Evaluation of Optic Nerve Sheath Diameter and Transcranial Doppler As Noninvasive Tools to Detect Raised Intracranial Pressure in Children

被引:19
|
作者
Sharawat, Indar Kumar [1 ]
Kasinathan, Ananthanarayanan [2 ]
Bansal, Arun [3 ]
Sahu, Jitendra Kumar [4 ]
Sodhi, Kushaljit Singh [5 ]
Dogra, Mangat Ram [6 ]
Sankhyan, Naveen [4 ]
机构
[1] All India Inst Med Sci, Dept Pediat, Pediat Neurol Div, Rishikesh, India
[2] Jawaharlal Inst Postgrad Med Educ & Res, Dept Pediat, Pondicherry, India
[3] Postgrad Inst Med Educ & Res, Dept Pediat, Chandigarh, India
[4] Postgrad Inst tute Med Educ & Res, Dept Pediat, Pediat Neurol Unit, Chandigarh, India
[5] Postgrad Inst Med Educ & Res, Dept Radiodiag & Imaging, Chandigarh, India
[6] Postgrad Inst Med Educa tion & Res, Dept Ophthalmol, Chandigarh, India
关键词
intracranial hemodynamics; intracranial pressure monitoring; optic nerve sheath diameter; optic nerve sheath ultrasonography; raised intracranial pressure; transcranial Doppler; PULSATILITY INDEX; SONOGRAPHY; ICP; EDEMA; ONSD;
D O I
10.1097/PCC.0000000000002523
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: To compare the diagnostic accuracy of the ultrasonography-guided optic nerve sheath diameter with transcranial Doppler-guided middle cerebral artery flow indices against the gold standard invasive intraparenchymal intracranial pressure values in children. Design: A single-center prospective cohort study. Setting: PICU of a tertiary care teaching hospital in North India. Patients: Eligible children (2-12 yr) are admitted to ICU and are undergoing intracranial pressure monitoring using an intraparenchymal catheter. Observations with a parallel measured intracranial pressure greater than or equal to 20 mm Hg were included as case-observations. Children with an invasive intracranial pressure of less than or equal to 15 mm Hg were taken as neurologic-control-observations and healthy children served as healthy-control-observations. Interventions: The horizontal and vertical diameters of the optic nerves were measured, and averages were calculated and compared. Middle cerebral artery flow indices (pulsatility index and resistive index) were measured bilaterally and averages were calculated and compared in the three groups. Twenty-two measurements of optic nerve sheath diameter were assessed by two different observers in quick succession for interrater reliability. Measurements and Main Results: A total of 148 observations were performed in 30 children. Four observations were excluded (intracranial pressure between 16 and 19 mm Hg). Of the 144 observations, 106 were case-observations and 38 were neurologic-control-observations. Additional 66 observations were healthy-control-observations. The mean optic nerve sheath diameter was 5.71 +/- 0.57 mm in the case-observations group, 4.21 +/- 0.66 mm in the neurologic-control-observations group, and 3.71 +/- 0.27 mm in the healthy-control-observations group (p < 0.001 for case-observations vs neurologic-control-observations/healthy-control-observations). The mean pulsatility index in case-observations was 0.92 +/- 0.41 compared with controls 0.79 +/- 0.22 (p = 0.005) and the mean resistive index was 0.56 +/- 0.13 in case-observations compared with 0.51 +/- 0.09 (p = 0.007) in controls (neurologic-control-observations and healthy-control-observations). For the raised intracranial pressure defined by intracranial pressure greater than or equal to 20 mm Hg, the area under the curve for optic nerve sheath diameter was 0.976, while it was 0.571 for pulsatility index and 0.579 for resistive index. Furthermore, the optic nerve sheath diameter cutoff of 4.0 mm had 98% sensitivity and 75% specificity for raised intracranial pressure, while the pulsatility index value of 0.51 had 89% sensitivity and 10% specificity by middle cerebral artery flow studies. The sensitivity and specificity of 0.40 resistive index value in the raised intracranial pressure were 88% and 11%, respectively. Kendall correlation coefficient between intracranial pressure and optic nerve sheath diameter, pulsatility index, and resistive index was 0.461, 0.148, and 0.148, respectively. The Pearson correlation coefficient between two observers for optic nerve sheath diameter, pulsatility index, and resistive index was 0.98, 0.914, and 0.833, respectively. Conclusions: Unlike transcranial Doppler-guided middle cerebral artery flow indices, ultrasonography-guided optic nerve sheath diameter was observed to have a good diagnostic accuracy in identifying children with an intracranial pressure of greater than or equal to 20 mm Hg.
