BIPVT systems for residential applications: An energy and economic analysis for European climates

被引:99
作者
Buonomano, Annamaria [1 ]
Calise, Francesco [1 ]
Palombo, Adolfo [1 ]
Vicidomini, Maria [1 ]
机构
[1] Univ Naples Federico II, DII, Ple Tecchio 80, I-80125 Naples, Italy
关键词
Dynamic energy performance simulation; Solar energy; BIPVT; Building Integrated Solar Thermal Systems (BISTS); PHOTOVOLTAIC-THERMAL COLLECTORS; DYNAMIC SIMULATION; PERFORMANCE; BUILDINGS; DESIGN; CONFIGURATIONS; IMPLEMENTATION; CONCENTRATOR; EFFICIENCIES; BEHAVIOR;
D O I
10.1016/j.apenergy.2016.02.145
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper analyses the energy and economic performance of roof and/or facades Building Integrated flat plate PhotoVoltaic and Thermal (BIPVT) collectors for residential applications. Aim of the analysis is to assess the active and passive effects due to the building integration of solar technologies on the building energy consumptions. In particular, a comparison among innovative building-plant system configurations, based on BIPVT collectors for the simultaneous production of electricity, thermal energy, and domestic hot water, is carried out. The simulation models of the proposed system layouts are designed and implemented in TRNSYS simulation environment for the dynamic assessment of their energy and economic performance. By means of the developed simulation model, the occurring summer and winter building passive energy effects due to the PVT building integration are also analysed. Several case studies are developed by modelling a representative multi-storey residential building and by taking into account different European climates. For such case studies a suitable energy parametric analysis is performed by varying the thermal resistances and capacitances of the building envelope. By the simulation results interesting design and economic feasibility guidelines are obtained. In particular, by varying the weather location and the building-plant configuration, the adoption of BIPVT panels produces a decrease of the primary energy demands from 67% to 89%. The passive effects of the BIPVT system in both the winter and summer season are also assessed for all the investigated climate zones. The calculated economic profitability resulted slightly better for roof BIPVT panels than for roof and facade applications. For the investigated case studies, the pay back periods appear quite long, varying from 11 years for South European weather zones to 20 for North European ones. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1411 / 1431
页数:21
相关论文
共 59 条
  • [1] Double skin facades (DSF) and building integrated photovoltaics (BIPV): A review of configurations and heat transfer characteristics
    Agathokleous, Rafaela A.
    Kalogirou, Soteris A.
    [J]. RENEWABLE ENERGY, 2016, 89 : 743 - 756
  • [2] Optimizing the energy and exergy of building integrated photovoltaic thermal (BIPVT) systems under cold climatic conditions
    Agrawal, Basant
    Tiwari, G. N.
    [J]. APPLIED ENERGY, 2010, 87 (02) : 417 - 426
  • [3] [Anonymous], EN CLIM CHANG WORLD
  • [4] Aschaber J., 2009, 17 TRNSYS, P1983
  • [5] A prototype photovoltaic/thermal system integrated with transpired collector
    Athienitis, Andreas K.
    Bambara, James
    O'Neill, Brendan
    Faille, Jonathan
    [J]. SOLAR ENERGY, 2011, 85 (01) : 139 - 153
  • [6] A general approach toward building integrated photovoltaic systems and its implementation barriers: A review
    Azadian, Farshad
    Radzi, M. A. M.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 22 : 527 - 538
  • [7] Building integrated solar thermal collectors - A review
    Buker, Mahmut Sami
    Riffat, Saffa B.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 51 : 327 - 346
  • [8] Performance evaluation and techno-economic analysis of a novel building integrated PV/T roof collector: An experimental validation
    Buker, Mahmut Sami
    Mempouo, Blaise
    Riffat, Saffa B.
    [J]. ENERGY AND BUILDINGS, 2014, 76 : 164 - 175
  • [9] Dynamic energy performance analysis: Case study for energy efficiency retrofits of hospital buildings
    Buonomano, Annamaria
    Calise, Francesco
    Ferruzzi, Gabriele
    Palombo, Adolfo
    [J]. ENERGY, 2014, 78 : 555 - 572
  • [10] A novel renewable polygeneration system for hospital buildings: Design, simulation and thermo-economic optimization
    Buonomano, Annamaria
    Calise, Francesco
    Ferruzzi, Gabriele
    Vanoli, Laura
    [J]. APPLIED THERMAL ENGINEERING, 2014, 67 (1-2) : 43 - 60