X-ray beam splitting design for concurrent imaging at hard X-ray FELs and synchrotron facilities

被引:1
作者
Oberta, P. [1 ,2 ]
Mokso, R. [3 ]
机构
[1] Acad Sci Czech Republ, Vvi, Inst Phys, CZ-18221 Prague 8, Czech Republic
[2] Rigaku Corp, CZ-14221 Prague 4, Czech Republic
[3] Paul Scherrer Inst, Swiss Light Source, CH-5232 Villigen, Switzerland
关键词
Diffractive-refractive optics; Hard X-ray FEL; X-ray imaging; OPTICS;
D O I
10.1016/j.nima.2013.06.102
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new configuration of diffractive-refractive optics for beam splitting is investigated. The set-up can be applied to perform imaging with two beams simultaneously. It brings advantages toward dynamic studies using image guided diffraction or fluorescence spectroscopy. The optimal energy range of operation for the beam-splitter is between 7 keV and 24 keV, reaching best efficiency at an energy of 10 keV. Due to the long focusing distances (several tens of meters) created by the diffractive-refractive optics and the higher refraction efficiency in the softer energy range, the presented set-ups are ideal for hard X-ray FEL sources. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:85 / 89
页数:5
相关论文
共 12 条
[1]  
CDR, 2011, XRAY OPT BEAM TRANSP
[2]   Diffractive-refractive optics in the Laue case: first experiment [J].
Hrdy, J. ;
Mocella, V. ;
Oberta, P. ;
Peverini, L. ;
Potlovskiy, K. .
JOURNAL OF SYNCHROTRON RADIATION, 2006, 13 :392-396
[3]   X-ray inclined lens [J].
Hrdy, J .
JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 :1206-1210
[4]   Diffractive-refractive optics: (+,-,-,+) X-ray crystal monochromator with harmonics separation [J].
Hrdy, Jaromir ;
Mikulik, Petr ;
Oberta, Peter .
JOURNAL OF SYNCHROTRON RADIATION, 2011, 18 :299-301
[5]   Diffractive-refractive optics: X-ray splitter [J].
Hrdy, Jaromir .
JOURNAL OF SYNCHROTRON RADIATION, 2010, 17 :129-131
[6]   Diffractive-refractive optics: X-ray collimator [J].
Hrdy, Jaromir ;
Oberta, Peter .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (07)
[7]   Combined use of hard X-ray phase contrast imaging and X-ray fluorescence microscopy for sub-cellular metal quantification [J].
Kosior, Ewelina ;
Bohic, Sylvain ;
Suhonen, Heikki ;
Ortega, Richard ;
Deves, Guillaume ;
Carmona, Asuncion ;
Marchi, Florence ;
Guillet, Jean Francois ;
Cloetens, Peter .
JOURNAL OF STRUCTURAL BIOLOGY, 2012, 177 (02) :239-247
[8]   Nanoscale zoom tomography with hard x rays using Kirkpatrick-Baez optics [J].
Mokso, R. ;
Cloetens, P. ;
Maire, E. ;
Ludwig, W. ;
Buffiere, J. -Y. .
APPLIED PHYSICS LETTERS, 2007, 90 (14)
[9]   A proof-of-principle experiment of a novel harmonics separation optics for synchrotron facilities [J].
Oberta, P. ;
Hrdy, J. ;
Mikulik, P. .
JOURNAL OF SYNCHROTRON RADIATION, 2012, 19 :1012-1014
[10]   The SwissFEL facility and its preliminary optics beamline layout [J].
Oberta, P. ;
Flechsig, U. ;
Abela, R. .
ADVANCES IN X-RAY FREE-ELECTRON LASERS: RADIATION SCHEMES, X-RAY OPTICS, AND INSTRUMENTATION, 2011, 8078