Value of a Computer-aided Detection System Based on Chest Tomosynthesis Imaging for the Detection of Pulmonary Nodules

被引:5
|
作者
Yamada, Yoshitake [1 ,3 ]
Shiomi, Eisuke [1 ]
Hashimoto, Masahiro [1 ]
Abe, Takayuki [2 ]
Matsusako, Masaki [4 ]
Saida, Yukihisa [4 ]
Ogawa, Kenji [3 ]
机构
[1] Keio Univ, Sch Med, Shinjuku Ku, 35 Shinanoma Chi, Tokyo 1608582, Japan
[2] Keio Univ, Sch Med, Dept Prevent Med & Publ Hlth, Clin & Translat Res Ctr,Biostat Unit,Shinjuku Ku, 35 Shinanoma Chi, Tokyo 1608582, Japan
[3] Nippon Koukan Hosp, Dept Radiol, Kawasaki, Kanagawa, Japan
[4] St Lukes Int Hosp, Dept Radiol, Tokyo, Japan
关键词
DIGITAL TOMOSYNTHESIS; DIAGNOSTIC-PERFORMANCE; RADIOGRAPHY; OBSERVER; TOMOGRAPHY; MANAGEMENT;
D O I
10.1148/radiol.2017170405
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the value of a computer-aided detection (CAD) system for the detection of pulmonary nodules on chest tomosynthesis images. Materials and Methods: Fifty patients with and 50 without pulmonary nodules underwent both chest tomosynthesis and multidetector computed tomography (CT) on the same day. Fifteen observers (five interns and residents, five chest radiologists, and five abdominal radiologists) independently evaluated tomosynthesis images of 100 patients for the presence of pulmonary nodules in a blinded and randomized manner, first without CAD, then with the inclusion of CAD marks. Multidetector CT images served as the reference standard. Free-response receiver operating characteristic analysis was used for the statistical analysis. Results: The pooled diagnostic performance of 15 observers was significantly better with CAD than without CAD (figure of merit [FOM], 0.74 vs 0.71, respectively; P =.02). The average true-positive fraction and false-positive rate per all cases with CAD were 0.56 and 0.26, respectively, whereas those without CAD were 0.47 and 0.20, respectively. Subanalysis showed that the diagnostic performance of interns and residents was significantly better with CAD than without CAD (FOM, 0.70 vs 0.62, respectively; P =.001), whereas for chest radiologists and abdominal radiologists, the FOM with CAD values were greater but not significantly: 0.80 versus 0.78 (P =.38) and 0.74 versus 0.73 (P =.65), respectively. Conclusion: CAD significantly improved diagnostic performance in the detection of pulmonary nodules on chest tomosynthesis images for interns and residents, but provided minimal benefit for chest radiologists and abdominal radiologists. (C)RSNA, 2017
引用
收藏
页码:333 / 339
页数:7
相关论文
共 50 条
  • [21] CLINICAL APPLICATION OF THIN SECTION CHEST CT WITH COMPUTER-AIDED DETECTION SYSTEM FOR THE DETECTION OF SMALL METASTATIC NODULES IN PULMONARY METASTASECTOMY.
    Kim, Hye-Seon
    Kang, Chang Hyun
    Goo, Jin Mo
    Park, In Kyu
    Kim, Young Tae
    JOURNAL OF THORACIC ONCOLOGY, 2013, 8 : S683 - S683
  • [22] A Computer-Aided Detection System for Digital Chest Radiographs
    Manuel Carrillo-de-Gea, Juan
    Garcia-Mateos, Gines
    Luis Fernandez-Aleman, Jose
    Luis Hernandez-Hernandez, Jose
    JOURNAL OF HEALTHCARE ENGINEERING, 2016, 2016
  • [23] Computer-Aided Detection of Pulmonary Pathology in Pediatric Chest Radiographs
    Mouton, Andre
    Pitcher, Richard D.
    Douglas, Tania S.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2010, PT III, 2010, 6363 : 619 - +
  • [24] Computer-aided Detection Improves Detection of Pulmonary Nodules in Chest Radiographs beyond the Support by Bone-suppressed Images
    Schalekamp, Steven
    van Ginneken, Bram
    Koedam, Emmeline
    Snoeren, Miranda M.
    Tiehuis, Audrey M.
    Wittenberg, Rianne
    Karssemeijer, Nico
    Schaefer-Prokop, Cornelia M.
    RADIOLOGY, 2014, 272 (01) : 252 - 261
  • [25] Temporal subtraction for detection of solitary pulmonary nodules on chest radiographs: Evaluation of a commercially available computer-aided diagnosis system
    Johkoh, T
    Kozuka, T
    Tomiyama, N
    Hamada, S
    Honda, O
    Mihara, N
    Koyama, M
    Tsubamoto, M
    Maeda, M
    Nakamura, H
    Saki, H
    Fujiwara, K
    RADIOLOGY, 2002, 223 (03) : 806 - 811
  • [26] A New Pulmonary Nodules Computer-aided Detection System in Chest CT Images Based on Adaptive Fuzzy C-Means Technology
    Wang, Jinke
    Cheng, Yuanzhi
    2015 7TH INTERNATIONAL CONFERENCE ON INTELLIGENT HUMAN-MACHINE SYSTEMS AND CYBERNETICS IHMSC 2015, VOL I, 2015, : 514 - 517
  • [27] Improved detection of lung nodules on chest radiographs using a commercial computer-aided diagnosis system
    Kakeda, S
    Moriya, J
    Sato, H
    Aoki, T
    Watanabe, H
    Nakata, H
    Oda, N
    Katsuragawa, S
    Yamamoto, K
    Doi, K
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (02) : 505 - 510
  • [28] A computer-aided diagnosis system for detection of lung nodules in chest radiographs with an evaluation on a public database
    Schilham, AMR
    van Ginneken, B
    Loog, M
    MEDICAL IMAGE ANALYSIS, 2006, 10 (02) : 247 - 258
  • [29] A Computer-Aided Detection System for the Detection of Lung Nodules Based on 3D-ResNet
    Ning, Jiaxu
    Zhao, Haitong
    Lan, Lei
    Sun, Peng
    Feng, Yunfei
    APPLIED SCIENCES-BASEL, 2019, 9 (24):
  • [30] New methods for using computer-aided detection information for the detection of lung nodules on chest radiographs
    Schalekamp, S.
    van Ginneken, B.
    Heggelman, B. G. F.
    Imhof-Tas, M.
    Somers, I.
    Brink, M.
    Spee, M.
    Schaefer-Prokop, C. M.
    Karssemeijer, N.
    BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1036):