, RI 02903 USA
[2] Brown Univ, Rhode Isl Hosp, Dept Diagnost Imaging, Warren Alpert Med Sch, Providence, RI 02903 USA
[3] Brown Univ, Adv Baby Imaging Lab, Sch Engn, Providence, RI 02912 USA
[4] Kings Coll London, Dept Neuroimaging Sci, Inst Psychiat, London WC2R 2LS, England
基金
英国医学研究理事会; 英国惠康基金;
关键词
myelin; epilepsy; imaging; multicomponent relaxometry; MULTIPLE-SCLEROSIS; WHITE-MATTER; DIFFUSION; BRAIN; T-2; MODEL; MRI;
D O I
10.3171/2013.1.FOCUS12426
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
White matter development and myelination are critical processes in neurodevelopment. Myelinated white matter facilitates the rapid and coordinated brain messaging required for higher-order cognitive and behavioral processing. Whereas several neurological disorders such as multiple sclerosis are associated with gross white matter damage and demyelination, other disorders such as epilepsy may involve altered myelination in the efferent or afferent white matter pathways adjoining epileptic foci. Current MRI techniques including T1 weighting, T2 weighting, FLAIR, diffusion tensor imaging, and MR spectroscopy permit visualization of gross white matter abnormalities and evaluation of underlying white matter fiber architecture and integrity, but they provide only qualitative information regarding myelin content. Quantification of these myelin changes could provide new insight into disease severity and prognosis, reveal information regarding spatial location of foci or lesions and the associated affected neural systems, and create a metric to evaluate treatment efficacy. Multicomponent analysis of T1 and T2 relaxation data, or multicomponent relaxometry (MCR), is a quantitative imaging technique that is sensitive and specific to myelin content alteration. In the past, MCR has been associated with lengthy imaging times, but a new, faster MCR technique (mcDESPOT) has made quantitative analysis of myelin content more accessible for clinical research applications. The authors briefly summarize traditional white matter imaging techniques, describe MCR and mcDESPOT, and discuss current and future clinical applications of MCR, with a particular focus on pediatric epilepsy. (http://thejns.org/doi/abs/10.3171/2013.1.FOCUS12426)
引用
收藏
页数:7
相关论文
共 22 条
[1]  
Barkovich AJ, 2000, PEDIAT NEUROIMAGING, P30
[2]   Diffusion-tensor MRI: theory, experimental design and data analysis - a technical review [J].
Basser, PJ ;
Jones, DK .
NMR IN BIOMEDICINE, 2002, 15 (7-8) :456-467
[3]   The basis of anisotropic water diffusion in the nervous system - a technical review [J].
Beaulieu, C .
NMR IN BIOMEDICINE, 2002, 15 (7-8) :435-455
[4]   Neuronal correlates of the five factor model (FFM) of human personality: Multimodal imaging in a large healthy sample [J].
Bjornebekk, Astrid ;
Fjell, Anders M. ;
Walhovd, Kristine B. ;
Grydeland, Hakon ;
Torgersen, Svenn ;
Westlye, Lars T. .
NEUROIMAGE, 2013, 65 :194-208
[5]  
Cataltepe O, 2010, PEDIATRIC EPILEPSY S
[6]   Standardized structural magnetic resonance imaging in multicentre studies using quantitative T1 and T2 imaging at 1.5 T [J].
Deoni, Sean C. L. ;
Williams, Steven C. R. ;
Jezzard, Peter ;
Suckling, John ;
Murphy, Declan G. M. ;
Jones, Derek K. .
NEUROIMAGE, 2008, 40 (02) :662-671
[7]   Investigating white matter development in infancy and early childhood using myelin water faction and relaxation time mapping [J].
Deoni, Sean C. L. ;
Dean, Douglas C., III ;
O'Muircheartaigh, Jonathan ;
Dirks, Holly ;
Jerskey, Beth A. .
NEUROIMAGE, 2012, 63 (03) :1038-1053
[8]   Mapping Infant Brain Myelination with Magnetic Resonance Imaging [J].
Deoni, Sean C. L. ;
Mercure, Evelyne ;
Blasi, Anna ;
Gasston, David ;
Thomson, Alex ;
Johnson, Mark ;
Williams, Steven C. R. ;
Murphy, Declan G. M. .
JOURNAL OF NEUROSCIENCE, 2011, 31 (02) :784-791
[9]   Correction of Main and Transmit Magnetic Field (B0 and B1) Inhomogeneity Effects in Multicomponent-Driven Equilibrium Single-Pulse Observation of T1 and T2 [J].
Deoni, Sean C. L. .
MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (04) :1021-1035
[10]   Gleaning Multicomponent T1 and T2 Information From Steady-State Imaging Data [J].
Deoni, Sean C. L. ;
Rutt, Brian K. ;
Arun, Tarunya ;
Pierpaoli, Carlo ;
Jones, Derek K. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (06) :1372-1387