In vitro evaluation of the imaging accuracy of C-arm conebeam CT in cerebral perfusion imaging

被引:4
|
作者
Ganguly, A. [1 ]
Fieselmann, A. [2 ,3 ,4 ]
Boese, J. [4 ]
Rohkohl, C. [2 ,4 ]
Hornegger, J. [2 ,3 ]
Fahrig, R. [1 ]
机构
[1] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[2] Univ Erlangen Nurnberg, Dept Comp Sci, Pattern Recognit Lab, D-91058 Erlangen, Germany
[3] Univ Erlangen Nurnberg, Erlangen Grad Sch Adv Opt Technol SAOT, D-91058 Erlangen, Germany
[4] Siemens AG, Healthcare Sect, D-91301 Forchheim, Germany
基金
美国国家卫生研究院;
关键词
perfusion CT; C-arm; conebeam CT; interventional imaging; x-ray; arterial input function; venous input function; sinusoid; HIGH-RESOLUTION MEASUREMENT; TRACER BOLUS PASSAGES; RECONSTRUCTION; STROKE;
D O I
10.1118/1.4757910
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The authors have developed a method to enable cerebral perfusion CT imaging using C-arm based conebeam CT (CBCT). This allows intraprocedural monitoring of brain perfusion during treatment of stroke. Briefly, the technique consists of acquiring multiple scans (each scan comprised of six sweeps) acquired at different time delays with respect to the start of the x-ray contrast agent injection. The projections are then reconstructed into angular blocks and interpolated at desired time points. The authors have previously demonstrated its feasibility in vivo using an animal model. In this paper, the authors describe an in vitro technique to evaluate the accuracy of their method for measuring the relevant temporal signals. Methods: The authors' evaluation method is based on the concept that any temporal signal can be represented by a Fourier series of weighted sinusoids. A sinusoidal phantom was developed by varying the concentration of iodine as successive steps of a sine wave. Each step corresponding to a different dilution of iodine contrast solution contained in partitions along a cylinder. By translating the phantom along the axis at different velocities, sinusoidal signals at different frequencies were generated. Using their image acquisition and reconstruction algorithm, these sinusoidal signals were imaged with a C-arm system and the 3D volumes were reconstructed. The average value in a slice was plotted as a function of time. The phantom was also imaged using a clinical CT system with 0.5 s rotation. C-arm CBCT results using 6, 3, 2, and 1 scan sequences were compared to those obtained using CT. Data were compared for linear velocities of the phantom ranging from 0.6 to 1 cm/s. This covers the temporal frequencies up to 0.16 Hz corresponding to a frequency range within which 99% of the spectral energy for all temporal signals in cerebral perfusion imaging is contained. Results: The errors in measurement of temporal frequencies are mostly below 2% for all multiscan sequences. For single scan sequences, the errors increase sharply beyond 0.10 Hz. The amplitude errors increase with frequency and with decrease in the number of scans used. Conclusions: Our multiscan perfusion CT approach allows low errors in signal frequency measurement. Increasing the number of scans reduces the amplitude errors. A two-scan sequence appears to offer the best compromise between accuracy and the associated total x-ray and iodine dose. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4757910]
引用
收藏
页码:6652 / 6659
页数:8
相关论文
共 50 条
  • [41] An Enhanced SMART-RECON Algorithm for Time-Resolved C-Arm Cone-Beam CT Imaging
    Li, Yinsheng
    Garrett, John W.
    Li, Ke
    Strother, Charles
    Chen, Guang-Hong
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (06) : 1894 - 1905
  • [42] Atlas-Based Image Reconstruction for Breast CT Imaging Using Non-Isocentric C-Arm Scanner
    Rashed, Essam A.
    Kudo, Hiroyuki
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [43] Development of learning-based online C-arm CT imaging technique for image-guided adaptive brachytherapy
    Lee, Minjae
    Lee, Hunwoo
    Cho, Hyosung
    Sung, Searom
    Kim, Hyemi
    Choi, Chang Heon
    Choi, Hyun Joon
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1064
  • [44] C-arm CT imaging with the extended line-ellipse-line trajectory: first implementation on a state-of-the-art robotic angiography system
    Guo, Zijia
    Lauritsch, Guenter
    Maier, Andreas
    Kugler, Patrick
    Islam, Mohammad
    Vogt, Florian
    Noo, Frederic
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (18)
  • [45] C-Arm CT Measurement of Cerebral Blood Volume in Ischemic Stroke: An Experimental Study in Canines
    Bley, T.
    Strother, C. M.
    Pulfer, K.
    Royalty, K.
    Zellerhoff, M.
    Deuerling-Zheng, Y.
    Bender, F.
    Consigny, D.
    Yasuda, R.
    Niemann, D.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (03) : 536 - 540
  • [46] CT perfusion cerebral blood flow imaging in neurological critical care
    Mark R. Harrigan
    Jody Leonardo
    Kevin J. Gibbons
    Lee R. Guterman
    L. Nelson Hopkins
    Neurocritical Care, 2005, 2
  • [47] Truncation Correction for VOI C-arm CT using Scattered Radiation
    Bier, Bastian
    Maier, Andreas
    Hofmann, Hannes G.
    Schwemmer, Chris
    Xia, Yan
    Struffert, Tobias
    Hornegger, Joachim
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [48] A task-driven cerebral angiographic imaging based on CT perfusion
    Wang, Cheng
    Chen, Siqi
    Mi, Donghua
    FRONTIERS IN NEUROLOGY, 2024, 14
  • [49] CT perfusion cerebral blood flow imaging in neurological critical care
    Harrigan, MR
    Leonardo, J
    Gibbons, KJ
    Guterman, LR
    Hopkins, LN
    NEUROCRITICAL CARE, 2005, 2 (03) : 352 - 366
  • [50] CT Perfusion Imaging Pitfall Related to Fetal Posterior Cerebral Artery
    Raghuram, Karthikram
    Hou, Bob L.
    Roberts, Thomas D.
    Carpenter, Jeffrey S.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (06) : 1371 - 1374