Computations of Magnetic Field Anomalies in Synchronous Generator Due to Rotor Excitation Coil Faults

被引:10
作者
Fiser, Rastko [1 ]
Lavric, Henrik [1 ]
Bugeza, Miroslav [2 ]
Makuc, Danilo [1 ]
机构
[1] Univ Ljubljana, Fac Elect Engn, Ljubljana 1000, Slovenia
[2] Elek Svetovanje Doo, Ljubljana 1000, Slovenia
关键词
Failure analysis; finite element method; magnetic field; synchronous generator excitation; turbo generator;
D O I
10.1109/TMAG.2013.2244864
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper presents an approach to model shorted turns in rotor excitation winding of synchronous generator using finite element analysis. It enables detailed examination of magnetic field at several operating conditions under healthy and faulty states which are difficult or even impossible to carry out by available measurement methods in industrial environment. It is confirmed that an extensive analysis should be performed to assure accurate healthy/faulty state predictions, since the level of diagnostic signal is considerably influenced by a combination of many machine design and operating parameters.
引用
收藏
页码:2303 / 2306
页数:4
相关论文
共 15 条
[1]  
Albright D. R., 1971, IEEE T POWER APPARAT, V90, P28
[2]  
Bianchi N., 2005, Electrical Machine Analysis Using Finite Elements
[3]   Interturn Stator Faults Analysis of a 200-MVA Hydrogenerator During Transient Operation Using FEM [J].
Dallas, Stefanos E. ;
Safacas, Athanasios N. ;
Kappatou, Joya C. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (04) :1151-1160
[4]   Analytical Model of Permeance Variation Losses in Permanent Magnets of the Multipole Synchronous Machine [J].
Gotovac, Gorazd ;
Lampic, Gorazd ;
Miljavec, Damijan .
IEEE TRANSACTIONS ON MAGNETICS, 2013, 49 (02) :921-928
[5]   Steady-State Calculation and Online Monitoring of Interturn Short Circuit of Field Windings in Synchronous Machines [J].
Hao, Liangliang ;
Sun, Yuguang ;
Qiu, Arui ;
Wang, Xiangheng .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2012, 27 (01) :128-138
[6]  
Kerszenbaum I., 1996, Inspection of Large Synchronous Machines: Checklists, Failure Identification, and Troubleshooting
[7]   CALCULATION OF INTERNAL FAULT CURRENTS IN SYNCHRONOUS MACHINES [J].
KINITSKY, VA .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1965, PA84 (05) :381-&
[8]  
Klempner G., 2008, Handbook of large turbo-generator operation and maintenance, V2
[9]  
Penman J., 1996, ELECT POWER, P137
[10]   FLUX MONITORING IMPROVEMENT For online condition monitoring of turbine generator rotors [J].
Sasic, Mladen ;
Campbell, S. R. ;
Lloyd, Blake .
IEEE INDUSTRY APPLICATIONS MAGAZINE, 2011, 17 (05) :66-69