In vitro evaluation of the imaging accuracy of C-arm conebeam CT in cerebral perfusion imaging

被引:4
|
作者
Ganguly, A. [1 ]
Fieselmann, A. [2 ,3 ,4 ]
Boese, J. [4 ]
Rohkohl, C. [2 ,4 ]
Hornegger, J. [2 ,3 ]
Fahrig, R. [1 ]
机构
[1] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[2] Univ Erlangen Nurnberg, Dept Comp Sci, Pattern Recognit Lab, D-91058 Erlangen, Germany
[3] Univ Erlangen Nurnberg, Erlangen Grad Sch Adv Opt Technol SAOT, D-91058 Erlangen, Germany
[4] Siemens AG, Healthcare Sect, D-91301 Forchheim, Germany
基金
美国国家卫生研究院;
关键词
perfusion CT; C-arm; conebeam CT; interventional imaging; x-ray; arterial input function; venous input function; sinusoid; HIGH-RESOLUTION MEASUREMENT; TRACER BOLUS PASSAGES; RECONSTRUCTION; STROKE;
D O I
10.1118/1.4757910
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The authors have developed a method to enable cerebral perfusion CT imaging using C-arm based conebeam CT (CBCT). This allows intraprocedural monitoring of brain perfusion during treatment of stroke. Briefly, the technique consists of acquiring multiple scans (each scan comprised of six sweeps) acquired at different time delays with respect to the start of the x-ray contrast agent injection. The projections are then reconstructed into angular blocks and interpolated at desired time points. The authors have previously demonstrated its feasibility in vivo using an animal model. In this paper, the authors describe an in vitro technique to evaluate the accuracy of their method for measuring the relevant temporal signals. Methods: The authors' evaluation method is based on the concept that any temporal signal can be represented by a Fourier series of weighted sinusoids. A sinusoidal phantom was developed by varying the concentration of iodine as successive steps of a sine wave. Each step corresponding to a different dilution of iodine contrast solution contained in partitions along a cylinder. By translating the phantom along the axis at different velocities, sinusoidal signals at different frequencies were generated. Using their image acquisition and reconstruction algorithm, these sinusoidal signals were imaged with a C-arm system and the 3D volumes were reconstructed. The average value in a slice was plotted as a function of time. The phantom was also imaged using a clinical CT system with 0.5 s rotation. C-arm CBCT results using 6, 3, 2, and 1 scan sequences were compared to those obtained using CT. Data were compared for linear velocities of the phantom ranging from 0.6 to 1 cm/s. This covers the temporal frequencies up to 0.16 Hz corresponding to a frequency range within which 99% of the spectral energy for all temporal signals in cerebral perfusion imaging is contained. Results: The errors in measurement of temporal frequencies are mostly below 2% for all multiscan sequences. For single scan sequences, the errors increase sharply beyond 0.10 Hz. The amplitude errors increase with frequency and with decrease in the number of scans used. Conclusions: Our multiscan perfusion CT approach allows low errors in signal frequency measurement. Increasing the number of scans reduces the amplitude errors. A two-scan sequence appears to offer the best compromise between accuracy and the associated total x-ray and iodine dose. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4757910]
引用
收藏
页码:6652 / 6659
页数:8
相关论文
共 50 条
  • [21] Automatic measurement of contrast bolus distribution in carotid arteries using a C-arm angiography system to support interventional perfusion imaging
    Fieselmann, Andreas
    Ganguly, Arundhuti
    Yu Deuerling-Zheng
    Boese, Jan
    Hornegger, Joachim
    Fahrig, Rebecca
    MEDICAL IMAGING 2011: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2011, 7964
  • [22] Method for improving the accuracy of quantitative cerebral perfusion imaging
    Sakaie, KE
    Shin, W
    Curtin, KR
    McCarthy, RM
    Cashen, TA
    Carroll, TJ
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (05) : 512 - 519
  • [23] Interventional C-Arm Tomosynthesis for Vascular Imaging: Initial Results
    Langan, David A.
    Claus, Bernhard E. H.
    Al Assad, Omar
    Trousset, Yves
    Riddell, Cyril
    Avignon, Gregoire
    Solomon, Stephen B.
    Lai, Hao
    Wang, Xin
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [24] Intravenous C-Arm Conebeam CT Angiography following Long-Term Flow-Diverter Implantation: Technologic Evaluation and Preliminary Results
    Yu, S. C. H.
    Lee, K. T.
    Lau, T. W. W.
    Wong, G. K. C.
    Pang, V. K. Y.
    Chan, K. Y.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (03) : 481 - 486
  • [25] Imaging Guidance with C-arm CT: Prospective Evaluation of Its Impact on Patient Radiation Exposure during Transhepatic Arterial Chemoembolization
    Kothary, Nishita
    Abdelmaksoud, Mohamed H. K.
    Tognolini, Alessia
    Fahrig, Rebecca
    Rosenberg, Jarrett
    Hovsepian, David M.
    Ganguly, Arundhuti
    Louie, John D.
    Kuo, William T.
    Hwang, Gloria L.
    Holzer, Alison
    Sze, Daniel Y.
    Hofmann, Lawrence V.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 22 (11) : 1535 - 1544
  • [26] Clinical Applications of Quantitative Perfusion Imaging with a C-Arm Flat-Panel Detector-A Systematic Review
    Al-Kaylani, Abdallah H. A. Zaid
    Schuurmann, Richte C. L.
    Maathuis, Wouter D.
    Slart, Riemer H. J. A.
    De Vries, Jean-Paul P. M.
    Bokkers, Reinoud P. H.
    DIAGNOSTICS, 2023, 13 (01)
  • [27] Soft-tissue imaging with C-arm cone-beam CT using statistical reconstruction
    Wang, Adam S.
    Stayman, J. Webster
    Otake, Yoshito
    Kleinszig, Gerhard
    Vogt, Sebastian
    Gallia, Gary L.
    Khanna, A. Jay
    Siewerdsen, Jeffrey H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (04) : 1005 - 1026
  • [28] C-Arm CT Measurement of Cerebral Blood Volume: An Experimental Study in Canines
    Ahmed, A. S.
    Zellerhoff, M.
    Strother, C. M.
    Pulfer, K. A.
    Redel, T.
    Deuerling-Zheng, Y.
    Royalty, K.
    Consigny, D.
    Niemann, D. B.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (05) : 917 - 922
  • [29] Dynamic intensity-weighted region of interest imaging for conebeam CT
    Pearson, Erik
    Pan, Xiaochuan
    Pelizzari, Charles
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2016, 24 (03) : 361 - 377
  • [30] Low Dose, Low Noise and High Resolution Volume of Interest (VOI) Imaging in C-Arm Flat-Detector CT
    Kolditz, Daniel
    Kyriakou, Yiannis
    Kalender, Willi A.
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622