引用
收藏
页码:959 / 965
页数:7
相关论文
共 50 条
  • [21] OPTIC NERVE SHEATH DIAMETER CHANGES IN CHILDREN WITH VARYING DEGREES OF INTRACRANIAL PRESSURE
    Riggs, Becky
    Dean, Nathan
    Hwang, Misun
    Trimboli-Heidler, Carmelina
    Hunt, Megan
    Thimm, Matthew
    Repka, Michael
    Cohen, Joanna
    CRITICAL CARE MEDICINE, 2020, 48
  • [22] Correlation of optic nerve and optic nerve sheath diameter with intracranial pressure in pigs
    Mija, R.
    Zubak, I
    Schuetz, A.
    Glas, M.
    Fung, C.
    Jakob, S. M.
    Beck, J.
    Z'Graggen, W. J.
    Bloch, Andreas
    PLOS ONE, 2020, 15 (02):
  • [23] Reliability of Assessing Non-severe Elevation of Intracranial Pressure Using Optic Nerve Sheath Diameter and Transcranial Doppler Parameters
    Chen, Li-min
    Wang, Li-juan
    Shi, Lin
    Chen, Hong-xiu
    Jiang, Xiao-han
    Chen, Qian-qian
    Xing, Ying-qi
    FRONTIERS IN NEUROLOGY, 2019, 10
  • [24] Ultrasonographic optic nerve sheath diameter as a noninvasive marker for intracranial hypotension
    Li-juan Wang
    Zhang, Ying
    Li, Cong
    Liu, Ying
    Ya-nan Dong
    Cui, Li
    Ying-qi Xin
    THERAPEUTIC ADVANCES IN NEUROLOGICAL DISORDERS, 2022, 15
  • [25] Noninvasive and quantitative intracranial pressure estimation using ultrasonographic measurement of optic nerve sheath diameter
    Wang, Li-juan
    Yao, Yan
    Feng, Liang-shu
    Wang, Yu-zhi
    Zheng, Nan-nan
    Feng, Jia-chun
    Xing, Ying-qi
    SCIENTIFIC REPORTS, 2017, 7
  • [26] Noninvasive and quantitative intracranial pressure estimation using ultrasonographic measurement of optic nerve sheath diameter
    Li-juan Wang
    Yan Yao
    Liang-shu Feng
    Yu-zhi Wang
    Nan-nan Zheng
    Jia-chun Feng
    Ying-qi Xing
    Scientific Reports, 7
  • [27] Optic Nerve Sheath Diameter Ultrasound: Optic Nerve Growth Curve and its Application to Detect Intracranial Hypertension in Children
    De Bernardo, Maddalena
    Vitiello, Livio
    Rosa, Nicola
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 208 : 438 - 438
  • [28] Optic Nerve Sheath Diameter Ultrasound: Optic Nerve Growth Curve and Its Application to Detect Intracranial Hypertension in Children
    Fontanel, Liviana
    Pensiero, Stefano
    Ronfani, Luca
    Rosolen, Valentina
    Barbi, Egidio
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 208 : 421 - 428
  • [29] The quantitative evaluation of intracranial pressure by optic nerve sheath diameter/eye diameter CT measurement
    Bekerman, Inessa
    Sigal, Tal
    Kimiagar, Itzhak
    Ben Ely, Anna
    Vaiman, Michael
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (12): : 2336 - 2342
  • [30] Measuring Optic Nerve Sheath Diameter as a Proxy for Intracranial Pressure
    Hoffman, Robert S.
    JAMA OPHTHALMOLOGY, 2018, 136 (11) : 1309 - 1309