AN EXPERIMENTAL EVALUATION OF THERMAL STRATIFICATION IN A FAN-VENTILATED GREENHOUSE

被引:0
|
作者
Li, S. [1 ]
Willits, D. H. [1 ]
机构
[1] N Carolina State Univ, Weaver Labs 112, Dept Biol & Agr Engn, Raleigh, NC 27695 USA
关键词
Evaporative cooling; Fan ventilation; Greenhouse; Thermal stratification;
D O I
暂无
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
Experiments were performed to investigate air velocity and vertical air temperature distributions in a fan-ventilated greenhouse. The effects of ventilation rate and canopy size on the allocation of airflow between canopy and non-canopy areas were examined. The data suggested that the ratio of the air velocity within the canopy to the mean velocity of the entire greenhouse cross-section depended on not only the area ratio of canopy to greenhouse cross-section, but also ventilation rate. The ratio of canopy air velocity to greenhouse average velocity decreased if ventilation rate increased The effects of outside solar radiation, ventilation rate, evaporative cooling pads, and presence of a canopy on the vertical air temperature variations were also investigated. The vertical air temperature variation increased approximately linearly with solar radiation. Use of an evaporative pad increased the temperature variation. Increasing ventilation rate resulted in reduced air temperature variation. The presence of a canopy modified the vertical temperature distribution and reduced temperature variations as well.
引用
收藏
页码:1443 / 1448
页数:6
相关论文
共 50 条
  • [21] The experimental investigation of the thermal stratification in a solar hot water tank
    Wang, Zilong
    Zhang, Hua
    Huang, Huajie
    Dou, Binlin
    Huang, Xiuhui
    Goula, Maria A.
    RENEWABLE ENERGY, 2019, 134 : 862 - 874
  • [22] Thermal modelling and experimental validation of ground temperature distribution in greenhouse
    Ghosal, MK
    Tiwari, GN
    Srivastava, NSL
    Sodha, MS
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2004, 28 (01) : 45 - 63
  • [23] Solar energy conservation in greenhouse: Thermal analysis and experimental validation
    Mobtaker, Hassan Ghasemi
    Ajabshirchi, Yahya
    Ranjbar, Seyed Faramarz
    Matloobi, Mansour
    RENEWABLE ENERGY, 2016, 96 : 509 - 519
  • [24] A Comparison between Experimental and CFD Results with Regard to Flow Patterns and Ventilation Rate of a Naturally Ventilated Greenhouse
    Liran, O.
    Teitel, M.
    Ziskind, G.
    Letan, R.
    PROCEEDINGS OF THE INTERNATIONAL SYMPOSIUM ON HIGH TECHNOLOGY FOR GREENHOUSE SYSTEM MANAGEMENT, VOLS 1 AND 2, 2008, (801): : 917 - +
  • [25] Thermal modelling of asymmetric overlap roof greenhouse with experimental validation
    Sethi, V. P.
    INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2019, 38 (01) : 24 - 36
  • [26] Investigation of thermal environment in greenhouse based on fan coil unit forced-air heating system
    Wang, Qian
    Guo, Zeyu
    Ji, Hengsong
    Cheng, Shan
    Zhang, Chengcheng
    Nongye Jixie Xuebao/Transactions of the Chinese Society for Agricultural Machinery, 2013, 44 (08): : 219 - 223
  • [27] The Thermal Stratification Evaluation of Phase-Change Materials in a Heat Storage Tank: Computational Fluid Dynamics and Experimental Study
    Wang, Zilong
    Zhang, Hua
    Dou, Binlin
    Zhang, Guanhua
    Huang, Huajie
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2020, 142 (02):
  • [28] Experimental investigation on thermal stratification in a pressurizer surge line with different arrangements
    Cai, Benan
    Weng, Yu
    Wang, Yanyan
    Qin, Xingchen
    Cao, Fangfang
    Gu, Hongfang
    Wang, Haijun
    PROGRESS IN NUCLEAR ENERGY, 2017, 98 : 239 - 247
  • [29] Experimental research on the effects of fluid and heater on thermal stratification of liquefied gas
    Shi, Jianyun
    Ren, Jingjie
    Liu, Peng
    Bi, Mingshu
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2013, 50 : 29 - 36
  • [30] Experimental and computational simulation of thermal stratification in large pools with immersed condenser
    Kumar, Sunil
    Vijayan, P. K.
    Kannan, Umasankari
    Sharma, Manish
    Pilkhwal, D. S.