Sensor Fusion on Structural Monitoring Data Analysis: Application to a Cable-Stayed Bridge

被引:5
作者
Zonta, Daniele [1 ]
Bruschetta, Federico [1 ]
Zandonini, Riccardo [1 ]
Pozzi, Matteo [2 ]
Ming-Wang [3 ]
Glisic, Branko [4 ]
Inaudi, Daniele [5 ]
Posenato, Daniele [5 ]
Yang-Zhao [6 ]
机构
[1] Univ Trento, DICAM, Via Mesiano 77, I-38050 Trento, Italy
[2] Carnegie Mellon Univ, Pittsburgh, PA 15213 USA
[3] Northeastern Univ, Boston, MA 02115 USA
[4] Princeton Univ, Princeton, NJ 08544 USA
[5] Smartec SA, CH-6928 Manno, Switzerland
[6] Intelligent Instrument Syst, Burr Ridge, IL USA
来源
DAMAGE ASSESSMENT OF STRUCTURES X, PTS 1 AND 2 | 2013年 / 569-570卷
关键词
Bayesian inference; fiber optic sensors; elasto-magnetic sensors; Cable-Stayed bridge;
D O I
10.4028/www.scientific.net/KEM.569-570.812
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper illustrates an application of Bayesian logic to monitoring data analysis and structural condition state inference. The case study is a 260 m long cable-stayed bridge spanning the Adige River 10 km north of the town of Trento, Italy. This is a statically indeterminate structure, having a composite steel-concrete deck, supported by 12 stay cables. Structural redundancy, possible relaxation losses and an as-built condition differing from design, suggest that long-term load redistribution between cables can be expected. To monitor load redistribution, the owner decided to install a monitoring system which combines built-on-site elasto-magnetic and fiber-optic sensors. In this note, we discuss a rational way to improve the accuracy of the load estimate from the EM sensors taking advantage of the FOS information. More specifically, we use a multi-sensor Bayesian data fusion approach which combines the information from the two sensing systems with the prior knowledge, including design information and the outcomes of laboratory calibration. Using the data acquired to date, we demonstrate that combining the two measurements allows a more accurate estimate of the cable load, to better than 50 kN
引用
收藏
页码:812 / +
页数:2
相关论文
共 50 条
  • [21] IDENTIFICATION OF EXTREME DYNAMIC LOADS TO CABLE-STAYED BRIDGE BASED ON MONITORING DATA
    Sun, Li-Min
    Dong, Sheng
    ISISS '2009: INNOVATION & SUSTAINABILITY OF STRUCTURES, VOLS 1 AND 2, 2009, : 943 - 948
  • [22] Hybrid Wireless Smart Sensor Network for Full-scale Structural Health Monitoring of a Cable-stayed Bridge
    Jo, Hongki
    Sim, Sung-Han
    Mechitov, Kirill A.
    Kim, Robin
    Li, Jian
    Moinzadeh, Parya
    Spencer, B. F., Jr.
    Park, Jong Woong
    Cho, Soojin
    Jung, Hyung-Jo
    Yun, Chung-Bang
    Rice, Jennifer A.
    Nagayama, Tomonori
    SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2011, 2011, 7981
  • [23] A cointegration approach for cable anomaly warning based on structural health monitoring data: An application to cable-stayed bridges
    Fan, Zi-Yuan
    Huang, Qiao
    Ren, Yuan
    Zhu, Zhi-Yuan
    Xu, Xiang
    ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (13) : 2789 - 2802
  • [24] Structural analysis method in adjusting cable forces for a cable-stayed bridge by virtual temperature load and its application
    Wei, Chenglong
    Tang, Cuiping
    Wang, Guanghui
    TRANSFERABILITY AND APPLICABILITY OF CURRENT MECHANICS APPROACHES, 2009, : 97 - 101
  • [25] Cable-stayed bridge seismic fragility analysis
    Yuan, W. (yuan@tongji.edu.cn), 2013, Science Press (41): : 970 - 976
  • [26] Implementation of Wireless Sensor Network for Continuous Seismic Monitoring of Isolated Cable-Stayed Bridge
    Siringoringo, Dionysius M.
    Fujino, Yozo
    Suzuki, Makoto
    Mehta, Vaibhav
    JOURNAL OF BRIDGE ENGINEERING, 2022, 27 (04)
  • [27] Structural health monitoring system of a cable-stayed bridge using a dense array of scalable smart sensor network
    Cho, Soojin
    Jang, Shin Ae
    Jo, Hongki
    Mechitov, Kirill
    Rice, Jennifer A.
    Jung, Hyung-Jo
    Yun, Chung-Bang
    Spencer, Billie F., Jr.
    Nagayama, Tomonori
    Seo, Juwon
    SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2010, 2010, 7647
  • [28] Bifurcation and Chaotic Analysis for Cable Vibration of a Cable-Stayed Bridge
    Gao, Fabao
    Wang, Ruifang
    Lai, S. K.
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2020, 20 (02)
  • [29] Insights into temperature effects on structural deformation of a cable-stayed bridge based on structural health monitoring
    Zhou, Yi
    Sun, Limin
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2019, 18 (03): : 778 - 791
  • [30] Structural Monitoring and Field Test for Kao Ping Hsi Cable-Stayed Bridge in Taiwan
    Chen, Chern-Hwa
    ISCM II AND EPMESC XII, PTS 1 AND 2, 2010, 1233 : 1231 - 1236