Sensor Fusion on Structural Monitoring Data Analysis: Application to a Cable-Stayed Bridge

被引:5
作者
Zonta, Daniele [1 ]
Bruschetta, Federico [1 ]
Zandonini, Riccardo [1 ]
Pozzi, Matteo [2 ]
Ming-Wang [3 ]
Glisic, Branko [4 ]
Inaudi, Daniele [5 ]
Posenato, Daniele [5 ]
Yang-Zhao [6 ]
机构
[1] Univ Trento, DICAM, Via Mesiano 77, I-38050 Trento, Italy
[2] Carnegie Mellon Univ, Pittsburgh, PA 15213 USA
[3] Northeastern Univ, Boston, MA 02115 USA
[4] Princeton Univ, Princeton, NJ 08544 USA
[5] Smartec SA, CH-6928 Manno, Switzerland
[6] Intelligent Instrument Syst, Burr Ridge, IL USA
来源
DAMAGE ASSESSMENT OF STRUCTURES X, PTS 1 AND 2 | 2013年 / 569-570卷
关键词
Bayesian inference; fiber optic sensors; elasto-magnetic sensors; Cable-Stayed bridge;
D O I
10.4028/www.scientific.net/KEM.569-570.812
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper illustrates an application of Bayesian logic to monitoring data analysis and structural condition state inference. The case study is a 260 m long cable-stayed bridge spanning the Adige River 10 km north of the town of Trento, Italy. This is a statically indeterminate structure, having a composite steel-concrete deck, supported by 12 stay cables. Structural redundancy, possible relaxation losses and an as-built condition differing from design, suggest that long-term load redistribution between cables can be expected. To monitor load redistribution, the owner decided to install a monitoring system which combines built-on-site elasto-magnetic and fiber-optic sensors. In this note, we discuss a rational way to improve the accuracy of the load estimate from the EM sensors taking advantage of the FOS information. More specifically, we use a multi-sensor Bayesian data fusion approach which combines the information from the two sensing systems with the prior knowledge, including design information and the outcomes of laboratory calibration. Using the data acquired to date, we demonstrate that combining the two measurements allows a more accurate estimate of the cable load, to better than 50 kN
引用
收藏
页码:812 / +
页数:2
相关论文
共 50 条
  • [1] Analysis of monitoring data from cable-stayed bridge using sensor fusion techniques
    Zonta, Daniele
    Bruschetta, Federico
    Zandonini, Riccardo
    Pozzi, Matteo
    Wang, Ming
    Zhao, Yang
    Inaudi, Daniele
    Posenato, Daniele
    Glisic, Branko
    SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2013, 2013, 8692
  • [2] Fusion of monitoring data from cable-stayed bridge
    Bruschetta, F.
    Zonta, D.
    Cappello, C.
    Zandonini, R.
    Inaudi, D.
    Posenato, D.
    Pozzi, M.
    Wang, M. L.
    Glisic, B.
    Zhao, Y.
    2013 IEEE WORKSHOP ON ENVIRONMENTAL, ENERGY AND STRUCTURAL MONITORING SYSTEMS (EESMS 2013), 2013, : 51 - 56
  • [3] Structural health monitoring of a cable-stayed bridge using wireless smart sensor technology: data analyses
    Cho, Soojin
    Jo, Hongki
    Jang, Shinae
    Park, Jongwoong
    Jung, Hyung-Jo
    Yun, Chung-Bang
    Spencer, Billie F., Jr.
    Seo, Ju-Won
    SMART STRUCTURES AND SYSTEMS, 2010, 6 (5-6) : 461 - 480
  • [4] A multi-way data analysis approach for structural health monitoring of a cable-stayed bridge
    Alamdari, Mehrisadat Makki
    Nguyen Lu Dang Khoa
    Wang, Yang
    Samali, Bijan
    Zhu, Xinqun
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2019, 18 (01): : 35 - 48
  • [5] Structural health monitoring of a cable-stayed bridge using smart sensor technology: deployment and evaluation
    Jang, Shinae
    Jo, Hongki
    Cho, Soojin
    Mechitov, Kirill
    Rice, Jennifer A.
    Sim, Sung-Han
    Jung, Hyung-Jo
    Yun, Chung-Bang
    Spencer, Billie F., Jr.
    Agha, Gul
    SMART STRUCTURES AND SYSTEMS, 2010, 6 (5-6) : 439 - 459
  • [6] Entropy-based optimal sensor networks for structural health monitoring of a cable-stayed bridge
    Azarbayejani, M.
    El-Osery, A. I.
    Taha, M. M. Reda
    SMART STRUCTURES AND SYSTEMS, 2009, 5 (04) : 369 - 379
  • [7] Structural health monitoring methods of cables in cable-stayed bridge: A review
    Zhang, Lixiao
    Qiu, Guoyang
    Chen, Zhishou
    MEASUREMENT, 2021, 168
  • [8] Investigation concerning structural health monitoring of an instrumented cable-stayed bridge
    Ko, J. M.
    Ni, Y. Q.
    Zhou, H. F.
    Wang, J. Y.
    Zhou, X. T.
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2009, 5 (06) : 497 - 513
  • [9] HEALTH MONITORING AND EVALUATION SYSTEM FOR CABLE-STAYED BRIDGE USING COMPUTATIONAL SIMULATION AND SENSOR DATA
    Xie, Haibo
    Tian, Zhongchu
    Zheng, Wanggang
    Zhou, Yuxiang
    INTERNATIONAL SYMPOSIUM ON LIFE-CYCLE PERFORMANCE OF BRIDGES AND STRUCTURES, 2010, : 185 - 188
  • [10] Modal Analysis of a Cable-stayed Bridge
    Wei, Liuchuang
    Cheng, Heming
    Li, Jianyun
    INTERNATIONAL CONFERENCE ON ADVANCES IN COMPUTATIONAL MODELING AND SIMULATION, 2012, 31 : 481 - 486