In vitro evaluation of the imaging accuracy of C-arm conebeam CT in cerebral perfusion imaging

被引:4
|
作者
Ganguly, A. [1 ]
Fieselmann, A. [2 ,3 ,4 ]
Boese, J. [4 ]
Rohkohl, C. [2 ,4 ]
Hornegger, J. [2 ,3 ]
Fahrig, R. [1 ]
机构
[1] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[2] Univ Erlangen Nurnberg, Dept Comp Sci, Pattern Recognit Lab, D-91058 Erlangen, Germany
[3] Univ Erlangen Nurnberg, Erlangen Grad Sch Adv Opt Technol SAOT, D-91058 Erlangen, Germany
[4] Siemens AG, Healthcare Sect, D-91301 Forchheim, Germany
基金
美国国家卫生研究院;
关键词
perfusion CT; C-arm; conebeam CT; interventional imaging; x-ray; arterial input function; venous input function; sinusoid; HIGH-RESOLUTION MEASUREMENT; TRACER BOLUS PASSAGES; RECONSTRUCTION; STROKE;
D O I
10.1118/1.4757910
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The authors have developed a method to enable cerebral perfusion CT imaging using C-arm based conebeam CT (CBCT). This allows intraprocedural monitoring of brain perfusion during treatment of stroke. Briefly, the technique consists of acquiring multiple scans (each scan comprised of six sweeps) acquired at different time delays with respect to the start of the x-ray contrast agent injection. The projections are then reconstructed into angular blocks and interpolated at desired time points. The authors have previously demonstrated its feasibility in vivo using an animal model. In this paper, the authors describe an in vitro technique to evaluate the accuracy of their method for measuring the relevant temporal signals. Methods: The authors' evaluation method is based on the concept that any temporal signal can be represented by a Fourier series of weighted sinusoids. A sinusoidal phantom was developed by varying the concentration of iodine as successive steps of a sine wave. Each step corresponding to a different dilution of iodine contrast solution contained in partitions along a cylinder. By translating the phantom along the axis at different velocities, sinusoidal signals at different frequencies were generated. Using their image acquisition and reconstruction algorithm, these sinusoidal signals were imaged with a C-arm system and the 3D volumes were reconstructed. The average value in a slice was plotted as a function of time. The phantom was also imaged using a clinical CT system with 0.5 s rotation. C-arm CBCT results using 6, 3, 2, and 1 scan sequences were compared to those obtained using CT. Data were compared for linear velocities of the phantom ranging from 0.6 to 1 cm/s. This covers the temporal frequencies up to 0.16 Hz corresponding to a frequency range within which 99% of the spectral energy for all temporal signals in cerebral perfusion imaging is contained. Results: The errors in measurement of temporal frequencies are mostly below 2% for all multiscan sequences. For single scan sequences, the errors increase sharply beyond 0.10 Hz. The amplitude errors increase with frequency and with decrease in the number of scans used. Conclusions: Our multiscan perfusion CT approach allows low errors in signal frequency measurement. Increasing the number of scans reduces the amplitude errors. A two-scan sequence appears to offer the best compromise between accuracy and the associated total x-ray and iodine dose. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4757910]
引用
收藏
页码:6652 / 6659
页数:8
相关论文
共 50 条
  • [1] C-arm CT Perfusion Imaging in the Interventional Suite
    Fieselmann, Andreas
    Manhart, Michael
    CURRENT MEDICAL IMAGING, 2013, 9 (02) : 96 - 101
  • [2] Evaluating the Feasibility of C-arm CT for Brain Perfusion Imaging: An in vitro Study
    Ganguly, A.
    Fieselmann, A.
    Boese, J.
    Rohkohl, C.
    Hornegger, J.
    Fahrig, R.
    MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625
  • [3] Cerebral CT Perfusion Using an Interventional C-Arm Imaging System: Cerebral Blood Flow Measurements
    Ganguly, A.
    Fieselmann, A.
    Marks, M.
    Rosenberg, J.
    Boese, J.
    Deuerling-Zheng, Y.
    Straka, M.
    Zaharchuk, G.
    Bammer, R.
    Fahrig, R.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (08) : 1525 - 1531
  • [4] Circular tomosynthesis for neuro perfusion imaging on an interventional C-arm
    Claus, Bernhard E.
    Langan, David A.
    Al Assad, Omar
    Wang, Xin
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [5] C-Arm imaging for brachytherapy source reconstruction: Geometrical accuracy
    Fung, AYC
    MEDICAL PHYSICS, 2002, 29 (05) : 724 - 726
  • [6] Closed Sinusoid Trajectory for C-Arm CT Imaging
    Yang, Haiquan
    Li, Meihua
    Koizumi, Kazuhito
    Kudo, Hiroyuki
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3480 - 3484
  • [7] C-arm CT soft tissue 3-D imaging with a mobile C-arm
    Ritter, D
    Mitschke, M
    Graumann, R
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 3 - 6
  • [8] A Novel Temporal Recovery Technique to Enable Cone Beam CT Perfusion Imaging Using an Interventional C-Arm System
    Tang, Jie
    Xu, Min
    Niu, Kai
    Royalty, Kevin
    Pulfer, Kari
    Strother, Charles
    Chen, Guang-Hong
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [9] Automatic cable artifact removal for cardiac C-arm CT imaging
    Haase, C.
    Schaefer, D.
    Kim, M.
    Chen, S. J.
    Carroll, J.
    Eshuis, P.
    Doessel, O.
    Grass, M.
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [10] Comparison of Aortic Arch and Intravenous Contrast Injection Techniques for C-arm Cone Beam CT: Implications for Cerebral Perfusion Imaging in the Angiography Suite
    Klostranec, Jesse M.
    Ehtiati, Tina
    Rao, Swati
    Radvany, Martin G.
    ACADEMIC RADIOLOGY, 2013, 20 (04) : 509 - 518