Value of a Computer-aided Detection System Based on Chest Tomosynthesis Imaging for the Detection of Pulmonary Nodules

被引:5
|
作者
Yamada, Yoshitake [1 ,3 ]
Shiomi, Eisuke [1 ]
Hashimoto, Masahiro [1 ]
Abe, Takayuki [2 ]
Matsusako, Masaki [4 ]
Saida, Yukihisa [4 ]
Ogawa, Kenji [3 ]
机构
[1] Keio Univ, Sch Med, Shinjuku Ku, 35 Shinanoma Chi, Tokyo 1608582, Japan
[2] Keio Univ, Sch Med, Dept Prevent Med & Publ Hlth, Clin & Translat Res Ctr,Biostat Unit,Shinjuku Ku, 35 Shinanoma Chi, Tokyo 1608582, Japan
[3] Nippon Koukan Hosp, Dept Radiol, Kawasaki, Kanagawa, Japan
[4] St Lukes Int Hosp, Dept Radiol, Tokyo, Japan
关键词
DIGITAL TOMOSYNTHESIS; DIAGNOSTIC-PERFORMANCE; RADIOGRAPHY; OBSERVER; TOMOGRAPHY; MANAGEMENT;
D O I
10.1148/radiol.2017170405
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the value of a computer-aided detection (CAD) system for the detection of pulmonary nodules on chest tomosynthesis images. Materials and Methods: Fifty patients with and 50 without pulmonary nodules underwent both chest tomosynthesis and multidetector computed tomography (CT) on the same day. Fifteen observers (five interns and residents, five chest radiologists, and five abdominal radiologists) independently evaluated tomosynthesis images of 100 patients for the presence of pulmonary nodules in a blinded and randomized manner, first without CAD, then with the inclusion of CAD marks. Multidetector CT images served as the reference standard. Free-response receiver operating characteristic analysis was used for the statistical analysis. Results: The pooled diagnostic performance of 15 observers was significantly better with CAD than without CAD (figure of merit [FOM], 0.74 vs 0.71, respectively; P =.02). The average true-positive fraction and false-positive rate per all cases with CAD were 0.56 and 0.26, respectively, whereas those without CAD were 0.47 and 0.20, respectively. Subanalysis showed that the diagnostic performance of interns and residents was significantly better with CAD than without CAD (FOM, 0.70 vs 0.62, respectively; P =.001), whereas for chest radiologists and abdominal radiologists, the FOM with CAD values were greater but not significantly: 0.80 versus 0.78 (P =.38) and 0.74 versus 0.73 (P =.65), respectively. Conclusion: CAD significantly improved diagnostic performance in the detection of pulmonary nodules on chest tomosynthesis images for interns and residents, but provided minimal benefit for chest radiologists and abdominal radiologists. (C)RSNA, 2017
引用
收藏
页码:333 / 339
页数:7
相关论文
共 50 条
  • [41] Computer-Aided Detection of Lung Nodules: Influence of the Image Reconstruction Kernel for Computer-Aided Detection Performance
    Hwang, Jiyoung
    Chung, Myung Jin
    Bae, Younga
    Shin, Kyung Min
    Jeong, Sun Young
    Lee, Kyung Soo
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (01) : 31 - 34
  • [42] Temporal subtraction for the detection of solitary pulmonary nodules on chest radiographs: Evaluation of the first commercially available computer-aided diagnosis system
    Kozuka, T
    Johkoh, T
    Tomiyama, N
    Hamada, S
    Nakamura, H
    Fujiwara, K
    RADIOLOGY, 2000, 217 : 437 - 437
  • [43] Automatic detection of pulmonary nodules at spiral CT: clinical application of a computer-aided diagnosis system
    Dag Wormanns
    Martin Fiebich
    Mustafa Saidi
    Stefan Diederich
    Walter Heindel
    European Radiology, 2002, 12 : 1052 - 1057
  • [44] Automatic detection of pulmonary nodules at spiral CT: clinical application of a computer-aided diagnosis system
    Wormanns, D
    Fiebich, M
    Saidi, M
    Diederich, S
    Heindel, W
    EUROPEAN RADIOLOGY, 2002, 12 (05) : 1052 - 1057
  • [45] 3D skeletonization feature based computer-aided detection system for pulmonary nodules in CT datasets
    Zhang, Weihang
    Wang, Xue
    Li, Xuanping
    Chen, Junfeng
    COMPUTERS IN BIOLOGY AND MEDICINE, 2018, 92 : 64 - 72
  • [46] Effect of Clinical Experience of Chest Tomosynthesis on Detection of Pulmonary Nodules
    Zachrisson, S.
    Vikgren, J.
    Svalkvist, A.
    Johnsson, A. A.
    Boijsen, M.
    Flinck, A.
    Mansson, L. G.
    Kheddache, S.
    Bath, M.
    ACTA RADIOLOGICA, 2009, 50 (08) : 884 - 891
  • [47] Re: Clinical evaluation of a deep-learning-based computer-aided detection system for the detection of pulmonary nodules in a large teaching hospital
    Boon, I. S.
    Teo, R. P. J.
    Yap, M. H.
    Lim, J. S.
    Goh, H. L.
    Boon, C. S.
    Yongg, T. P. T. Au
    CLINICAL RADIOLOGY, 2022, 77 (02) : 156 - 157
  • [48] Autonomous Detection of Solitary Pulmonary Nodules on CT Images for Computer-Aided Diagnosis
    Wei Ying
    Jia Tong
    Lin Ming-xiu
    2011 CHINESE CONTROL AND DECISION CONFERENCE, VOLS 1-6, 2011, : 4054 - 4059
  • [49] Evaluation of a method of computer-aided detection (CAD) of pulmonary nodules at computed tomography
    Foti, G.
    Faccioli, N.
    D'Onofrio, M.
    Contro, A.
    Milazzo, T.
    Mucelli, R. Pozzi
    RADIOLOGIA MEDICA, 2010, 115 (06): : 950 - 961