摘要
The objective of this Study is to develop methods to dynamically select EEG channels to reduce power consumption in seizure detection while maintaining detection accuracy. A method is proposed whereby a number of primary screening channels are predefined. Depending on the classification results of those channels, further channels are selected for analysis. This method provides savings in computational complexity of 43%. A further method called idling is then proposed which increases the computational saving to 75%. The performance of a location-independent, decision-based method is used for comparison. The proposed method achieves better computational savings for the same performance than the decision-based method. The decision-based method was capable of higher overall computational savings, but with a reduction in seizure detection performance. Each method was also implemented with the REACT algorithm on a Blackfin microprocessor and the average power measured. The proposed methods gave a power saving of up to 47% with no reduction in detection performance. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1206 / 1215
页数:10
相关论文
共 24 条
[1]   A wavelet-packets based algorithm for EEG signal compression [J].
Cárdenas-Barrera, JL ;
Lorenzo-Ginori, JV ;
Rodríguez-Valdivia, E .
MEDICAL INFORMATICS AND THE INTERNET IN MEDICINE, 2004, 29 (01) :15-27
[2]   Toward Online Data Reduction for Portable Electroencephalography Systems in Epilepsy [J].
Casson, Alexander J. ;
Rodriguez-Villegas, Esther .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (12) :2816-2825
[3]   An evaluation of automated neonatal seizure detection methods [J].
Faul, S ;
Boylan, G ;
Connolly, S ;
Marnane, L ;
Lightbody, G .
CLINICAL NEUROPHYSIOLOGY, 2005, 116 (07) :1533-1541
[4]  
Faul S., 2010, patent ID, Patent No. [W02010/115939A2, 2010115939, WO/2010/115939]
[5]  
Faul S.D., 2007, THESIS U COLL CORK
[6]  
Faul S.D., 2010, P 32 ANN INT C IEEE, P6365
[7]   Age-independent Seizure Detection [J].
Faul, Stephen ;
Temko, Andriy ;
Marnane, William .
2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, :6612-6615
[8]   How Long Does It Take to Make an Accurate Diagnosis in an Epilepsy Monitoring Unit? [J].
Friedman, David E. ;
Hirsch, Lawrence J. .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2009, 26 (04) :213-217
[9]   Classifier models and architectures for EEG-based neonatal seizure detection [J].
Greene, B. R. ;
Marnane, W. P. ;
Lightbody, G. ;
Reilly, R. B. ;
Boylan, G. B. .
PHYSIOLOGICAL MEASUREMENT, 2008, 29 (10) :1157-1178
[10]  
GREENE BR, 2008, P 30 INT C IEEE ENG, P915