Is the European System for Cardiac Operative Risk Evaluation model valid for estimating the operative risk of patients considered for percutaneous aortic valve replacement?

被引:84
作者
Brown, Morgan L. [1 ]
Schaff, Hartzell V. [1 ]
Sarano, Maurice E. [2 ]
Li, Zhuo [3 ]
Sundt, Thoralf M. [1 ]
Dearani, Joseph A. [1 ]
Mullany, Charles J. [1 ]
Orszulak, Thomas A. [1 ]
机构
[1] Mayo Clin, Div Cardiovasc Surg, Rochester, MN 55905 USA
[2] Mayo Clin, Div Cardiovasc Med, Rochester, MN 55905 USA
[3] Mayo Clin, Div Biostat, Rochester, MN 55905 USA
关键词
D O I
10.1016/j.jtcvs.2007.10.091
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The European System for Cardiac Operative Risk Evaluation has been used to define a particularly high-risk group of patients for aortic valve replacement in whom alternative procedures, such as stent-mounted percutaneous valve procedures, may be appropriate. Our objective was to assess the validity of this risk assessment at a large-volume, tertiary cardiac surgical center. Methods: From January 1, 2000, to December 30, 2006, a total of 1177 patients underwent isolated aortic valve replacement at the Mayo Clinic. Patient and operative demographics were recorded in a prospective database. Early mortality (<= 30 days) was obtained. Additive and logistic European System for Cardiac Operative Risk Evaluations were calculated for each patient. Results: The mean patient age was 68.0 years (+/- 14.7 years) at the time of surgery, and 36.8% were female. Variables used in the calculation of the European System for Cardiac Operative Risk Evaluation included chronic lung disease (15% of our cohort), extracardiac arteriopathy (13.8%), neurologic dysfunction (0.2%), previous cardiac surgery (23.2%), renal failure (6.5%), active endocarditis (3.1%), recent myocardial infarction (1.1%), unstable angina (0.1%), and severe pulmonary hypertension (6.5%). The ejection fraction was severely reduced (<= 30%) in 4.9% of patients and moderately reduced (<= 50%) in 12.7% of patients. One percent of patients were in a critical state, and operation was performed urgently in 3.4% of patients. Although mean mortality estimates were 6.9% +/- 3.4% (additive European System for Cardiac Operative Risk Evaluation) and 10.9% +/- 12.7% (logistic European System for Cardiac Operative Risk Evaluation), actual overall operative mortality in our patients was 2.5%. Additive and logistic European System for Cardiac Operative Risk Evaluations overestimated operative mortality in low, intermediate, and high-risk subgroups by up to 17.8%. Conclusions: The European System for Cardiac Operative Risk Evaluation should not be used to determine the operability of patients for isolated aortic valve replacement. Elevated European System for Cardiac Operative Risk Evaluations alone do not appropriately define a population for use of a percutaneous aortic valve.
引用
收藏
页码:566 / 571
页数:6
相关论文
共 16 条
  • [1] Percutaneous aortic valve implantation: A case report
    Chandavimol, Mann
    McClure, Samuel J.
    Carere, Ron G.
    Thompson, Christopher R.
    Ricci, Donald R.
    Mackay, Martha H.
    Webb, John G.
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2006, 22 (13) : 1159 - 1161
  • [2] Percutaneous aortic valve replacement for severe aortic stenosis in high-rick patients using the second- and current third-generation self-expanding CoreValve prosthesis - Device success and 30-day clinical outcome
    Grube, Eberhard
    Schuler, Gerhard
    Buellesfeld, Lutz
    Gerckens, Ulrich
    Linke, Axel
    Wenaweser, Peter
    Sauren, Barthel
    Mohr, Friedrich-Wilhelm
    Walther, Thomas
    Zickmann, Bernfried
    Iversen, Stein
    Felderhoff, Thomas
    Cartier, Raymond
    Bonan, Raoul
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (01) : 69 - 76
  • [3] Percutaneous implantation of the CoreValve self-expanding valve prosthesis in high-risk patients with aortic valve disease - The Siegburg First-in-Man Study
    Grube, Eberhard
    Laborde, Jean C.
    Gerckens, Ulrich
    Felderhoff, Thomas
    Sauren, Barthel
    Buellesfeld, Lutz
    Mueller, Ralf
    Menichelli, Maurizio
    Schmidt, Thomas
    Zickmann, Bernfried
    Iversen, Stein
    Stone, Gregg W.
    [J]. CIRCULATION, 2006, 114 (15) : 1616 - 1624
  • [4] Hariharan Seetharaman, 2006, Curr Surg, V63, P226
  • [5] Transapical transcatheter aortic valve implantation in humans - Initial clinical experience
    Lichtenstein, Samuel V.
    Cheung, Anson
    Ye, Jian
    Thompson, Christopher R.
    Carere, Ronald G.
    Pasupati, Sanjeevan
    Webb, John G.
    [J]. CIRCULATION, 2006, 114 (06) : 591 - 596
  • [6] Early mortality in coronary bypass surgery:: The EuroSCORE versus the Society of Thoracic Surgeons risk algorithm
    Nilsson, J
    Algotsson, L
    Höglund, P
    Lührs, C
    Brandt, J
    [J]. ANNALS OF THORACIC SURGERY, 2004, 77 (04) : 1235 - 1240
  • [7] RAMSAY G, 1988, SURG RES COMM, V3, P9
  • [8] Risk factors and outcome in European cardiac surgery: analysis of the EuroSCORE multinational database of 19030 patients
    Roques, F
    Nashef, SAM
    Michel, P
    Gauducheau, E
    de Vincentiis, C
    Baudet, E
    Cortina, J
    David, M
    Faichney, A
    Gabrielle, F
    Gams, E
    Harjula, A
    Jones, MT
    Pintor, PP
    Salamon, R
    Thulin, L
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1999, 15 (06) : 816 - 822
  • [9] The logistic EuroSCORE
    Roques, F
    Michel, P
    Goldstone, AR
    Nashef, SAM
    [J]. EUROPEAN HEART JOURNAL, 2003, 24 (09) : 881 - 882
  • [10] Single centre, single domain validation of the EuroSCORE on a consecutive sample of primary and repeat CABG
    Sergeant, P
    de Worm, E
    Meyns, B
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2001, 20 (06) : 1176 - 1182