Optimal configuration for distributed generations in micro-grid system considering diesel as the main control source

被引:0
作者
Li, Yanbin [1 ]
Chen, Xiang [1 ]
Xiao, Junming [1 ]
Wei, Xuehui [1 ]
机构
[1] Zhongyuan Univ Technol, Sch Elect & Informat Engn, Zhengzhou 450007, Peoples R China
来源
2014 INTERNATIONAL CONFERENCE ON ADVANCED MECHATRONIC SYSTEMS (ICAMECHS) | 2014年
关键词
distributed generations; renewable generations; micro grid; HOMER; genetic algorithm; ENERGY-CONVERSION SYSTEM; SIZE OPTIMIZATION; BATTERY STORAGE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper purposes an optimal configuration of the distributed hybrid renewable generations based the stand-alone micro-grid system, considering the diesel as the main control source. Due to the natural sources and load of user changes randomly and the nonlinearity of the power output by renewable generations, an intelligent optimization method based improved genetic algorithm and the control strategy were discussed with the hybrid renewable system which the model form is windPV-(Photovoltaic)-diesel-battery. The instance analysis comparing the optimization result of the hybrid system based on HOMER and improved GA(Genetic Algorithm) method on MATLAB. The simulation result of the optimal configuration showed the new hybrid renewable system would improve the power supply situation which decreased the cost of energy greatly compared with the conventional form of power supply system which was operated only by diesel. And the conclusion of the comparing result between HOMER and improved GA method showed the advantages of the strategy for the diesel as main control sources.
引用
收藏
页码:552 / 556
页数:5
相关论文
共 12 条
[1]  
Asato B., 2010, EL MACH SYST ICEMS 2, P1869
[2]   Size optimization of a PV/wind hybrid energy conversion system with battery storage using response surface methodology [J].
Ekren, Orhan ;
Ekren, Banu Yetkin .
APPLIED ENERGY, 2008, 85 (11) :1086-1101
[3]   Size optimization of a PV/wind hybrid energy conversion system with battery storage using simulated annealing [J].
Ekren, Orhan ;
Ekren, Banu Y. .
APPLIED ENERGY, 2010, 87 (02) :592-598
[4]   Break-even analysis and size optimization of a PV/wind hybrid energy conversion system with battery storage - A case study [J].
Ekren, Orhan ;
Ekren, Banu Y. ;
Ozerdem, Baris .
APPLIED ENERGY, 2009, 86 (7-8) :1043-1054
[5]  
Lambert T, 2006, INTEGRATION OF ALTERNATIVE SOURCES OF ENERGY, P379
[6]   Implementation of an Intelligent Reconfiguration Algorithm for an Electric Ship's Power System [J].
Mitra, Pinaki ;
Venayagamoorthy, Ganesh Kumar .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2011, 47 (05) :2292-2300
[7]  
Qais A, 2013, PROCEEDINGS OF THE 2013 IEEE 7TH INTERNATIONAL POWER ENGINEERING AND OPTIMIZATION CONFERENCE (PEOCO2013), P714
[8]   Techno-economical optimization of hybrid pv/wind/battery system using Neuro-Fuzzy [J].
Rajkumar, R. K. ;
Ramachandaramurthy, V. K. ;
Yong, B. L. ;
Chia, D. B. .
ENERGY, 2011, 36 (08) :5148-5153
[9]  
Razak Nurul Arina bte Abdull, 2010, 2010 4th International Power Engineering and Optimization Conference (PEOCO 2010), P495, DOI 10.1109/PEOCO.2010.5559240
[10]   Feasibility study of a wind-pv-diesel hybrid power system for a village [J].
Rehman, Shafiqur ;
Alam, Md. Mahbub ;
Meyer, J. P. ;
Al-Hadhrami, Luai M. .
RENEWABLE ENERGY, 2012, 38 (01) :258-268